Records from 2006 to 2026. Most recent: inspection, 23 July 2026.
Inspection history · 82
23 July 2026
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8445014
9 April 2026
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8345224
25 February 2026
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8307968
19 February 2026
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8312913
3 February 2026
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8305535
28 January 2026
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8302908
28 January 2026
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8367953
19 November 2025
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8271183
12 November 2025
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8270267
14 October 2025
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8251859
10 October 2025
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8250493
16 September 2025
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8235504
27 August 2025
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8220408
1 July 2025
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8172524
3 June 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8160381
29 May 2025
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8147344
25 May 2025
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8144706
23 March 2025
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8098636
25 February 2025
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8081268
4 December 2024
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8041816
30 November 2024
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8041414
31 October 2024
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8027633
14 October 2024
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8018648
11 September 2024
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8000023
31 July 2024
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7971229
6 June 2024
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8000731
9 March 2024
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7876646
4 March 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7873695
27 February 2024
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7868036
3 October 2023
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7795928
2 July 2023
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7728915
2 July 2023
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7828203
26 May 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7696927
25 May 2023
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7694598
25 May 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7696700
12 May 2023
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7687171
19 April 2023
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7672054
15 February 2023
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7637245
30 January 2023
COI Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7633091
16 November 2022
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7593998
20 October 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7580795
9 October 2022
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7574120
17 August 2022
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7534988
2 August 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7522742
5 July 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7496658
7 June 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7471134
31 May 2022
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7463804
2 March 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7405200
3 February 2022
Deficiency Check · In-Service Inspection · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7390488
2 January 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7374853
17 November 2021
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7352239
12 September 2021
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7311219
7 September 2021
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7306156
26 August 2021
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7296443
27 May 2021
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7207370
22 February 2021
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7144205
20 November 2020
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7103814
20 May 2020
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6925930
13 February 2020
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6888886
21 November 2019
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6836294
5 August 2019
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6773525
23 May 2019
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6656411
7 January 2019
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6606700
28 November 2018
MTSA Verification · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6566384
21 August 2018
MTSA Verification · Examination of Repairs · COI Inspection · Special · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6518387
25 May 2018
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6429019
21 February 2018
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358529
6 February 2018
In-Service Inspection · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6350116
6 February 2018
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6410276
27 January 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6347783
16 November 2017
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6280313
7 September 2017
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6261672
30 August 2017
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6255907
24 August 2017
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6206848
25 May 2017
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6125970
8 April 2017
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6121615
8 April 2017
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6121974
8 March 2017
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6033131
3 February 2017
Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6082474
15 September 2016
Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5954587
25 April 2016
Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5862038
16 March 2016
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5810245
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 February 2026
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. It was report the both shaft brakes on both A end and B end were not working. Conduct repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 January 2026
Resolved
A survey, either general or partial, shall be made every time an accident occurs or a defect is discovered, or whenever any important repairs or renewals are made.
Vessel operator reported loss of steering while switching from A end to B end. Conduct repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 September 2025
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness. CG was notified stating the vessel had a loss of steering while trying to leave Ferry Terminal Conduct repairs, test and conduct satisfactory sea trials to the satisfaction of USCG.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 March 2025
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter.
MI received notification that subject vessels No. 2 steering system was inoperable. Make in-kind repairs and make available to the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2025
Resolution: See tech report email for details. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 October 2024
Resolved
The aggregate capacity of the electric ship's service generating sources required in § 111.10-3 must be sufficient for the ship's service loads. Master reported insufficient service loads on #2 Generator during electrical transfer after routine EDG testing. Identify cause of the casualty, make effective repairs and prove proper operation of the electrical plant to the satisfaction of the CG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2024
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Trouble shoot and determine the cause of the "A" noise and make proper repairs to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2024
Resolved 27 March 2024
Resolution: MI witnessed satisfactory operation of rebuilt reduction gear on "B" end.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2024
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules. Vessel is experiencing a brake heating issue on B end main engine while B end is forward engine. Effect permanent repairs to the satisfaction of the attending Marine Inspector, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2024
Resolution: Shoreside maintenance adjusted caliper and conducted satisfactory sea trials.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 March 2024
Resolved
An inspection of the bridge-to-bridge radio stations on board vessels subject to the Vessel Bridge-to-Bridge Radiotelephone Act must be conducted by the same FCC-licensed technician. The vessel's FCC Bridge-to-Bridge and Safety Radiotelephony Certificates are expired. IAW 47CFR80.59
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2024
Resolved 31 July 2024
Resolution: Vessel received inspection and updated certificates. Added to documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 July 2023
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness.
