MAURY USCG vessel records Sign in
← All vessels

ROWAN

ROWAN is a 1991 tank ship. The Coast Guard has recorded 29 inspections since 1991, most recently in September 2007, along with 15 deficiencies and 2 operational controls.

Records from 1991 to 2007. Most recent: inspection, 3 September 2007.

Built
1991
Last inspected
3 September 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8814421 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
366992
Flag
BAHAMAS, THE
—
Maury page id
psix-366992

Inspections, by type

…with no type recorded14
Years with a record 13 calendar years (1991–2007)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it24731 - Regulatory (Subpart C or D), Gross Ton
12652 - Regulatory (Subpart C or D), Net Ton
53096 - Displacement, Ton
44646 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KIMBERLY Industrial Vessel · MISLE 733322 · 24 December 2004 · activity 2265478

Inspection history · 29

3 September 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3047402
3 September 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3047429
2 September 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3045435
2 September 2007 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3056730
24 July 2007 MARPOL Annex I Examination · ISPS II Exam · COC-TVE Annual · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3006042
22 April 2006 Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · COC-TVE Renew · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2618465
24 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2265478
27 June 2004 Ballast Water Examination · PII Safety Exam · Random ISPS/MTSA/PSC
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2112674
24 June 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2110088
17 June 2004 MTSA/ISPS Verification · Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2101294
11 June 2003 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1805491
29 December 2002 MARPOL Annex I Examination · Tank Vessel Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1722039
25 September 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 282402
25 September 2000 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1053697
28 February 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 275002
21 September 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1122127
23 August 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 431964
23 August 1999 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1115111
23 July 1998 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 795142
22 July 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 418477
31 January 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 400169
29 October 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 384984
29 October 1995 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 879171
10 February 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 374945
11 May 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 367202
10 May 1994 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385235
27 May 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 461512
27 August 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 346345
27 August 1991 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004943

Deficiency record · 15

Navigation › Collision/Grounding Avoidance › Radar
Issued 3 September 2007 Resolved
While transiting the Lower Mississippi River the vessel's Radar experienced a scanner malfunction.
Due 3 September 2007
Resolved 3 September 2007
Resolution: Received Tech report from [name withheld] Marine satisfying requirement
Engineering › Compressed Air System (start air) › Valve
Issued 3 September 2007 Resolved
While attempting to start Main Engine starting air system valve no 26. The valve experienced leakage thus terminating the operation of start up.
Action required: 705 - Other - as specified
Due 3 September 2007
Resolved 3 September 2007
Resolution: Received class report from [name withheld] attesting to the proper operation of start air valve and main engine thus satisfying requirements.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 June 2004 Resolved
Remove or terminate electrical wiring on navigation bridge that is not in use IAW with SOLAS 74 Ammended Ch II-1 Reg 45. Make repairs to the satisfaction of local OCMI.
Due 20 July 2004
Resolved 27 June 2004
Resolution: While onboard CGMI reviewed class report from vessel and cleared deficiency.
Fire Fighting › Means of Escape › Doorways
Issued 17 June 2004 Resolved
Ensure all doors in emergency escape trunk in engine room are self-closing IAW SOLAS 74 Ammended Ch II-2 Reg 47. Make repairs to the satisfaction of local OCMI
Due 20 July 2004
Resolved 27 June 2004
Resolution: While onboard CGMI witnessed repairs and cleared deficiency
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 17 June 2004 Resolved
EEBD in engine control room was empty. Ensure all required EEBDs are at required levels.
Due 21 June 2004
Resolved 21 June 2004
Resolution: A spare EEBD was pu into service.
Deck/Cargo › Cargo Heating
Issued 29 December 2002 Resolved
Make permanent repairs to the leaks iwo the deck steam lines
Action required: 15 - Rectify deficiencies by next port
Due 29 December 2002
Resolved 11 June 2003
Resolution: Cleared by class surveyor.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 29 December 2002 Resolved
Make permanent repairs to the failed gasket iwo the #2 cargo at valve CD47/49/50/51
Action required: 15 - Rectify deficiencies by next port
Due 29 December 2002
Resolved 11 June 2003
Resolution: Cleared by class surveyor.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 29 December 2002 Resolved
Conducted a hydrostatic test of the entire cargo block piping assembly prior to returnig transfer lines into service
Action required: 15 - Rectify deficiencies by next port
Due 29 December 2002
Resolved 11 June 2003
Resolution: Cleared by class surveyor.
Navigation
Issued 25 September 2000 Resolved
Add warning statement to Maneuvering Fact Sheet IAW 33CFR164.35.
Condition: Unknown
Due 26 September 2000
Resolved 29 December 2002
Resolution: corrected
Fire Fighting
Issued 28 February 2000 Resolved
Ensure Fire Control Plans throughout ship have proper symbology as per IMO resolution A.654(16). SOLAS 74 Amended II-2 Reg 20.
Condition: Unknown
Due 30 September 2000
Resolved 30 September 2000
Deck/Cargo
Issued 23 August 1999 Resolved
Install audible and visual cargo tank overfill alarms. Alarms must be audible and visable from the cargo deck area.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Electrical
Issued 23 August 1999 Resolved
Lighting located at access to paint locker and pump room are not explosive-proof.
Condition: Unknown
Due 27 February 2000
Resolved 27 February 2000
Fire Fighting
Issued 23 August 1999 Resolved
Fire hydrant hose locking device, located starboard lifeboat deck, does notfunction properly.
Condition: Unknown
Due 27 February 2000
Resolved 27 February 2000
Deck/Cargo
Issued 22 July 1998 Resolved
INSTALL AN AUDIBLE AND VISUAL ALARM THAT CAN BE SEEN FROM THE CARGO DECK AREA AND BE IDENTIFIED AS THE "TANK OVERFILL ALARM" FOR ALL CARGO TANK OVERFILL DEVICES.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Deck/Cargo
Issued 22 July 1998 Resolved
MAKE PUMP ROOM AVAILABLE FOR INSPECTION BY COAST GUARD MARINE INSPECTOR AT NEXT U.S. PORT. PUMP ROOM NOT INPSECTED BY MSO GUAM DUE TO LACK OF MARINE CHEMIST.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.