MAURY USCG vessel records Sign in
← All vessels

IRON B

IRON B is a 1981 freight ship. The Coast Guard has recorded 13 inspections since 1991, most recently in July 2002, along with 11 deficiencies and 4 operational controls.

Records from 1991 to 2002. Most recent: inspection, 10 July 2002.

Built
1981
Last inspected
10 July 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7906942 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
366569
Flag
HONG KONG
—
Maury page id
psix-366569

Inspections, by type

…with no type recorded9
Years with a record 4 calendar years (1991–2002)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16443 - Regulatory (Subpart C or D), Gross Ton
6547 - Regulatory (Subpart C or D), Net Ton
21880 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

10 July 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1646288
5 July 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1642080
5 March 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1492321
4 March 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1491005
1 March 2002 In-Service Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1490506
1 March 2002 Deficiency Check · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1490510
11 February 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1485185
30 September 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 420885
19 June 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 417735
16 June 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 416617
21 January 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 348217
29 August 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 673956
24 July 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 472149

Deficiency record · 11

Navigation › Collision/Grounding Avoidance
Issued 1 March 2002 Resolved
Secondary Marine Radar inoperable, 33 CFR 164.37 (a). Spare parts required for repairs will be availible at vessels NPOC in Mobile, vessel was granted an inbound/outbound deviation from the Port of Houston. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Due 2 March 2002
Resolved 10 July 2002
Resolution: Received Technician report from [name withheld] attesting to the proper replacement of the secondary marine radar.
Lifesaving › Inflatable Liferafts
Issued 11 February 2002 Resolved
6-Man Liferaft missing, removed for servicing. Provide service report to local USCG.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 March 2002
Resolution: Verified lafe raft now on board.
Construction/Loadline › Structures
Issued 11 February 2002 Resolved
Fracture in hatchcombing of #3 hold, portside-aft corner near deck. (Has not cracked the deck).
Action required: 15 - Rectify deficiencies by next port
Resolved 1 March 2002
Resolution: Witnesses satisfactory repair to fracture in hatchcombing.
Construction/Loadline › Hull
Issued 11 February 2002 Resolved
Multiple fractures in framing at bottom of bulkwarks, port and starboard sides, amidships area.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 March 2002
Resolution: Witnessed satisfactory repair IWO framing at bottom of bulwarks in midship area.
Accommodation/Occupational Safety › Occupational Safety
Issued 11 February 2002 Resolved
Unable to conduct drills due to nature of cargo operations - shifting berths frequently.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 March 2002
Resolution: Verified drills conducted satisfactorily.
Fire Fighting
Issued 16 June 1998 Resolved
MISSING FIREPUMP GAUGE ON #2 FIREPUMP. SOLAS 74 II-2/4.3.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Engineering
Issued 16 June 1998 Resolved
REPAIR LEAKS TO BOILER RETURNS TO WATER TANKS. SOLAS 74 I.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Lifesaving
Issued 16 June 1998 Resolved
ACCESSIVE OIL ON BULKHEADS, OVERHEADS, AND LAGGING IN THE ENGINEROOM, PORTSIDE BY MAIN ENGINE. SOLAS 94 II/2.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Navigation
Issued 16 June 1998 Resolved
CONDUCT AND LOG EMERGENCY STEERING DRILL WITHIN 48 HOURS OF ENTRY TO NEXT U.S. PORT. 33CFR164.30 (d).
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Navigation
Issued 16 June 1998 Resolved
PROVIDE EQUIPMENT FOR PLOTTING RELATIVE MOTION PRIOR TO NEXT U.S. PORT. 33CFR164.35 (j).
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Navigation
Issued 16 June 1998 Resolved
CONDUCT AND LOG TEST OF EMERGENCY GENERATOR DURING PREARRIVAL TESTS PRIOR TO NEXT U.S. PORT. 33CFR164.30 (3).
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.