The vessel captain notified the Coast Guard stating the "A" end main diesel engine secured its self due to loss of fuel oil pressure while mooring up at the Aurora Terminal.
Vessel is allowed a one time "deadhead" transit with zero passengers to the Bayside Terminal. Provide proof and findings to the duty Marine Inspector. Vessel is allowed to conduct sea trials with no passengers onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2023
Resolution: Maint' crew replaced the fuel pump on "A" end MDE. Tested all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 May 2023
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness.
The vessel captain notified the Coast Guard stating throttle control air box was leaking.
Provide proof and findings to the duty Marine Inspector. Vessel is allowed to conduct sea trials with no passengers onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2023
Resolution: NCDOT re-groomed throttle air box and crew conducted sea trials. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 May 2023
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. The crew self reported finding four fractures of welds in the water tank (A) end compartment in the overhead on the underside of the vehicle deck, during routine checks. Company Representative reported they took the vessel out of service and they intend to order marine chemist and coordinate welders for repairs. Provide repair plan to the Coast Guard for review and carry out approved repairs to the satisfaction of the Coast Guard prior to carriage of passengers or cargo.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2023
Resolved 15 May 2023
Resolution: Accepted objective evidence from company that satisfied the requirement. The fracture welds were repaired in-kind.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 April 2023
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation shall be IAW subchapter "F" of this chapter. Vessel reported an exhuast leak on the emergency gen. NCDOT must replace flex pipe with in-kind equipment and provide proof of repairs to attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2023
Resolution: MI received evidence that flex pipe was replaced anlong with attestation from the [name withheld] documents for additional info.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 February 2023
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Crew reported that during a layover dockside in Aurora Terminal, while running a boat drill it was noted the rescue boat went into limp mode. Troubleshoot the cause and report the cause to Coast Guard. Prove proper operation to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2023
Resolved 15 February 2023
Resolution: The rescue boat engine was changed out (In-kind), operationally tested satisfactory, and was accompanied by a master’s attestation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 November 2022
Resolved
One of the bilge pumps if the emergency power source is its source of power to meet part 56 of this chapter. Emergency bilge pump will start but not take suction while on emergency power. Provide proof to attending MI that emergency bilge pump is taking suction. 46 CFR 112.15-5(d) 46 CFR 56.50-55
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 November 2022
Resolution: Master claimed NCDOT tech tightened valve packing and was able to achieve suction and discharge. Vsl provided video evidence and master attestation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2022
Resolved
The aggregate capacity of the electric ship's service generating source must be sufficient for the ship's service loads. Vsl self reported that both SSDG and EDG could not maintain constant amperage causing fluctuations in electrical services. Vsl must provide generating sources which provide sufficient electrical service for the ship's service load.
Vsl is authorized a one time deadhead transit from Aurora, NC to Bayview, NC for repairs. 46 CFR 111.10-4
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2022
Resolution: Master submitted a statement attesting to the repair of the generators and switchboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 October 2022
Resolved
A survey either general or partial according to the circumstances shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficiency. The master reported that during morning boat checks the "B" end throttle control head was discovered to be leaking air. Trouble shoot, replace the defective equipment, and operational test to the satisfaction of the Coast Guard, prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2022
Resolved 9 October 2022
Resolution: The B end throttle control was replaced in kind with new control station and was satisfactory operational tested.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 August 2022
Resolved
Each life jacket must be marked with type-1 retro-reflective material approved under 46CFR164.018. The arrangement of the retro-reflective material must meet IMO resolution A.658(16). The retro-reflective tape on 18 adult sized life jackets were found wasted. Vessel restricted to 292 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 8 September 2022
Resolution: 21 adult sized life jackets renewed and placed in service.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 August 2022
Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. Ground was detected on the main switchboard while the generator was online with load.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 29 August 2022
Resolution: Electrician tracked ground to a soda machine in the passenger lounge. NCDOT tagged out soda machine and will have the unit removed at the next DD availability.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 August 2022
Resolved
Simultaneously with the operation of the transfer means under § 112.20-5, the diesel engine or gas turbine driving the final emergency power source must start automatically with no load on the final emergency power source. During morning daily checks the emergency generator failed to start. Determine cause of the casualty, make effective repairs and prove proper operation to the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 August 2022
Resolution: Fuel system on the engine was primed and started after switching the fuel filter. Ran EDG for 20 minutes under load; all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 July 2022
Resolved
Operating generators must provide continuous and uninterrupted source of power for the ship's service load under normal operational conditions. Master reported high jacket water temperature alarm on #2 generator due to possible faulty sensor. Provide cause of casualty, make effective repairs and prove proper operation to the attending Marine Inspector. If the #2 generator is needed for normal use, constant rounds of the equipment are required with additional monitoring measures.
