Records from 1991 to 1995. Most recent: inspection, 25 October 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
25 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 874291
31 January 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429997
12 December 1994
Quarterly Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1454141
9 September 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 449129
9 September 1994
Quarterly Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1463129
12 July 1994
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417666
9 June 1994
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1428352
17 May 1994
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 859805
1 March 1994
Quarterly Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1354604
30 December 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1160860
20 December 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 461073
3 December 1993
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467396
2 December 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 529193
3 November 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 680303
21 October 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 148668
30 August 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 360580
30 August 1993
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387386
17 August 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 680304
8 August 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 42145
4 June 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1138317
26 May 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 680305
24 May 1993
Certificate of Compliance
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387352
21 May 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 358281
3 May 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 680302
30 April 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 525843
31 January 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 513620
14 January 1993
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1136181
27 October 1992
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 951062
28 July 1992
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1266755
9 July 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 351766
4 June 1992
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1257689
28 May 1992
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1255710
5 May 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 350939
5 May 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1258320
3 April 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1419025
31 March 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 80800
10 January 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 959416
10 January 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1136488
3 October 1991
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 959775
9 September 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 679676
30 July 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 345792
29 July 1991
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 937467
Electrical
Issued 12 December 1994
Resolved
Remove old inoperative emergency generator gauges on old control panel in emergency generator room.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 9 September 1994
Resolved
PLACE DOUBLE NUTS ON RUDDER INDICATOR LINKAGE IN STEERING GEAR ROOM.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Accommodation/Occupational Safety
Issued 9 September 1994
Resolved
REPAIR DISCHARGE LINE FOR OVERBOARD SEWAGE; OVERBOARD SEWAGE LINE HAS SOFT PATCH.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Construction/Loadline
Issued 9 September 1994
Resolved
RENEW BILGE DISCHARGE GAUGE ON BOTH BILGE PUMPS.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Navigation
Issued 9 September 1994
Resolved
REPAIR REMOTE RUDDER INDICATORS TO SHOW PROPER DEGREE'S ON BRIDGE AND PORT/STBD BRIDGE WING. ENSURE COVERS ARE ON AFTER REPAIRS.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Electrical
Issued 9 September 1994
Resolved
REPAIR J/W GAUGE ON EMERGENCY GENERATOR TO SHOW PROPER TEMPERATURE.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Fire Fighting
Issued 9 June 1994
Resolved
REMOVE CARPET ROLLS FROM STAIRTOWER. IMPROPER STOWAGE AREA.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Accommodation/Occupational Safety
Issued 9 June 1994
Resolved
CLEAR STORES FROM THE STBD ENGINE ROOM PASSAGE; BOXES IN PASSAGEWAY.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Fire Fighting
Issued 9 June 1994
Resolved
ENSURE THAT FSD #19 AND 20 (FWD LOUNGE) WILL CLOSE AGAINST VENTILATION DRAFT.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Accommodation/Occupational Safety
Issued 9 June 1994
Resolved
REMOVE STORES AND GARBAGE FROM GALLEY ACCESS, STBD SIDE, B DECK (FWD).
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Construction/Loadline
Issued 9 June 1994
Resolved
REMOVE OIL FROM BILGES IN SPRINKLER PUMP AND STEERING GEAR ROOMS.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Electrical
Issued 9 June 1994
Resolved
PROVIDE AND INSTALL A COVER FOR THE TRANSFORMER BOX, PORT SIDE, IN STEERINGGEAR ROOM.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Lifesaving
Issued 9 June 1994
Resolved
RENEW AS ORIGINAL THE FORWARD SEAT AREA WHERE ROTTED, LIFEBOAT # 8.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Electrical
