DESERT PRINCESS

Built
1991
Last inspected
4 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

366756
Flag
UNITED STATES
Maury page id
psix-366756

Documentation record

Registered dimensions (L × B × D)74.2 ft × 28.0 ft × 6.0 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)74.2 ft × 28.0 ft × 6.0 ft
ITC tonnagegross 249 / net 74
BuilderMID-CITY STEEL FAB · LA CROSSE, WI, UNITED STATES · built 1991
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOULDER CITY, NV
Endorsements, as the file codes themcw_un
DocumentationValid · issued 26 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Net Ton
74 - Convention (Subpart B), Net Ton
81 - Regulatory (Subpart C or D), Gross Ton
249 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 65 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

4 January 2026 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284510
11 September 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8179703
9 January 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8056717
21 May 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7916780
19 January 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7856448
11 July 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7740031
22 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7657640
12 October 2022 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7578886
10 March 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7409731
14 January 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7119317
17 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6998758
2 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6826838
25 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6630435
30 April 2018 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6400662
8 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6397915
27 October 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6299144
29 September 2017 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6278164
18 April 2017 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6128194
18 April 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6128937
12 October 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6036855
6 June 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5899519
11 February 2016 DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813925

Deficiency record · 65

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 January 2026 Resolved
Vessels over 65ft must carry life ring buoys that meet 46CFR160.050. Grab line broken on ring buoy located top deck and second deck aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 January 2026
Resolution: Received objective evidence attesting to replacement of life ring buoy.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 January 2026 Resolved
All vessels 5nt must have a COD. COD expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 January 2026
Resolution: Received objective evidence attesting to vessel having a COD
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 4 January 2026 Resolved
Exhaust systems should have insulation to prevent injuries to crew. Exhaust lagging missing on port main diesel engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 January 2026
Resolution: Received objective evidence attesting to replacement of lagging
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 January 2026 Resolved
A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17. NFPA 17 requires the replacement of the fusible links annually if exposed to grease. NFPA 17 A.11.3.2. provide documentation from third party servicing company on inspection standards used for inspection or replace fusible links.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 January 2026
Resolution: Received objective evidence attesting to servicing of fire suppresion and replacement of fusible links
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 4 January 2026 Resolved
MSD vent on stbd side is damaged. Replace MSD vent valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 January 2026
Resolution: Received objective evidence attesting to repair of the stbd side MSD vent.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 January 2024 Resolved
Vessel has only 04 red flares. Provide the ship with 06 total flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2024
Resolution: Received pictures of the additional flares.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 January 2024 Resolved
Vessel's starboard navigation light was inopperable. Repair/replace the starboard nav light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2024
Resolved 29 January 2024
Resolution: Received pictures of the operational nav light and new bulb.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 March 2023 Resolved
2 main engine and 2 generator engines were found with ratchet straps supporting the exhaust mufflers. Provide each exhaust muffler with sturdy / permanent support brackets. Rectify within 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2023
Resolved 26 May 2023
Resolution: Received photographs of each engine/gen with permanent chains in place supporting the exhaust.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2023 Resolved
2 dead-ended electrical cables were found in void #2, ensure cables are electrically isolated and remove or provide each cable with a junction box to terminate. Rectify within 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2023
Resolved 9 June 2023
Resolution: Received photos of junction boxes installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2023 Resolved
Both generators have been replaced with new in recent years. Over current protection (breakers) appear to be original with 600 amp trip settings and new generator are rated for 300 amps. Provide adequately sized over current protection (no more than 115% of generator rating) for each generator. Rectify within 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2023
Resolved 26 May 2023
Resolution: Received photographs and technician report stating the breakers had been resized.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 March 2022 Resolved
Onboard COD not current.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 27 April 2022
Resolution: Corrected. Verified COD with expiry date of 14APR2023.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 March 2022 Resolved
