Records from 1991 to 2004. Most recent: inspection, 23 September 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
23 September 2004
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2202888
2 July 2003
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1832385
1 July 2003
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1854223
1 May 2003
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1784226
13 March 2003
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739820
2 May 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1611949
11 April 2002
Re-Inspection · Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1492429
23 March 2001
Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1423580
24 January 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 825274
25 September 2000
Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1406792
16 June 2000
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1051234
10 May 2000
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1361492
26 May 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 808932
25 May 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 805532
4 May 1999
Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432131
20 May 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1127171
7 April 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470711
15 April 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1458410
10 April 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405890
10 April 1995
Re-Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1163652
3 May 1994
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 858047
20 April 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 830966
14 April 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1266641
4 August 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 937180
23 July 1991
Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1308837
Construction/Loadline › Penetrations
Issued 13 March 2003
Resolved
Replace aft drive shaft boot prior to carrying passengers. Conduct satisfactory watertest, witnessed by two person and fax results to Marine Safety Office St. Louis Att. [name withheld] DESC: Pipe Flange
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 11 April 2002
Resolved
Replace all expired items in first kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 7 May 2002
Electrical › Electrical Distribution System (service)
Issued 11 April 2002
Resolved
Update fuse panel index according to plans. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Due 11 May 2002
Resolved 7 May 2002
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 April 2002
Resolved
Make free board marks more visible.
Condition: Improper Installation
Due 11 May 2002
Resolved 11 April 2002
Construction/Loadline
Issued 23 March 2001
Resolved
REMOVE ALL OIL AND WATER FROM BILGES.
Condition: Unknown
Due 24 June 2001
Resolved 7 May 2002
Engineering
Issued 23 March 2001
Resolved
INSTALL PROPER FUEL HOSE OR HARD PIPE FUEL LINE AT THE FUEL PUMP.
Condition: Unknown
Due 24 June 2001
Resolved 7 May 2002
Lifesaving
Issued 10 May 2000
Resolved
RELABEL ALL PFD'S AND LIFE RING.
Condition: Unknown
Due 10 May 2000
Resolved 10 May 2000
Documentation
Issued 10 May 2000
Resolved
PROVIDE PROOF OF TRAINING PER 46 CFR 185.420
Condition: Unknown
Due 10 May 2000
Resolved 10 May 2000
Construction/Loadline
Issued 4 May 1999
Resolved
Install High Level Bilge alarm.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 4 May 1999
Resolved
Prior to entering the water, ensure all side curtains are up.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 4 May 1999
Resolved
Post life jacket donning instructions.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 4 May 1999
Resolved
Install Coast Guard approved First Aid kit.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Construction/Loadline
Issued 4 May 1999
Resolved
Carry no passengers until hull damage in way of bilge pump drive is properly repaired and c;hain is correctly adjusted.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Construction/Loadline
Issued 4 May 1999
Resolved
Carry no passengers until forward drive shaft, aft seal has been renewed and tested.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Construction/Loadline
Issued 7 April 1998
Resolved
Ensure bilges are free of slop oil.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Engineering
Issued 7 April 1998
Resolved
Install tachometer at operators station.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Fire Fighting
Issued 7 April 1998
Resolved
Provide three 2 1/2 gallon fire buckets.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998