Records from 1991 to 2005. Most recent: inspection, 27 January 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
27 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2281554
9 December 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1714773
17 October 2001
Hull Examination · Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1448367
25 October 2000
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 823557
14 September 2000
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1441726
26 October 1999
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1127954
20 September 1999
Hull Examination · Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 785747
4 December 1998
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 806611
2 October 1998
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1455641
14 October 1997
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1115000
24 September 1997
Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1406192
30 April 1997
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1093182
19 March 1997
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1098551
18 November 1996
Hull Examination · Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1359260
20 September 1995
Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1182566
28 September 1994
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 864501
29 September 1993
Hull Examination · Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 845162
8 September 1992
Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 940273
4 September 1991
Initial Certification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 957696
Navigation
Issued 14 September 2000
Resolved
PROVE PROPER OPERATION OF NAVIGATIONAL LIGHTS AS PER 46 CFR 183.420 PRIOR TO OPERATING THE VESSEL AT NIGHT.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Lifesaving
Issued 20 September 1999
Resolved
Ring bouy beckets deteriorated. Renew ring buoy beckets in accordance with46 CFR Subchapter Q or replace ring buoy to the satisfaction of the cognizant OCMI not later than 04OCT99.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Construction/Loadline
Issued 20 September 1999
Resolved
"V" style longitudinal exterior hull keel guard, stbd side aft is holed, therby allowing unanticipated entry of water between the hull and keel guard and non-inspectable hull corrison. Must repair.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Engineering
Issued 20 September 1999
Resolved
Stbd side fuel line deteriorated in non-adherence with 46 CFR 182.458. Replace fuel line to the satisfaction of the cognizant OCMI not later than 04 OCT 1999.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Documentation
Issued 20 September 1999
Resolved
Lifejacket donning instructions not posted in non-adherence with 46 CFR 185.516. Post lifejacket donning instructions to the satisfaction of the cognizant OCMI not later than 04OCT99.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Documentation
Issued 20 September 1999
Resolved
Emergency instructions not posted in non-adherence with 46 CFR185.508. Post emergency instructions to the satisfaction of the cognizant OCMI not later than 04OCT99.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Lifesaving
Issued 2 October 1998
Resolved
Lifejackets (12) have damaged retroreflective tape. Repair/ Replace to thesatisfaction of USCG IAW 46 CFR 185.604 (h).
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Engineering
Issued 24 September 1997
Resolved
Replace all flexible fuel lines IAW 46CFR182.720(e)(3)(ii) NLT 24OCT97.
Condition: Unknown
Due 24 October 1997
Resolved 16 October 1997
Engineering
Issued 24 September 1997
Resolved
Replace all flexible hydraulic lines IAW 46CFR182.720(e)(3)(ii) NLT 24OCT97.
Condition: Unknown
Due 24 October 1997
Resolved 16 October 1997
Engineering
Issued 24 September 1997
Resolved
Replace trim tab brace IAW 46CFR176.700 NLT 24OCT97.
Condition: Unknown
Due 24 October 1997
Resolved 16 October 1997
Construction/Loadline
Issued 18 November 1996
Resolved
Make proper repairs to the bottom hull fracture approximately two feet below the second port side scupper. Repair to be completed to the satisfaction of the attending USCG marine inspector.
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Documentation
Issued 18 November 1996
Resolved
Provide proper drug testing program, meeting the requirements of 46 CFR Subpart 16. To be completed to the satisfaction of the attending U.S. Coast Guard marine inspector.
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996