Records from 2002 to 2012. Most recent: inspection, 17 May 2012.
Inspection history · 28
17 May 2012
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4313660
4 February 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3939378
26 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3933570
24 January 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3932308
20 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3929737
15 December 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3650373
14 December 2009
MARPOL Annex VI Survey · PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3646933
7 June 2006
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2672954
10 May 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2645912
10 May 2006
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2646045
3 December 2005
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2545111
18 March 2005
ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2312867
7 September 2004
NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2189060
18 July 2004
Random ISPS/MTSA/PSC
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2136964
5 July 2004
ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2122446
14 May 2004
MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2072823
17 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2026442
15 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2026028
12 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2030169
17 February 2004
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2001722
19 December 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1968452
9 September 2003
Re-Inspection · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1900848
15 April 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1774527
2 January 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1725218
24 October 2002
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1698567
24 October 2002
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1713254
17 August 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1662566
3 January 2002
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1475208
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 24 January 2011
Resolved
2100-MARPOL RELATED OPERATIONAL- After the survey of the ship has been completed, no change shall be made in the, equipment covered by the survey without sanctions of the administration. Vessel has configured a pumping arrangement from the sewage system into the #6 ballast tank. Class shall attest to the arrangement of the ballast tank and sewage system. SOLAS2001cons I-11
Action required: 705 - Other - as specified
Due 24 January 2011
Resolved 25 January 2011
Resolution: Received class report from [name withheld] stating all outstanding deficiencies have been rectified. The class report stated: That the vessel discharged the sewage form the ballast, the sewage line was disconnected, and the ballast tank was cleaned
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 24 January 2011
Resolved
0100-Documentation- Each transfer pipe system including each metal hose must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Crew could not provide documentation stating the bunker lines were tested in accordance with 33CFR156.170. 33CFR156.170 DECLINED THE CLASS REPORT SEE NARRATIVE FOR DETAILS
Action required: 705 - Other - as specified
Due 24 January 2011
Resolved 4 February 2011
Resolution: Received Master''s statement satisfying the requirement.
Construction/Loadline › Hull › Hull Plating
Issued 24 October 2002
Resolved
Request class to enter #5 and #6 starboard upper wing ballast tank and provide marine inspector with the procedures to fix hull damage including damage to starboard outside A and B deck. Class to attest to the watertight integrity and satisfaction of repairs in accordance with class procedures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2002