Records from 1999 to 2026. Most recent: inspection, 30 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
30 March 2026
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8333911
1 October 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8244981
26 September 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7997864
6 May 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7907574
26 July 2023
Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7742354
10 April 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7665863
29 September 2022
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7560324
31 May 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7447454
16 September 2021
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7303409
26 June 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6991208
23 June 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6984346
8 July 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6742085
30 August 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6520476
23 May 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6429399
25 September 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6264373
16 November 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6041625
13 October 2016
Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6030688
29 June 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5989420
3 June 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5899138
8 September 2015
Internal Structural Exam · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5233095
7 August 2014
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4946892
4 June 2014
Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4879283
2 June 2014
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4882773
14 June 2012
Internal Structural Exam · Drydock Exam · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4343794
8 September 2011
Re-Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4139212
20 September 2010
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3851281
14 April 2009
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3454742
10 September 2008
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3318489
5 September 2007
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3041139
7 May 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2925103
19 September 2006
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2777386
18 September 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2780935
1 August 2005
Re-Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2431155
14 April 2005
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2343989
7 April 2005
Type not recorded
No type recorded · Station Fort Myers Beach · USCG Southeast District (CGD-SE) · Activity 2414231
9 July 2004
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2126119
21 July 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1850306
7 April 2003
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1770382
21 March 2003
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1760650
26 July 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1650606
22 May 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1066059
20 April 2001
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1451691
31 July 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1437772
9 September 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1118624
2 July 1999
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1463487
28 April 1999
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1438865
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 October 2025
Resolved
Prior to operating beyond 3NM renew EPIRB battery and hydrostatic release.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 October 2025
Resolved 22 October 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2025
Resolved
Prove proper operation of aft bilge alarm.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2025
Resolved 22 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2025
Resolved
Renew life ring with approved type for route.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2025
Resolved 22 October 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2025
Resolved
Seize all rig shackles, turnbuckles and renew hardware securing boom gooseneck.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2025
Resolved 22 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 September 2022
Resolved
All vessels on a Limited Coastwise route must carry 6 red hand flares and 6 orange smoke signals. Flares onboard are expired.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2023
Resolved 28 June 2023
Resolution: New flares on board
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 September 2022
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel crew is not enrolled in a drug/alcohol program and does not have alcohol swabs onboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 26 July 2023
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 September 2022
Resolved
Each vessel that operates beyond three miles from the coastline must have an EPIRB installed to automatically float free and activate. Hydrostatic release for EPIRB is expired. Vessel is restricted to within 3 miles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 28 June 2023
Resolution: Hydrostatic release renewed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022
Resolved
A vsl must have at least three 2.5 gallon buckets with an attached lanyard and the words FIRE BUCKET stenciled
in contrasting color. Vessel fire buckets are too large.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 28 June 2023
Resolution: Proper fire buckets on board
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 29 September 2022
Resolved
At each initial and subsequent inspection for certification, a man overboard or fire drill may be required. Drills were not conducted during the inspection and will be conducted in the Spring when the vessel goes back into the water.
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 26 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 August 2019
Resolved
Type I Adult Life Jacket damaged. Provide enough Lifejackets for total person allowed on board. 1 Additional Life jacket needed.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2019
Resolved 23 June 2020
Resolution: Provided proof of satisfactory Type I PFD, all sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 August 2019
Resolved
Marine Radio Operators Permit (MROP) not on board. Provide Proof of MROP and maintain on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 23 June 2020
Resolution: Provided proof of valid Marine Radio Operator's Permit, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 August 2019
Resolved
Sound signal not on board. Provide proof of sound signal device and maintain on board.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2019
Resolved 23 June 2020
Resolution: Provided proof of satisfactory sound signal device onboard the vessel, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 August 2019
Resolved
Life jacket donning placards missing. Provide and mount in appropriate locations and provide number of lifejackets in each storage location.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2019
Resolved 23 June 2020
Resolution: Verified that appropriate life jacket donning instructions were posted in an appropriate location; and that life jacket storage areas were properly labeled with quantity of life jackets, all sat.
Sail Rigging › Deck Hardware › Shackles
Issued 25 September 2017
Resolved
Shackle is elongated on fwd roller furling attachment to bow.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 1 July 2018
Resolution: Replaced in kind with new component.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 25 September 2017
Resolved
Sail Rig Preventitave Manintence Procedures not completed for vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 1 July 2018
Resolution: Inspection log, and sail rig Preventative Maintenance Program implemented.