Issued 9 June 1994
Resolved
INSTALL METAL RETAINING CLIPS ON THE WIRING RUNS IN THE OVERHEAD THROUGHOUTTHE ENGINEROOM.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Accommodation/Occupational Safety
Issued 9 June 1994
Resolved
CLEAR THE STANDING WATER, C DECK FORWARD. (STOPPED DRAIN IN WELL BOX, STANDING WATER IN CLOSET)
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Fire Fighting
Issued 9 June 1994
Resolved
REMOVE PHOTO SHOP FROM THE STAIRTOWER
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Fire Fighting
Issued 9 June 1994
Resolved
INSTALL A B-0 DOOR ON STORES AREA, C DECK, FWD.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Electrical
Issued 9 June 1994
Resolved
REPAIR THE ELECTRIC SWITCH BOX, GRAY WATER O/B PUMP, IN THE ENGINE ROOM.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Electrical
Issued 9 June 1994
Resolved
PROVE THE PROPER OPERATION OF THE EMERGENCY BATTERIES FOR LIGHTING, EMERGENCY SYSTEMS. 30 MINUTE TEST MINIMUM.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Electrical
Issued 9 June 1994
Resolved
FIX THE COVER FOR THE ELECTRICAL CONTROLLER BOX FOR SANITATION FRESH WATER PUMPS IN THE ENGINEROOM.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Electrical
Issued 9 June 1994
Resolved
FIX THE JACKET WATER COOLING RESERVIOR LEAK FOR THE #4 S/S GENERATOR.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Engineering
Issued 9 June 1994
Resolved
REPAIR THE HOLED SALT WATER O/B DISCHARGE ELBOW FOR COOLING WATER, MAIN ENGINE.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Accommodation/Occupational Safety
Issued 9 June 1994
Resolved
REPAIR THE HOLED VENT PIPE, BALLAST TANK VENT, PUMP ROOM.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Construction/Loadline
Issued 1 March 1994
Resolved
VESSEL HAS SIX WATERTIGHT DOORS. BY AGREEMENT WITH USCG, WTD AT FRAME 34 WAS TO BE SECURED PERMANENTLY. ON USCG EXAMINATION 01 MAR 94, WTD WAS NOTED TO BE READILY OPENED AND IN USE BY CREW. VESSEL HA-MIARS > FIVE WTDS, ALL MUST BE TYPE 3, OPERATED FROM BRIDGE. (SOLAS II-2, 15.11.1)
Condition: Unknown
Due 1 March 1994
Resolved 1 March 1994
Construction/Loadline
Issued 3 December 1993
Resolved
REPAINT HULL MARKNGS FOR LOADLINE IN CONTRASTING COLOR FROM HULL.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Electrical
Issued 3 December 1993
Resolved
REPAIR BROKEN GAUGE ON PANEL BOX FOR E-GENERATOR.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Accommodation/Occupational Safety
Issued 3 December 1993
Resolved
REMOVE ALL DOUBLE KEYED LOCKS ON ALL EXITS, IE: GLASS DOORS LEADINGS FROM PASSENGER DINING AND LOUNGE AREAS.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Fire Fighting
Issued 3 December 1993
Resolved
REPAIR CLOSURE INDICATOR LIGHT ON BRIDGE FSD PANEL.
Condition: Unknown
Due 9 December 1993
Resolved 9 December 1993
Electrical
Issued 3 December 1993
Resolved
PROPERLY BLOCK AND BRACE E-GENERATOR BATTERIES.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Electrical
Issued 3 December 1993
Resolved
REPLACE E-GENERATOR FUEL TANK VENT SCREEN. TANK LOCATED ON SUN DECK ABOVE E-GEN SPACE. VENT SCREEN MISSING.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Electrical
Issued 3 December 1993
Resolved
CLEAN DIESEL FUEL SPILLED ON SIDE OF E-GENERATOR PRIOR TO OPERATION.
Condition: Unknown
Due 9 December 1993
Resolved 9 December 1993
Accommodation/Occupational Safety
Issued 3 December 1993
Resolved
REMOVE ALL COMBUSTIBLES FROM FAN SPACE #5 AND ALL OTHER FAN SPACES AS APPLICABLE.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Lifesaving
Issued 30 August 1993
Resolved
PROVIDE DOCUMENTATION TO PROVE PROPER SERVICING OF ALL INFLATABLE LIFERAFTS.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993
Electrical
Issued 30 August 1993
Resolved
PROVIDE MISSING COVER FOR ELECTRICAL BOX IN STEERING ROOM.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993
Fire Fighting
Issued 30 August 1993
Resolved
CLEAR IMPINGEMENT OF FIRE STATION DOOR #3 SO IT MAY OPEN FREELY.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993
Lifesaving
Issued 24 May 1993
Resolved
REMOVE LOCKS FROM PYRO LOCKER.
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Accommodation/Occupational Safety
Issued 24 May 1993
Resolved
remove excess stores from fan room port side forward of bunker station _x001C_ properly stow portable fire ext, and fix electrical wiring. In stbd side fan space, fix electrical wiring and stow 50lb refrigerant bottles.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Electrical
Issued 24 May 1993
Resolved
REMOVE EXTENSION CORD ON DECK NEAR STAGE.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Accommodation/Occupational Safety
Issued 24 May 1993
Resolved
REMOVE COMBUSTIBLES FROM STAIRTOWERS.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Accommodation/Occupational Safety
Issued 24 May 1993
Resolved
PROVIDE ADEQUATE STORAGE FOR ALL PRESSURIZED BOTTLES.
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Lifesaving
Issued 24 May 1993
Resolved
PROPERLY SECURE HYDRO-RELEASING GEAR IN WAY OF STBD SIDE LIFERAFT INSTALLATIONS.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Fire Fighting
Issued 24 May 1993
Resolved
fire screen door #4 sticks.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Electrical
Issued 24 May 1993
Resolved
PROVIDE GASKET FOR BATTERY VENT CLOSURE AND PROPERLY BRACE BATTERY FROM MOVEMENT.
