WISBY BARBADOS

WISBY BARBADOS is a 1991 tank ship. The Coast Guard has recorded 26 inspections since 1991, most recently in June 2002, along with 21 deficiencies.

Records from 1991 to 2002. Most recent: inspection, 17 June 2002.

Built
1991
Last inspected
17 June 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8914192 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
365428
Flag
BAHAMAS, THE
—
Maury page id
psix-365428

Inspections, by type

…with no type recorded14
Years with a record 12 calendar years (1991–2002)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4094 - Regulatory (Subpart C or D), Gross Ton
2129 - Regulatory (Subpart C or D), Net Ton
8647 - Displacement, Ton
6330 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

17 June 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1631892
17 May 2002 MARPOL Annex I Examination · Tank Vessel Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1617906
5 April 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 288745
5 April 2001 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1062383
28 March 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 276147
28 March 2000 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1047332
7 June 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 429287
9 February 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 425416
9 February 1999 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 793222
11 March 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 413611
11 February 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 412725
11 February 1998 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1113381
17 January 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 399425
31 July 1996 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 393769
10 January 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 386755
3 January 1996 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 877124
19 May 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 378422
8 January 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 373856
8 January 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1387684
18 November 1994 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1179016
25 August 1994 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 441298
25 October 1993 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1455165
16 December 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1140191
30 October 1992 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1362658
10 July 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 457549
3 August 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1245782

Deficiency record · 21

Deck/Cargo › Ballast
Issued 17 May 2002 Resolved
Make permanent repairs to ballast pipe line and ballast cross over line to the satisfaction of class by 21May02. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2002
Resolved 17 May 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 17 May 2002 Resolved
Make permanent repairs to #1,4,&5 hydraulic framo lines to the satisfaction of class by 21May02 LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2002
Resolved 17 May 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 17 May 2002 Resolved
Prior to use in U.S. waters, soft patches on heat exchanger to be permanently repaired to the satisfaction of class. LEGACY COMPONENT DESC: Cargo Pump
Action required: 705 - Other - as specified
Due 21 May 2002
Resolved 17 May 2002
Engineering › Bilge Water Management System
Issued 17 May 2002 Resolved
Suction keel duct valve to be replaced by 21May02 to the satisfaction of class by 21May02. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2002
Resolved 17 May 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 17 May 2002 Resolved
Diesel starboard aft flame screen to be installed by 21May02. LEGACY COMPONENT DESC: Flame Screens
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2002
Resolved 17 May 2002
Deck/Cargo
Issued 9 February 1999 Resolved
Repair fractured expansion joint on tank washing line, port side, at the manifold.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Deck/Cargo
Issued 11 February 1998 Resolved
PROPERLY FLANGE TRANSFER MANIFOLD OF FLOATING HOSE
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Fire Fighting
Issued 17 January 1997 Resolved
FIRE EXTINGUISHERS IN ENGINE ROOM MISSING SEALS, CORRECT TO SATISFACTION OFCLASS SOCIETY, PRIOR TO NEXT U.S. PORT. SOLAS 74 (AMENDED) REG II-2/21.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Fire Fighting
Issued 17 January 1997 Resolved
PAINT LOCKER DOES NOT HAVE FIXED FIRE-EXTINGUISHING ARRANGEMENT, CORRECT TOSATISFACTION OF CLASS SOCIETY PRIOR TO NEXT U.S. PORT. SOLAS 74 AMMENDED REG II-2/18.7.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Electrical
Issued 17 January 1997 Resolved
PRIOR TO NEXT U.S. PORT, MAKE REPAIRS TO EMERGENCY GENERATOR RADIATOR TO SATISFACTION OF CLASS SOCIETY. SOLAS 74 CHAP II-1 REG 43.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Fire Fighting
Issued 17 January 1997 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE ADEQUATE SUPPORT TO FIREMAIN IN WAY OF FLEXIBLE EXPANSION COUPLING LOCATED AT ISOLATION VALVE TO SATISFACTION_x001C_ OF CLASS SOCIETY. SOLAS 74 REG II/2.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Deck/Cargo
Issued 17 January 1997 Resolved
PRIOR TO NEXT U.S. PORT, DEMONSTRATE PROPER OPERATION OF ODME TO SATISFACTION OF CLASS SOCIETY. MARPOL ANNEX I REGULATION 15.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Deck/Cargo
Issued 17 January 1997 Resolved
PROVE PROPER MANUAL OPERATION OF NO. 1S & 2S P/V VALVES SATISFACTION OF CLASS SOCIETY PRIOR TO NEXT U.S. PORT. 33 CFR 156.170(C)(2).
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Navigation
Issued 10 January 1996 Resolved
NO U.S. COAST PILOT, (1994/EDIT.25) CORRECTIONS AS REQUIRED BY 33 CFR _x001C_ 164(a.)
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Accommodation/Occupational Safety
Issued 8 January 1995 Resolved
HOSPITAL SPACE BATHROOM HAS PROVISION CARGO IN IT._x001C_ 33 C.F.R. 142.84
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Engineering
Issued 8 January 1995 Resolved
VALVE ON SEWAGE LINE IS LEAKING INSIDE THE ENGINEROOM.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Documentation
Issued 8 January 1995 Resolved
OIL TRANSFER PROCEDURES ARE MISSING SOME ITEMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1995
Resolved 17 January 1995
Construction/Loadline
Issued 30 October 1992 Resolved
Provide mechinical means of securing scuppers on main deck forward of deckhouse as required by 33 CFR 155.310 (a).
Condition: Unknown
Due 30 December 1992
Resolved 16 December 1992
Documentation
Issued 30 October 1992 Resolved
Provide transfer procedures as required by 33 CFR 155.750.
Condition: Unknown
Due 30 January 1993
Resolved 16 December 1992
Documentation
Issued 30 October 1992 Resolved
Obtain Safe Manning Certificate from flag state admnistration which reflects the decrease in manning as authorized by classification society.
Condition: Unknown
Due 30 January 1993
Resolved 16 December 1992
Deck/Cargo
Issued 3 August 1991 Resolved
Replace flame screens that are missing from all vent lines that require same prior to returning to U.S. waters.
Condition: Unknown
Due 3 August 1991
Resolved 3 August 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.