Inspection history · 32
22 August 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3035424
3 July 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3001464
25 October 2006
Deficiency Check · COI Inspection · Internal Structural Exam · Damage Survey · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2807424
20 September 2005
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2542524
14 August 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2471031
10 November 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2250660
18 September 2003
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1907634
6 December 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1715290
18 September 2001
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458936
9 February 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058660
3 February 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141723
3 February 2001
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1058607
25 August 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365957
5 April 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800747
7 September 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1471394
28 August 1998
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431994
24 October 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1113948
25 September 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1386100
17 September 1996
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463982
12 September 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390114
29 August 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396351
14 October 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177472
13 September 1994
Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414355
24 August 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405586
16 September 1993
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457121
14 August 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362830
9 March 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 834884
9 March 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1145311
8 September 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937598
1 September 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248319
24 October 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 936858
29 August 1991
Plan Review "T" Boat · Initial Certification · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252681
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 August 2007
Resolved
Renew Port Navigation Light prior to night time operations.
Due 22 September 2007
Resolved 4 September 2007
Resolution: Renewed light.
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 August 2007
Resolved
Install battery cover on engine room battery.
Due 22 September 2007
Resolved 4 September 2007
Resolution: Installed batery cover.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 August 2007
Resolved
Demonstrate proper operation of bilge alarms, due to not making continuous visual and audibel alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 September 2007
Resolution: Demonstrated proper operation of bilge alarms.
Lifesaving › Lifefloat › Markings
Issued 22 August 2007
Resolved
Re-Stencil life float with vessel name and capacity.
Due 22 September 2007
Resolved 4 September 2007
Resolution: Re-Stenciled life float properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 August 2007
Resolved
Install metallic clamps to hold wiring in engine room.
Due 22 September 2007
Resolved 4 September 2007
Resolution: Installed metallic clamps to support engine room wiring.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 October 2006
Resolved
Vessel has been operating since 18 September 2006 to present day with an expired Certificate of Inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 5 October 2007
Engineering › Fuel Oil Service System › Piping
Issued 25 October 2006
Resolved
Fuel piping at the fuel filter did not have the required cap at the end.
Due 17 December 2006
Resolved 28 November 2006
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 25 October 2006
Resolved
The diamond day shape was missing.
Due 17 December 2006
Resolved 28 November 2006
Stability › Weathertight Integrity › General
Issued 25 October 2006
Resolved
Weather stripping on the doors needed renewal.
Due 17 December 2006
Resolved 28 November 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2006
Resolved
All items in the first aid kit with expiration dates were expired.
Due 17 December 2006
Resolved 28 November 2006
Documentation › Logs/Records › Logbook (official)
Issued 25 October 2006
Resolved
No log book or lifesaving maintenance record books were onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 October 2006
Resolved
Emergency instuctions were not available.
Due 17 December 2006
Resolved 28 November 2006
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 25 October 2006
Resolved
EAP information was not available.
Due 17 December 2006
Resolved 28 November 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 October 2006
Resolved
Vessel crew was not keeping up with general housekeeping.
Due 17 December 2006
Resolved 28 November 2006
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 November 2004
Resolved
Swung compass same day.
Condition: Improper/Lack of Maintenance
Due 10 November 2004
Resolved 10 November 2004
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 November 2004
Resolved
Condition: Improper/Lack of Maintenance
Due 10 November 2004
Resolved 10 November 2004
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 November 2004
Resolved
Hydrostatic release not servicable.
Condition: Improper/Lack of Maintenance
Due 10 November 2004
Resolved 10 November 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 November 2004
Resolved
Condition: Improper/Lack of Maintenance
Due 10 November 2004
Resolved 10 November 2004
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 10 November 2004
Resolved
Missing cover.
Condition: Improper/Lack of Maintenance
Due 10 November 2004
Resolved 10 November 2004
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 10 November 2004
Resolved
Condition: Improper/Lack of Maintenance
Due 10 November 2004
Resolved 10 November 2004
Lifesaving › Buoyant Apparatus
Issued 18 September 2003
Resolved
Properly attach sea painter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Showed Master how to configure sea painter
Engineering › Fuel Oil Service System › Hose
Issued 12 December 2002
Resolved
Provide fuel hoses to meet 30" max requirement
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 18 December 2002
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 December 2002
Resolved
Provide retroreflective material for lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 18 December 2002
Construction/Loadline
Issued 3 February 2001
Resolved
VESSEL TO BE REMOVED FROM SERVICE AND PROCEED TO SHIPYARD FOR PROPER REPAIRS - NO PASSENGERS ALLOWED ONBOARD UNTIL USCG MARINE INSPECTOR APPROVES REPAIRS.
