Documentation record
Registered dimensions (L × B × D)120.4 ft × 24.0 ft × 11.4 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)120.4 ft × 24.0 ft × 11.4 ft
ITC tonnagegross 219 / net 65
BuilderCREWBOATS INC · LOREAUVILLE, LA, UNITED STATES · built 1991
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 25 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it219 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
65 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
2 July 2026
Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 8431694
31 October 2025
Examination of Repairs · Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8261368
13 November 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8033854
31 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7818281
16 October 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7808153
25 January 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7626090
26 October 2021
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7339034
19 October 2021
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7335390
13 January 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7124029
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110453
30 October 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6844661
18 October 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6837431
28 March 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6651013
28 December 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6603652
2 November 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6299849
30 October 2017
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6297347
18 October 2016
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6024317
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 October 2025
Resolved
At each inspection operator shall be prepared to have vessels fuel and piping system ready for inspection. Fuel transfer pump leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2025
Resolved 7 November 2025
Resolution: Packing replaced. verified no leaks
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 November 2024
Resolved
Exposed hazards, such as gears and rotating machinery, must be properly protected by a cover, guard or rail. Neither generator has a cover over the exposed crankshaft pulley. 46 CFR 177.35-15 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2024
Resolved 20 November 2024
Resolution: Recieved proof of installed covers on both generators.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 November 2024
Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured prior to getting underway. MI's witnessed engine and steering gear room escape hatches leak water during rain squall. 46 CFR 185.20-15 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2024
Resolved 20 November 2024
Resolution: Recieved proof of new gaskets installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 January 2023
Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing device operable from both sides of the door. Engine room watertight door has inoperable closing device.m – 46CFR 179.330(b)
Action required: 10 - Deficiency Rectified
Due 25 January 2023
Resolved 26 January 2023
Resolution: Sufficient documentation was provided showing that the watertight closing device was made operable to the satisfaction of the lead Coast Guard Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 January 2023
Resolved
Irrespective of build date vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with part 186.450 that is installed in all enclosed areas where passengers and crew have routine access, including accommodation and machinery spaces. Vessel currently has modular detectors and will require an interconnected system as described. – 46 CFR 405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2023
Resolved 20 February 2023
Resolution: Added detectors and tied into existing panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 January 2023
Resolved
Each ring buoy must be marked with type II retroreflective material. Starboard lifebuoy needs renewed retro.– 46 CFR 405(c)
Action required: 10 - Deficiency Rectified
Due 24 February 2023
Resolved 26 January 2023
Resolution: Lifebuoy retro was replaced to the satisfactiion of the lead U.S. Coast Guard Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 October 2019
Resolved
A vessel on an oceans route is required to carry six hand red flare distress signals approved IAW 160.021 and six orange smoke distress signals approved IAW 160.037. Vessel only has 3 of each type of signal.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 November 2019
Resolved 1 November 2019
Resolution: Recieved photographic evidence of 6 new distress signals and receipt from marine supply company.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019
Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard. Nonconductive mat not provided.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 1 November 2019
Resolution: Recieved photographic evidence of conductive matting placed in front of switchboard and receipt to a marine rubber/gasket company.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 October 2019
Resolved
The floating waterlight approved under approval series 161.010 or other standard specified by the CMDT. must have a lanyard that is 5.5m (18ft) in length.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 1 November 2019
Resolution: Received photographic evidence new lanyards (bundled) attached to the floating waterlights.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 October 2019
Resolved
Each battery used in an item of lifesaving equipment except inflatable survival craft equipment, must be replaced during annual if expiration has passed. Waterlight batteries expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 1 November 2019
Resolution: Received photographic evidence of new battery purchase (7) and receipt from marine supply company.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 October 2019
Resolved
Spaces listed in 46CFR181.405 must be equipped with a fire detection and alarm system of an approved type IAW 46CFR part 76. Fire detection panel does not work.
Condition: Improper/Lack of Maintenance
Due 30 November 2019
Resolved 1 November 2019
Resolution: Received photographic evidence of illumination of the proper indicator light on the fire detection panel and the service technician's report.
Communications › Radio Communications › Emergency Source of Power
Issued 18 October 2016
Resolved
Prove operation of emergency power to required bridge equipment to satisfaction of attending marine inspector.IAW 46CFR183.310 Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2016
Resolution: Witnessed test of VHF, SSB, Nav lights, and public address system on e-power; all sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 October 2016
Resolved
Prove operation of bilge alarm system IAW 46CFR182.530 Prior to sail
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2016
Resolution: Witnessed test of all bilge alarm sensors, both audible and visual; all sat.
Communications › Public Address System › Broadcast Location
Issued 18 October 2016
Resolved
Prove operation of public address system to passenger accommodation space. IAW 46CFR184.115(b) Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2016
Resolution: Witnessed test of public address system to passenger accommodation space; all sat.
Fire Fighting › Portable Foam Applicators › General
Issued 18 October 2016
Resolved
Prove operation of fire fighting in-line eductor IAW 49CFR176.315 Prior to carriage of portable tanks.IAW 49CFR176.315
Action required: 705 - Other - as specified
Resolved 18 October 2016
Resolution: Vessel made in-line eductor serviceable, tested sat.
Engineering › Pressure Vessel › Pressure Gauge
Issued 18 October 2016
Resolved
Provide correct sized pressure gauges for air receivers. IAW 46CFR54.15-10 by 31OCT16.
Due 31 October 2016
Resolved 19 October 2016
Resolution: Verified re-newed pressure gauge installed; all sat.
Communications › Alarms/Indicators › Fire Alarm
Issued 18 October 2016
Resolved
Provide proof of operation or service to fire detection system and alarm system IAW 46CFR181.120 by 31OCT2016.
Due 31 October 2016
Resolved 19 October 2016
Resolution: Verified 3rd party documentation of service and testing to installed fire detection system; all sat.