MAURY USCG vessel records Sign in
← All vessels

SMART I

SMART I is a 1981 freight ship. The Coast Guard has recorded 31 inspections since 1991, most recently in November 2008, along with 32 deficiencies — 1 with no resolution recorded — and 6 operational controls.

Records from 1991 to 2008. Most recent: inspection, 13 November 2008.

Built
1981
Last inspected
13 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8024519 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
365825
Flag
PANAMA
—
Maury page id
psix-365825

Inspections, by type

…with no type recorded20
Years with a record 12 calendar years (1991–2008)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39634 - Convention (Subpart B), Gross Ton
23817 - Convention (Subpart B), Net Ton
82650 - Displacement, Ton
64860 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

13 November 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3357521
18 September 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3321817
18 July 2008 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3264823
9 February 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3141495
8 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3144041
8 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3146129
10 December 2007 MARPOL Annex I Examination · Ballast Water Examination · Deficiency Check · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3106027
6 December 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3110672
28 November 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3105959
20 August 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2753605
14 August 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2748372
14 August 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2858034
12 August 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2745063
3 August 2006 ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2725696
2 August 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2739615
19 October 2004 ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2220399
7 June 2002 Ballast Water Examination · Deficiency Check · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1627983
10 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413770
12 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411846
9 January 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 411540
15 October 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 408745
15 July 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 393296
3 January 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 477881
28 October 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 371718
24 August 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 647336
23 August 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 369803
23 August 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 862901
30 December 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 535146
30 December 1993 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1362904
7 April 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 357376
31 July 1991 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 345329