Condition: Unknown
Due 3 February 2001
Resolved 3 February 2001
Construction/Loadline
Issued 7 September 1999
Resolved
PROVE PROPER OPERATION OF HIGH BILGE ALARMS.
Condition: Unknown
Due 9 September 1999
Resolved 10 September 1999
Lifesaving
Issued 7 September 1999
Resolved
RESTENCIL LIFE BUOY WITH VESSEL NAME.
Condition: Unknown
Due 7 September 1999
Resolved 7 September 1999
Navigation
Issued 7 September 1999
Resolved
PROVE PROPER OPERATION OF HORN.
Condition: Unknown
Due 7 September 1999
Resolved 7 September 1999
Electrical
Issued 7 September 1999
Resolved
REMOVE WIRE NUTS FROM THROUGHTOUT VESSEL, BRIDGE, ENGINEROOM AND INTERNALLY.
Condition: Unknown
Due 7 September 1999
Resolved 7 September 1999
Engineering
Issued 7 September 1999
Resolved
REPLACE WIRE CLAMP ON EXHAUST IN RUDDER ROOM.
Condition: Unknown
Due 7 September 1999
Resolved 7 September 1999
Navigation
Issued 7 September 1999
Resolved
REPLACE OUTDATED PUBLICATIONS.
Condition: Unknown
Due 7 September 1999
Resolved 7 September 1999
Construction/Loadline
Issued 17 September 1996
Resolved
VESSEL SHALL BE MADE AVAILABLE FOR HULL EXAMINATION. VESSEL MUST BE HAULEDOUT TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 17 September 1996
Resolved 25 September 1996
Engineering
Issued 29 August 1995
Resolved
REPLACE ALL HOSE CLAMPED FUEL OIL LINES ON GENERATOR WITH USCG APPROVED LINES.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Electrical
Issued 29 August 1995
Resolved
INSTALL MISSING PANEL COVER INSIDE 120/240 VAC PANEL IN ENGINE ROOM. WIRING IS EXPOSED.
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Construction/Loadline
Issued 24 August 1994
Resolved
MAKE PENETRATIONS THROUGH ENGINE SPACE WATERTIGHT BULKHEAD WATERTIGHT IAW 46 CFR 171.114.
Condition: Unknown
Due 24 August 1994
Resolved 24 August 1994
Electrical
Issued 24 August 1994
Resolved
SEAL OPEN SPACE IN DISTRIBUTION BOX IN ENGINE SPACE.
Condition: Unknown
Due 24 August 1994
Resolved 24 August 1994
Accommodation/Occupational Safety
Issued 24 August 1994
Resolved
PROVIDE PERMANENT PLACARD STATING LOCATION OF LIFE JACKETS IAW 46 CFR 180.25-15(b).
Condition: Unknown
Due 24 August 1994
Resolved 24 August 1994
Accommodation/Occupational Safety
Issued 24 August 1994
Resolved
MARK EMERGENCY EXIT IAW 46 CFR 185.30-15.
Condition: Unknown
Due 24 August 1994
Resolved 24 August 1994
Documentation
Issued 1 September 1992
Resolved
PROVE VALID STICKER FOR CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 1 October 1992
Resolved 9 September 1992
Lifesaving
Issued 1 September 1992
Resolved
PROVIDE PROPER WATER LIGHT FOR LIFERING.
Condition: Unknown
Due 11 September 1992
Resolved 9 September 1992
Engineering
Issued 1 September 1992
Resolved
PROVE PROPER OPERATION OF MDE AHEAD AND ASTERN.
Condition: Unknown
Due 1 October 1992
Resolved 9 September 1992
Lifesaving
Issued 1 September 1992
Resolved
PROVIDE (3) COAST GUARD APPROVED LIFE JACKETS TO TOTAL 24.
Condition: Unknown
Due 1 October 1992
Resolved 9 September 1992
Documentation
Issued 1 September 1992
Resolved
PROVIDE PROOF OF STABILITY OR DOCUMENTATION SHOWING EVIDENCE OF THE TOTAL NUMBER OF PEOPLE CARRIED FOR DETERMINING SATISFACTORY STABILITY IN SERVICE OR CONDUCT A SATISFACTORY SIMPLIFIED STABILITY TEST IN THE PRESENCE OF A USCG MARINE INSPECTOR IN ACCORDINCE WITH 46 CFR 170.120(b) & 170.160(b).
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Documentation
Issued 29 August 1991
Resolved
PROVIDE ON BOARD A VALID FCC RADIO TELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991