Annual Fire fighting system servicing not available or onboard for inspection.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 19 January 2024
Resolution: Fire servicing paperwork provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 January 2021 Resolved
Install properly sized spanner wrenches at each fire station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received receipt and master's statement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 January 2021 Resolved
Replace batteries for floating lights for life rings x3.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received receipt and master's statement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2021 Resolved
Install metal garbage cans in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received receipt and master's statement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2021 Resolved
Clean galley exhaust ducting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received receipt and master's statement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2021 Resolved
Remove power-strips installed around vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received master's statement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2021 Resolved
Place Stern light cable splice inside J-box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received receipt and master's statement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2021 Resolved
Label all loads on electrical distribution panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received receipt and master's statement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 January 2021 Resolved
Install missing chains/wires on external void hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received picture and master's statement.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 January 2021 Resolved
Ensure all bilge alarms are secured to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received picture and master's statement.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 January 2021 Resolved
Replace lights in fwd gen space and gray water space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received receipt and master's statement.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 January 2021 Resolved
Repair/replace light switch in rudder room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received picture and master's statement.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 January 2021 Resolved
Secure reefers/griddles/coffee pots to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 12 February 2021
Resolution: Received pictures and master's statement. Fridge was not used and removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 January 2021 Resolved
Service bilge piping check valve in void 4.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 25 February 2021
Resolution: Recieved statement and picture of new check valve at manifold.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2020 Resolved
Vessel's direct current electrical system was faulty, resulting in the failure of: generators, steering, bilge pump, fire pump, bilge alarms, and navigational equipment. Prove proper operation of al vital systems.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2020
Resolution: Vessel's master provided a statement attesting to the full operation of all vital systems.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2020 Resolved
Replace all wasted grabs lines on life rings.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 June 2020
Resolution: Vessel renewed 03 life rings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 June 2020 Resolved
Provide annual servicing report for all fire extinguishers and installed system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 18 June 2020
Resolution: Vessel rep provided servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 June 2020 Resolved
Replace unauthorized fuel return hose on the port main engine with approved type hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 16 July 2020
Resolution: Vessel rep provided photos of replaced fuel hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2020 Resolved
Properly segregate adult and children's life jackets in aft stowage locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 16 July 2020
Resolution: Vessel rep provided photos of properly stowed life jackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 June 2020 Resolved
Seal bulkhead penetration in engine room forward bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 16 July 2020
Resolution: Vessel rep provided photos of sealed bulkhead penetration.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 June 2020 Resolved
Properly label emergency exits from engine room escapes hatches. Label outside of hatches with emergency escape to not block.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 16 July 2020
Resolution: Vessel rep provided photos of labeled emergency escapes.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 June 2020 Resolved
Repair small leak in fuel piping above starboard fuel tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 16 July 2020
Resolution: Vessel rep provided photos of renewed and painted piping.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 June 2020 Resolved
Re-install structural fire protection in-way-of engine room and generator room soft patches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 16 July 2020
Resolution: Vessel rep provided photos of restored structural fire protection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 October 2019 Resolved
Vessels enrolled in the AHE program are required to perform an annual hull assessment and random hull gaugings and provide objective evidence to the OCMI of the hull's condition. Vessel did not complete a hull assessment in 2018 and has not submitted a plan for a hull assessment in 2019. Vessel must submit a hull condition assessment plan to the OCMI and upon its approval, conduct a hull condition assessment and random hull gaugings as required by the OCMI.
Action required: 705 - Other - as specified
Due 27 October 2019
Resolved 23 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 February 2019 Resolved
Replace expired hand flares.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 26 February 2019
Resolution: Receipt and pictures received for review.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 February 2019 Resolved
