MAURY USCG vessel records
← All vessels

STOLT FOCUS

STOLT FOCUS is a 2001 tank ship. The Coast Guard has recorded 13 inspections since 2017, most recently in April 2025, along with 2 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 12 April 2025.

Built
2001
Last inspected
12 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 April 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9214305
Flag
CAYMAN ISLANDS
Maury page id
psix-36710

Documentation record

Tonnage as PSIX records it37467 - Dead Weight, Ton
48498 - Displacement, Ton
23190 - Convention (Subpart B), Gross Ton
11915 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANDREW K Towing Vessel · MISLE 349103 · 19 July 2017 · activity 6333388

Inspection history · 13

12 April 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8109053
19 August 2022 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7537882
23 May 2021 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7203858
19 February 2020 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6911625
26 February 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6631733
8 February 2019 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6622312
8 February 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6624695
9 October 2018 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6557281
9 October 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6595856
1 October 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6552297
27 April 2018 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6400452
19 July 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333388
25 February 2017 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6090316

Deficiency record · 2

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2018 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to other hazards. Submit for review a classification society report to [email withheld] attesting to the cause of the equipment failure, that authorized temporary or permanent repairs have been completed, and that the vessel's full and normal maneuverability has been restored. 74SOLAS(14CONS) II-1/26
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 October 2018
Resolution: Received class report, attesting to the satisfactory operation of the Main Propulsion now fitted with approved fresh water gasket packing.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 9 October 2018 Resolved
The company should establish procedures for the implementation of corrective action, including measures intended to prevent recurrent. Additionally in meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known. As documented in the vessel's safety management system [NON CONFORMANCE HANDLING CIM-PP12-4.3-WI] a non-conformance can be issued due to underperformance of purchased goods [in this case, gasket P/N 90810-0063 107]. Upon request by PSCO, no documentation pertaining to a raised non-conformity could be provided by the crew. Upon statements by engineering crew [chief engineer, second engineer] an unapproved rubber packing gasket had been utilized [in lieu of designed manufactured part] since August 2017 on all cylinders, and most recently replaced with a new unapproved rubber gasket in September 2017 [for the #1 cylinder]. 74SOLAS(14CONS)IX3.1 ISM CODE 9.2/ISM CODE 10.2.2 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2018
Resolved 2 November 2018
Resolution: Company provided internal audit results attesting to ship and fleet wide training of the utilization of correct OEM gaskets.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.