Deficiency record · 32

Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 18 July 2008 Resolved
The PSCO found numerous cooling water leaks in the No. 3 generator. Vessel is prohibited from running the number 3 generator while in US waters until repairs are made.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 18 September 2008
Resolution: The #3 cylinder head for the #3 generator was removed, the water guide pipe was removed and the o-rings were renewed. The engine was reassembled, tested sat. with no water leaks.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 18 July 2008 Resolved
The PSCO found cracks in the double jacket fuel line protection covering of the #2, 3 and 4 cylinders on #2 generator, #3 and 5 cylinders on the # 3 generator, also 4 bolts were missing from each of the 5 fuel pumps on #3 generator. Make repairs and provide report.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 18 September 2008
Resolution: Permanent repairs were carried out on the #2 and #3 generator. Engines were tested sat as per China Class Society survey report.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 July 2008 Resolved
The PSCO found hydraulic leaks in the number 3 and 9 cargo hatch cover motors and hydraulic pressure unit in forecastle. Make repairs and provide class report.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 18 September 2008
Resolution: The hydraulic motors of No. 3 & No. 9 hatch covers were overhauled, tested and found sat as per China Class Society survey report.
Engineering › Steering Gear System › Valve, Control
Issued 18 July 2008 No resolution recorded
The PSCO found several leaks in the vessel's hydraulic steering system. Provide a classification society report attesting to the integrity of the hydraulic steering systems.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Compressed Air System (start air) › Valve
Issued 9 February 2008 Resolved
The Master Stated that the vessel experienced a power loss while the main engine ran at ahead-astern during anchoring. Main engine has a starting problem. The crew checked the Main engine starting air system and found that the starting control air distributor was out of order. The crew checked all the air distributor valves to clean, and replaced sliding valve for cylinder No. 1 with a new one.
Action required: 705 - Other - as specified
Due 9 February 2008
Resolved 9 February 2008
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 10 December 2007 Resolved
PSCO noted two soft patches on the Main Engine jacket water cooling piping. Repair to the satisfaction of the attending classification society surveyor.
Action required: 15 - Rectify deficiencies by next port
Due 15 December 2007
Resolved 4 February 2008
Resolution: Recieved class reoprt from China Classification Society satisfying requirement.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 10 December 2007 Resolved
PSCO noted that the vessel's echo depth sounder is still inoperable. The vessel is to submit a tech report attesting to the proper operation of the echo depth sounder. The vessel was given until 31JAN08 by Panama Maritime Authority to repair the echo depth sounder.
Action required: 705 - Other - as specified
Due 31 January 2008
Resolved 4 February 2008
Resolution: Recieved class report from China Classification Society satisfying requirement.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 3 August 2006 Resolved
Safety Equipment Certificate (Form E) states 60 persons on port side and 56 persons on starboard side. Both port and starboard lifeboats are labeled 40 persons. Class Society surveyor to attest to proper number of persons for both lifeboats. Cite: SOLAS 74A III/31
Action required: 705 - Other - as specified
Due 4 September 2006
Resolved 10 December 2007
Resolution: PSCO verified the correction made on the Safety Equipment Certificate satisfying the requirement.
Construction/Loadline › Structures › Door
Issued 19 October 2004 Resolved
Make all access openings, specifically doors, of the enclosed superstructure comply with regulation 12, chapter II of the I.L.L.C. where now many of the doors are not able to be closed weathertight and several door frames are not weathertight. Complete to the satisfaction of Class. I.L.L.C. 1966, Chp. II Reg. 12.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2006
Resolution: PSC exam conducted and discrepancy was resolved.
Electrical › Electrical Distribution System (service)
Issued 7 June 2002 Resolved
Numerous electrical distribution boxes, lighting fixtures, wires and meters throughout the vessel are open, disconnected, not properly secured, and in poor condition. Properly repair and secure all electrical equipment.
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 10 June 2002
Resolution: All repaired to satisfaction of class.
Fire Fighting › Fire Pumps
Issued 7 June 2002 Resolved
Emergency fire pump took 20 minutes to start because of weak starting batteries. Prove operation of the pump starting batteries.
Action required: 705 - Other - as specified
Due 14 June 2002
Resolved 8 June 2002
Resolution: Received class report stating starting cables repaired and operational test carried out with satisfactory results.
Engineering › Steering Gear System
Issued 7 June 2002 Resolved
Steering system servo cooling motor burnt out and smoking. Repair to the satisfaction of class prior to departing 12 mile anchorage LEGACY COMPONENT DESC: servo cooling fan motor