Mount bilge alarm float in E/R.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 4 March 2019
Resolution: Received pictures of mounted alarm switch.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2019 Resolved
Remove or properly finish dead-end wires in void 3.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 4 March 2019
Resolution: Picture received.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2019 Resolved
Cover control box in void 3.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 4 March 2019
Resolution: Picture received.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2019 Resolved
Move battery wires from between engines out of bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 5 March 2019
Resolution: Pictures received.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 25 February 2019 Resolved
Replace light covers in E/R.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Picture recieved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 25 February 2019 Resolved
Cap overboard discharge in void 4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 4 March 2019
Resolution: Picture received.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 25 February 2019 Resolved
Remove wire from forward deck light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 4 March 2019
Resolution: Picture received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2019 Resolved
Replace aft lifering on 2nd deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 4 March 2019
Resolution: Receipt received.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2019 Resolved
Secure J-box under bridge wing port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 4 March 2019
Resolution: Picture received.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 February 2019 Resolved
Repair hole in 2nd deck near stariwell and bulkhead hole exterior stbd side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 20 March 2019
Resolution: Received pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 February 2019 Resolved
Move work jackets from life jacket stowage location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 4 March 2019
Resolution: Picture received.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2019 Resolved
Properly wire fan installed in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 5 March 2019
Resolution: Picture received.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 February 2019 Resolved
Securely mount speaker stbd side 2nd deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 5 March 2019
Resolution: Picture received.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 February 2019 Resolved
Repair holed deck on stbd side IVO paddle wheel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 19 March 2019
Resolution: Received pictures.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 July 2018 Resolved
Provide NDT documentation for hull repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2018 Resolved
Provide tech rep's report of installation and load test of new generators.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2018 Resolved
Acquire MSC approval for new generator installations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2018
Resolved 28 January 2019
Construction/Loadline › Hull › Weld
Issued 23 April 2018 Resolved
Make permanent repairs to vessels hull interior and exterior. Crew shall test and log high water alarm in void #3 daily, prior to operations. Crew shall perform and log hourly rounds in void #3 to check condition of temporary repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 26 July 2018
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 29 September 2017 Resolved
Portside engine controls are un-responsive for reverse and forward propulsion. Investigate the cause of casualty on portside engine. Submit a technician report to include results of a satisfactory underway sea trials to the attending Marine Inspector after making proper repairs.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2017
Resolution: Reduction gear throttle cable is repaired.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 18 April 2017 Resolved
Identify and repair cause of MDE loss of control.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 April 2017 Resolved
Make repairs to damamged hand rails.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 2 June 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 18 April 2017 Resolved
Provide plans for approval to MSC for the propulsion control system (ZF Micro Commander) installation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 5 April 2019
Resolution: Outstanding def cleared from previous inspection.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 18 April 2017 Resolved
Demonstrate proper operation of the vessels propulsion control system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 12 June 2017
Engineering › Pressure Vessel › Support
Issued 12 October 2016 Resolved
Properly secure water potable water heater located in compartment #5.
Due 17 January 2017
Resolved 3 February 2017
Engineering › Pressure Vessel › Relief Valve
Issued 12 October 2016 Resolved
Replace relief valve on small pressure vesssel located in compartment #5, valve shall be rated at 150psi or less.
Due 12 January 2017
Resolved 8 February 2017
Electrical › Electric Supply System (service) › Cable
Issued 22 February 2016 Resolved
Ensure all battery cables are approved for marine service! Several battery cables were found to be welding cables. This deficiency was noted during the 2015 annual exam. Although some had been renewed with approved cables, others were not.
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 12 December 2016
Engineering › Lubricating Oil Service System › Gauge
Issued 22 February 2016 Resolved
STBD main engine oil pressure gauge, located on bridge, is not functioning. Repair or renew gauge.
Due 22 July 2016
Resolved 12 December 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2016 Resolved
Several dead end wires/cables were noted; remove non-functioning circuits.
Due 22 March 2016
Resolved 12 December 2016
Engineering › Thrusters › Hose
Issued 22 February 2016 Resolved
Devise better support system for BOW prop hydraulic hoses located in void #4.
Due 22 March 2016
Resolved 12 December 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.