Communications › Radio Communications › EPIRB
Issued 25 September 2017
Resolved
Hydro release expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 1 July 2018
Resolution: New Hydrostatic release replaced with new to expire in 05 / 2020.
Sail Rigging › Spars › Boom and Gooseneck Fitting
Issued 3 June 2016
Resolved
Aft end of boom is fractured. Repair and provide pictures of re-welded section.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2016
Resolved 29 June 2016
Resolution: Fracture repaired.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 3 June 2016
Resolved
Vessel must conduct sea trials under full sail with cognizant USCG marine insdpector on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2016
Resolved 29 June 2016
Resolution: Conducted satisfactory sea trial under full sail plan.
Documentation › Certificates/Documents › Stability Letter
Issued 8 September 2015
Resolved
Stability Letter was not onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 10 September 2015
Resolution: USCG MSC failed to issue a letter. Owner operator was given a new copy of their stability letter for keeping onboard.
Sail Rigging › Chainplates › Fasteners
Issued 2 June 2014
Resolved
Stbd AMA chainplate for the shoud has loose bolts and one short bolt at lognitudinal frame. Also upper two bolts are working off endge of backing board. Port AMA chainplate has one short bolt at lognitudinal frame . Tighten all loose bolts, replace short bolts (on frame) and submit repair proposal for Stbd chain plate upper bolts, replacement/reinforcement.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 11 August 2014
Electrical › Electric Supply System (service) › Transformer
Issued 14 June 2012
Resolved
Installed power inverter and solar panels must remain secured at all times when passengers are on board, until approved plans are received from MSC and inspected by USCG marine inspector.
Action required: 705 - Other - as specified
Due 1 October 2012
Resolved 19 June 2014
Construction/Loadline › Structures › Superstructure
Issued 26 September 2011
Resolved
Prior to carrying passengers perform operational sail test of new rigging install.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2012
Construction/Loadline › Structures › Superstructure
Issued 26 September 2011
Resolved
Prior to carrying passengers complete USCG review of rigging installation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2012
Navigation › Piloting/Steering › Marine Charts
Issued 8 September 2011
Resolved
Provide current up to date charts or correct existing charts.
Action required: 705 - Other - as specified
Due 26 September 2011
Resolved 26 September 2011
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 September 2011
Resolved
Renew galley high level alarm buzzer.
Action required: 705 - Other - as specified
Due 26 September 2011
Resolved 26 September 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 September 2008
Resolved
Replace all waterlight batteries with lug type batteries. *required annually*
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 3 November 2008
Resolution: Rcvd package from [name withheld] showing receipt for waterlight batteries and photos of batteries installed in units.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 September 2008
Resolved
Outfit waterlights for lifefloats with 18' x 5/15" line.
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 3 November 2008
Resolution: Rcvd package from [name withheld] showing appropriate line installed on waterlight/lifefloat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 8 September 2008
Resolved
Replace pull cable for kidde fixed fire extinguisher for engine room.
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 3 November 2008
Resolution: Rcvd package from [name withheld] showing receipt for fixed fire extinguisher pull cable and picture of manual pull reinstalled.
Navigation › Piloting/Steering › Marine Charts
Issued 8 September 2008
Resolved
Provide current chart for all areas transitted per COI.
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 3 November 2008
Resolution: Rcvd package from [name withheld] showing receipt for charts.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 8 September 2008
Resolved
Provide 2 red signals and 3 orange day signals.
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 3 November 2008
Resolution: Rcvd package from [name withheld] showing receipt for signals.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 19 September 2006
Resolved
Properly mouse all shackles on rigging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 29 September 2006
Resolution: Mailed in pictures reflecting all shackles properly moused.
Engineering › Fuel Oil Service System › Filter
Issued 1 August 2005
Resolved
Properly repair fuel leak on secondary fuel filter NLT 01 SEP 05.
Due 1 September 2005
Resolved 1 September 2005
Resolution: Repaired
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 August 2005
Resolved
Properly repair bearing block on shaft.
Due 1 September 2005
Resolved 1 September 2005
Resolution: Repaired
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 1 August 2005
Resolved
Provide FCC operators permit.