Action required: 705 - Other - as specified
Resolved 6 July 2022
Resolution: 705- 07 days. Rcvd tech report from electrician. Broken wire identified on connector. New connector installed and tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 June 2022
Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see Subpart 70.35 of this chapter, will be considered satisfactory evidence of the structural efficiency of the vessel. The maintenance supervisor, reported it was discovered the vessel had structural damage to internal framing on board. Company must carry out temporary welding repairs to the two fractured transverse frames in "A" end steering compartment per submitted repair plan.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2023
Resolved 7 November 2023
Resolution: Frams repiar during vessel drydock period. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 June 2022
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting or other equipment. The maintenance supervisor, reported it was discovered the vessel has structural damage to internal framing on board. This damage was reportedly identified on three different framed areas in the vicinity of the "A' end steering compartment. The vessel is prohibited from movement until an attending Coast Guard inspector carries out an internal structural examination to their satisfaction and an approved repair plan is provided to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 7 June 2022
Resolved 8 June 2022
Resolution: Completed Internal Structural Examination and accepted repair plan to the satisfaction of the OCMI.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 3 March 2022
Resolved
Emergency generator must have audible alarm that sounds on high cooling water temp. Alarm did not sound during test. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2022
Resolved 16 March 2022
Resolution: Witnessed proper test of the J/W high temp alarm.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 March 2022
Resolved
Automation of vital systems or equipment must be provided on passenger vessels of 100 gross tons. Prove proper operation on reduction gear pressure test IAW PSTP 3.0.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 March 2022
Resolved 16 March 2022
Resolution: Witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2022
Resolved
A self priming, power driven fire pump must be installed on each vessel: (iii) Of more than 19.8 meters (65 feet) in length. Vessel notified OCMI office stating fire pump was not operational. Make repairs as needed and provide proof to attending inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2022
Resolution: Vessel found blown fuse associated with fire pump. Electrician replaced fused and crew test ran equipment. All SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 February 2022
Resolved
Vessel is required to carry radio equipment to comply with the requirements are specified in 47 CFR part 80. Integrate VHF radio with GPS and conduct marine radio check IAW USCG MSIB 20-20.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 3 March 2022
Resolution: VHF is integrated with GPS, MMSI is now in VHF. Radio check conducted; all sat
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 February 2022
Resolved
Design verification and periodic test procedure documents approved by the Coast Guard must be retained aboard the the vessel. Approved documents were not onboard during COI inspection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 3 March 2022
Resolution: Approved PSTP is now onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 February 2022
Resolved
Each vessel must carry a lifejacket for each person onboard and in addition at least 10% of child sized life jackets. MI discovered 46 adult sized life jackets and 01 child sized life jackets unserviceable. Vessel is restricted to 259 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2022
Resolved 3 March 2022
Resolution: New life jackets are now onboard and properly stowed. Vessel can operated with full compliment passengers IAW issued COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 January 2022
Resolved
A survey either general or partial shall be made every time a defect is discovered which affects the safety or efficacy. Master reported on of the three bearings had been found outside the housing. Determine cause and make proper repairs to the satisfaction of the Coast Guard on the A end rudder.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2022
Resolved 3 January 2022
Resolution: Company provided objective evidence, including video of the proper operation, changed out the rudder angle indicator box, and performed an electrical groom of the system which verified the operation on the A end rudder system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2021
Resolved
Classification: 02 CO2 fire extinguishers IVO of the port and starboard emergency access not properly labeled with classification.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 7 December 2021
Resolution: CO2 extinguishers were replaced with properly classifications.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2021
Resolved
A survey either general or partial, according to the circumstances shall be made every time an accident occurs or a defect is discovered which affects the safety or the vessel. The master reported an air leak near the regulator for the shaft brake. Troubleshoot to determine cause of casualty and repair to the satisfaction of the Coast Guard.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2021
Resolved 13 September 2021
Resolution: A fitting was replaced, system tested, and vessel operationally tested satisfactory to the Coast Guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 September 2021
Resolved
Vessels crew discovered the #2 SSDG would not secure during morning engineering checks. Vessel needs to further investigate and conduct repairs and ensure full operational test are satisfactory as per manufactures specs.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2021
Resolved 7 September 2021
Resolution: Company electrician discovered a faulty electronic speed switch. Crew conducted operational test; all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2021
Resolved
Employers must ensure that they and their crewmembers meet the requirements of 46 CFR 16. Crewmembers are unsure who the designated employee representative is and has not received drug awareness training. Company's policy or policy statement were not onboard.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 27 August 2021
Resolution: Company ensured all employees were trained and aware of the location of EAP information and policy.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 August 2021
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. During man overboard drill it was identified that the rescue boat engine throttle was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2021
Resolved 26 August 2021
Resolution: NCDOT replaced with new engine in kind. Operational test was all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 May 2021
Resolved
Cargo nets hooks missing 3 pins on A and B ends.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 May 2021
Resolution: Missings pins were added.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2021
Resolved
Fire extinguisher mount #9 was loose.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 May 2021
Resolution: mount was properly secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2021
Resolved
Drink machine bracket missing bolt and loose. Properly secure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 May 2021
Resolution: Drink machine is properly secured.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 May 2021
Resolved
Rescue boat fire extinguisher wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 28 June 2021
Resolution: Renewed fire extinguisher and properly installed
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 May 2020
Resolved
Recues boat davit controls getting stuck in the closed position when swing vsl overboard. The master must manual disengage controls locally at davit.