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Electrical
Issued 24 May 1993
Resolved
PROPERLY TERMINATE ALL BARE ELECTRICAL WIRES IN MACHINERY SPACE ENTRANCE.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Electrical
Issued 24 May 1993
Resolved
REPAIR OVERHEAD LIGHT IN WAY OF LUBE OIL PURIFYING AREA.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Construction/Loadline
Issued 24 May 1993
Resolved
remove oil from bilges.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Fire Fighting
Issued 24 May 1993
Resolved
replace smashed gauges on main fire pump.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Fire Fighting
Issued 24 May 1993
Resolved
remove lock from fsd #30
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Navigation
Issued 21 May 1993
Resolved
U.S. CHART 18773, 33RD ED., NOT CURRENTLY CORRECTED; MISSING ALL APPLICABLECORRECTIONS TO DATE.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Navigation
Issued 21 May 1993
Resolved
U.S. COAST PILOT, VOL 7, 1993 OR IT'S EQUIVALANT NOT ON BOARD.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Navigation
Issued 21 May 1993
Resolved
VSL FAILED TO NOTIFY COTP SAN DIEGO OF ARRIVAL WITH HAZARDOUS CONDITION ONBOARD.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Navigation
Issued 21 May 1993
Resolved
U.S. TIDE TABLES, 1993, WEST COAST OF NORTH AMERICA, NOT ON BOARD.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Navigation
Issued 21 May 1993
Resolved
U.S. TIDAL CURRENT TABLES, 1993, WEST COAST OF NORTH AMERICA, NOT ON BOARD.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Navigation
Issued 21 May 1993
Resolved
VSL DID NOT HAVE AN OPERATIONAL GYROSCOPE ON BOARD.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Navigation
Issued 9 July 1992
Resolved
U.S. COAST PILOT, 1990, VOL VII, PACIFIC COAST, NOT CURRENTLY CORRECTED; MISSING ALL APPLICABLE CORRECTIONS TO DATE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Navigation
Issued 9 July 1992
Resolved
U.S. LIGHT LIST, 1991, VOL VI, PACIFIC COAST, NOT CURRENTLY CORRECTED; MISSING ALL APPLICABLE CORRECTIONS TO DATE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Navigation
Issued 5 May 1992
Resolved
The vessel crew failed to provide evidence of having the most recent supplement to the Coast Pilot.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Navigation
Issued 5 May 1992
Resolved
Crew failed to provide evidence of having the most current light list onboard.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Documentation
Issued 3 April 1992
Resolved
AMMEND OIL TRANSFER PROCEDURES TO INDICATE NO FUEL OIL TO BE CARRIED IN PORT SIDE # 4 DOUBLE BOTTOM TANK.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Construction/Loadline
Issued 3 April 1992
Resolved
PROVIDE COPY OF SURVEYORS REPORT OF DAMAGE AND REPAIRS TO COMPLY WITH U.S. CODE FOR INVESTIGATING CASUALTIES ON PASSENGER VESSELS CARRYING U.S. CITIZENS. PROVIDE COPY OF FOLLOW-UP SURVEYS CONDUCTED IN ACCORDANCE WITH CLASS CONDITIONS.(SURVEYS OF GROUNDING DAMAGE TO HULL P/S FRAME 78-79)_x001C_
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Engineering
Issued 30 July 1991
Resolved
VESSEL HAD NO PROOF OF ANNUAL PRESSURE TEST FOR FIXED OIL TRANSFER PIPING AS REQUIRED BY 33 C.F.R.156.170
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Engineering
Issued 30 July 1991
Resolved
VESSEL HAD NO POLLUTION PLACARD POSTED AT BUNKERING STATIONS OR MACHINERY SPACES
Condition: Unknown
Due 3 April 1992
Resolved 21 May 1992
Engineering
Issued 30 July 1991
Resolved
OIL TRANSFER PROCEDURES MISSING PRODUCT TRANSFERED, PROCEDURES FOR EMPTYINGCONTAINMENT, DUTIES OF PERSONNEL, PROC. FOR TOPPING OFF, AND MEANS OF COMMUNICATION
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Navigation
Issued 30 July 1991
Resolved
LIGHT LIST WAS NOT CURRENT, LAST UPDATE WAS 07/89
Condition: Unknown
Due 3 April 1992
Resolved 21 May 1992
Navigation
Issued 30 July 1991
Resolved
VESSEL FAILED TO HAVE BLOCK DIAGRAM OPERATING INSTRUCTIONS FOR STEERING GEAR CHANG-OVER
Condition: Unknown
Due 3 April 1992
Resolved 21 May 1992