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 8 June 2002
Resolution: Received class report stating shaft of servo cooling motor replaced and operational test carried out with satisfactory results.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 June 2002 Resolved
Main engine #2 cylinder has excessive cooling water leak. LEGACY COMPONENT DESC: Cylinder
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 8 June 2002
Resolution: Received class report stating that the sealed ring of the cylinder head was replaced and tested with no leaks.
Engineering › Steering Gear System
Issued 7 June 2002 Resolved
Both steering pumps have noteworthy hydraulic oil leaks on the oil distribution blocks. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 8 June 2002
Resolution: Received class report stating that the sealed rings in both oil distribution blocks were replaced and tested with no leaks.
Engineering › Diesel Engine (propulsion-electric)
Issued 7 June 2002 Resolved
NO. 3 generator has wooden plug installed in scavenging air cooler. LEGACY COMPONENT DESC: Scavenging air cooling
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2002
Resolved 8 June 2002
Resolution: Plug removed and gauge line reconnected.
Engineering
Issued 7 June 2002 Resolved
All engine room and steering compartment machinery covered with oil and dirt. LEGACY COMPONENT DESC: engineering spaces
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2002
Resolved 8 June 2002
Resolution: Received class report stating that all engine room and steering compartment machinery was cleaned.
Engineering › Diesel Engine (auxiliary)
Issued 7 June 2002 Resolved
NO. 2 generator has two temporary patches on the jacket water cooling piping. Permanently repair to sat. of class LEGACY COMPONENT DESC: Jacket water piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 July 2002
Resolved 10 June 2002
Resolution: Piping renewed to satisfaction of class.
Documentation
Issued 12 January 1998 Resolved
VESSEL'S LOADLINES NOT PAINTED IN CONTRASTING COLORS._x001C_ _x001C_ ILLC 66 ANNEX I/8_x001C_ _x001C_
Condition: Unknown
Due 12 February 1998
Resolved 7 June 2002
Lifesaving
Issued 15 October 1997 Resolved
THE LIFEBOAT WINCHES BRAKES ARE INOPERABLE FOR BOTH PORT AND STBD LIFEBOATS. HAS TWO EXTRA LIFERAFTS ONBOARD UNTIL LIFEBOAT REPAIRS ARE MADE, THIS HAS BEEN APPROVED BY CLASS.
Condition: Unknown
Due 17 October 1997
Resolved 22 October 1997
Unknown
Issued 15 October 1997 Resolved
THE AUDIBLE ALARM FOR THE OILY WATER SEPERATOR WAS INOPERABLE.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Navigation
Issued 15 October 1997 Resolved
CHARTS 2563, 2564 AND 2603 MISSING CORRECTIONS.
Condition: Unknown
Due 17 October 1997
Resolved 22 October 1997
Navigation
Issued 15 July 1996 Resolved
SHIP'S 2ND RADAR IS INOPERATIVE. (33CFR 164.11(r)). CORRECT PRIOR TO DEPARTURE/19JUL96.
Condition: Unknown
Due 19 July 1996
Resolved 17 July 1996
Navigation
Issued 15 July 1996 Resolved
SHIP'S MANEUVERING INFORMATION IS NOT COMPLETE AND SPECIFIC ON BRIDGE. (33CFR 164.35(g)). CORRECT PRIOR TO NEXT U.S. PORT AFTER FOREIGN VOYAGE/15AUG96.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Accommodation/Occupational Safety
Issued 23 August 1994 Resolved
A VIOLATION OF 33 C.F.R. 159.7 IN THAT THE LABEL ON THE MARINE SANITATION DEVICE DID NOT CONTAIN THE REQUIRED INFORMATION.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Construction/Loadline
Issued 30 December 1993 Resolved
WEATHERTIGHT DOORS NOT COMPLETELY CLOSING. ADJUST DOGS FOR PROPER CLOSURE.
Condition: Unknown
Due 30 December 1993
Resolved 30 December 1993
Electrical
Issued 30 December 1993 Resolved
LIGHTS ON MAIN DECK, BOAT DECK AND ENGINE ROOM, EMERGENCY PUMP ROOM, REEFERSPACE MISSING GLOBES, COVERS AND/OR GUARDS. REPLACE ALL MISSING GLOBES, COVER AND GUARDS BY NEXT RETURN TO U.S. PORT. SOLAS_x001C_ _x001C_
Condition: Unknown
Due 30 December 1993
Resolved 30 December 1993
Electrical
Issued 30 December 1993 Resolved
MAIN DISTRIBUTION PANEL IN ENGINE CONTROL ROOM NO GUARD IN REAR TO PROTECT PERSONNEL FROM LIVE ELETRICAL PARTS. PLACE SUITABLE GUARD TO PREVENT ELECTIRCAL SHOCK. SOLAS CHAP. II-1, PT. D, REGULATION 45.2
Condition: Unknown
Due 30 December 1993
Resolved 30 December 1993
Lifesaving
Issued 30 December 1993 Resolved
ENGINE HATCH MISSING FROM STARBOARD LIFEBOAT. REPLACE ENGINE COVER. _x001C_ SOLAS, CHAP. III, PT. C, REGULATION 41.6.9. REPAIR BEFORE NEXT RETURN TRIPTO U. S. PORT.
Condition: Unknown
Due 30 December 1993
Resolved 30 December 1993
Accommodation/Occupational Safety
Issued 30 December 1993 Resolved
VESSEL'S HOSPITAL SHOWER AND ONE FAUCET INOP. REPAIR AND PROVE._x001C_ ILO-147
Condition: Unknown
Due 30 December 1993
Resolved 30 December 1993
Fire Fighting
Issued 30 December 1993 Resolved
SUICIDE NOZZLES WITH NO SHUTOFF AT NOZZLE IN SERVICE. REPLACE WITH DUAL PURPOSE TYPE NOZZLE. SOLAS, CHAP. II-2, PT. A, REGULATION 8.4.
Condition: Unknown
Due 30 December 1993
Resolved 30 December 1993
Accommodation/Occupational Safety
Issued 7 April 1993 Resolved
VESSEL'S MSD DID NOT HAVE A CERTIFICATION LABLE AFFIXED.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Documentation
Issued 7 April 1993 Resolved
VESSEL'S DOI NOT INITIALED BY CHIEF ENGINEER.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.