Due 1 September 2005
Resolved 1 September 2005
Resolution: Provided certificate
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 August 2005
Resolved
Label high level bilge alarm.
Due 1 September 2005
Resolved 1 September 2005
Resolution: Labeled.
Deck/Cargo › Holds/Tanks › Hatch
Issued 1 August 2005
Resolved
Replace vent on weathertight hatch.
Due 1 September 2005
Resolved 1 September 2005
Resolution: Replaced
Engineering › Bilge Water Management System › Valve
Issued 14 April 2005
Resolved
Provide valves for bilge pump overboard discharge penetrations.
Action required: 705 - Other - as specified
Due 28 April 2005
Resolved 28 April 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 April 2005
Resolved
Provide cotter pins for all turnbuckles.
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 28 April 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 April 2005
Resolved
Complete annual inspection prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2005
Resolved 4 May 2005
Resolution: Annual inspection completed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 April 2005
Resolved
Provide rigging report.
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 28 April 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 July 2004
Resolved
Fixed Fire Fighting tank in Engine Room not weighed by certified official, nor owner monthly self-testing logged in logbook. Preform inspection on tank.
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 12 July 2004
Resolution: Tank removed from vessel and inspection preformed by FIREX, Inc.
Communications › Radio Communications › EPIRB
Issued 9 July 2004
Resolved
EPIRB battery replaced in 2004, but EPIRB Hydro Release expired. Replace Hydro Release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 12 July 2004
Documentation › Certificates/Documents › FCC SSL
Issued 9 July 2004
Resolved
FCC Safety Certificate is expired. Provide current FCC Safety Certificate. Due date extended to 20 JUL 04 due to scheduling conflicts with the FCC inspector.
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 7 April 2003
Resolved
Replace both Halyard Winch bases on Main Mast. Aluminum bases and fasteners are severely corroded.
Due 16 May 2003
Resolved 2 May 2003
Resolution: Cleared as worklist item. CG-835 issued in error. O/O installed new bases and hardware while still in yards.
Accommodation/Occupational Safety › Occupational Safety
Issued 21 March 2003
Resolved
Renew Main Halyard Winch Base and Hardware. Both wasted due to galvanic corrosion.
Due 7 May 2003
Resolved 2 May 2003
Communications › Radio Communications
Issued 26 July 2002
Resolved
EPIRB not on board due to being sent back to manufacturer for new battery installation. LEGACY COMPONENT DESC: EPIRB
Due 29 August 2002
Resolved 1 August 2002
Resolution: EPIRB re-installed on vessel
Accommodation/Occupational Safety
Issued 20 April 2001
Resolved
INSTALL LOCKING DEVICE ON WYE VALVE FOR SEWAGE OVERBOARD DISCHARGE.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Fire Fighting
Issued 20 April 2001
Resolved
CONDUCT ANNUAL SERVICING OF FIXED EXTINGUISHING SYSTEM, PROVIDE SERVICE REPORT SHOWING ENGINE AND EXHAUST BLOWER SHUTS DOWN AND THAT ALARM SOUNDS.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Lifesaving
Issued 20 April 2001
Resolved
INSTALL DETACHABLE CLIP ON RING BUOY LIGHT AND MOUNT LIGHT TO ALLOW IT TO FLOAT FREE.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Lifesaving
Issued 20 April 2001
Resolved
PROVIDE PROOF OF EPIRB REGISTRATION.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Documentation
Issued 20 April 2001
Resolved
PROVIDE DRUG TESTING PROGRAM TO INCLUDE EAP AND CREW TRAINING.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Electrical
Issued 20 April 2001
Resolved
PROPERLY MOUNT WATER PUMP IN CENTER HULL PORT SIDE MACHINERY SPACE.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Unknown
Issued 31 July 2000
Resolved
HAVE FIRE EXTINGUISHERS INSPECTED AND PROVIDE PROOF OF SAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 September 2000
Resolved 7 September 2000
Unknown
Issued 31 July 2000
Resolved
REPLACE FUEL SUPPLY LINE WITH USCG APPROVED TYPE AND DOUBLE CLAMP; REPLACE FUEL RETURN LINE WITH APPROVED TYPE MEETING ASME 1492J._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 September 2000
Resolved 7 September 2000