Action required: 705 - Other - as specified
Due 26 May 2020
Resolved 27 May 2020
Resolution: Vsl rep provided statement and video of davit controls operating without issue.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2020
Resolved
#12 fire ext. discharge hose cracking, replace with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2020
Resolution: Hose repalced
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 May 2020
Resolved
"Crews" first aid kid meds expired.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2020
Resolution: All kits were properly outfitted, this was a crews kits meds were removed from vsl.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 13 February 2020
Resolved
Prove 50% of crew CPR first aid. 7 crewman checked for CPR first aid card and only one was vaild.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2020
Resolution: Provided CPR training roster for 2 crews.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 February 2020
Resolved
CO2 bottle hose for e-gen loose.
Action required: 10 - Deficiency Rectified
Resolved 13 February 2020
Resolution: Hose was tighened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 February 2020
Resolved
A and B end shafts need to be adjuested to proper drips per min as per manufactures spec.
Action required: 10 - Deficiency Rectified
Resolved 13 February 2020
Resolution: Packing gland adjusted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 February 2020
Resolved
Deck hatchs were leaking on A and B end of LAZ.
Action required: 10 - Deficiency Rectified
Resolved 13 February 2020
Resolution: Hatches adjusted.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 January 2019
Resolved
Renew wasted lashings IWO all liferafts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 14 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 January 2019
Resolved
Renew rubber latch IWO 01 deck life jacket stowage box.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 14 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 January 2019
Resolved
Lubricate EDG door (very hard to operate)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 14 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 November 2018
Resolved
Rescue boat lifting shackles wasted, replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2018
Resolved 6 December 2018
Resolution: Photos and video provided by NCDOT contesting to the testing and replacement of the new hoisting bridle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 November 2018
Resolved
A-END R/W PVC piping union leaking in shaft alley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2018
Resolved 28 November 2018
Resolution: Removed union "loose" cleaned face and all SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 November 2018
Resolved
Painter line grommet missing for liferaft casing.
Action required: 705 - Other - as specified
Due 27 December 2018
Resolved 27 December 2018
Resolution: Received and accepted supporting documentation from company.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 November 2018
Resolved
B-end lifejacket markings missing or damaged.
Action required: 705 - Other - as specified
Due 27 December 2018
Resolved 27 December 2018
Resolution: Received and accepted supporting documentation from company.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 7 February 2018
Resolved
Identified 3" hole caused by wastage in sewage supply line to MSD. Make permanent repairs to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 21 August 2018
Resolution: Pipe has been properly repaired.
Electrical › Electric Generation Source (service) › Panelboard
Issued 6 February 2018
Resolved
Vessel experienced temporary blackout and subsequently left alarm panel illuminated post casualty.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2018
Resolved 7 February 2018
Resolution: Verified repairs and tested SSDG#1 satisfactory. Tested alarm panel #1 and alarm Panel #2 satisfactory.
Fire Fighting › Fire Main › Condition
Issued 7 September 2017
Resolved
Vessel reported (2) pin hole leaks in fire main.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2017
Resolved 28 September 2017
Resolution: Attended vessel conducted satisfactory operational test of fire main system. Cleared by attending M/I
Fire Fighting › Fire Main › Condition
Issued 8 April 2017
Resolved
Pin hole leak in fire main.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2017
Resolved 14 April 2017
Resolution: DD-Nags Head inspector cleared deficiency.
Fire Fighting › Fire Main › Condition
Issued 8 April 2017
Resolved
Pin-hole leak in fire main found directly above main engine (B-end).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2017
Resolution: Received photos of permanent weld repairs and proof of hydrostatic test.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve, Check (air start)
Issued 8 March 2017
Resolved
Electric Starter not engaging on A End of vessel, A Main will not start.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2017
Resolved 8 March 2017
Resolution: Replaced starter with new, all SAT.