Records from 2003 to 2024. Most recent: inspection, 7 August 2024.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 August 2024
Resolved
** Amended 09AUG24 **
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or Coastwise trade, must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged.
Vessel did not have a current valid COD on board. An application for COD renewal was received by NVDC on 05AUG24, but has yet to be processed.
Produce proof/copy of valid COD once received.
46 CFR 67.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 23 August 2024
Resolution: Received emailed copy of valid COD from vessel operator and verified information in MISLE vessel details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2024
Resolved
Connections must be made to battery terminals with permanent type connectors.
MI discovered exposed conductor wires at the battery terminal connection for the positive battery cable leading to the starboard generator.
Fit proper terminal connector on the battery cable.
46 CFR 183.350(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 8 August 2024
Resolution: Received photo evidence of properly installed terminal connector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI witnessed successful ground detection with volt meter from individual switchboard power connections (at single common bus bar) to grounded location on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
Dead ends wires were discovered in the galley distribution panel.
46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified no dead-end wires present in distribution panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
Discovered 2 circuits ganged to singular branch circuit protection in the galley and engine room distribution panels.
46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified no double-ganged wires being used in distribution panel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2023
Resolved
All life floats must be of an approved type.
Marine inspector observed 02 life floats stowed on the 3rd deck, aft, had significant wear and were not in serviceable condition.
46 CFR 180.10-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified new proper installation of power receptacles in pilot house, eliminating the use of Daisey chained extension cords.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
All equipment, including switches, fuses, lamp holders, etc., must be suitable for the voltage and current utilized.
Batteries in the engine room were leaking fluid due to charging at a higher rate than specified.
46 CFR 183.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified installation of all new 12-volt batteries and clean receptacles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections.
Power supply for the oven in the galley was covered in grease creating a fire hazard.
46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified grease cleaned up behind oven near power sources.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections.
The plug for the galley fridge was bent and exposed creating a fire hazard.
46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified that the refrigerator had been pulled out enough from the wall, as to not cause bending and kinking of the power cable at the outlet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 May 2023
Resolved
S and L. Each major generator and motor shall be fitted with a nameplate of corrosion resistant material.
Port side generator's nameplate was covered in paint and not legible.
46 CFR 183.10-5(a)
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 5 September 2023
Resolution: Verified new nameplate installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 May 2023
Resolved
S and L. Each major generator and motor shall be fitted with a nameplate of corrosion resistant material.
Fire pump's nameplate was covered in paint and not legible.
46 CFR 183.10-5(a)
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 5 September 2023
Resolution: Verified new nameplate installed.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 17 May 2023
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1 inch letters: "Emergency Exit, Keep Clear", unless such markings are deemed unnecessary by the Officer in Charge, Marine Inspection.
Port and starboard emergency exit doors on the slots machine deck did not have visible emergency exit signage due to slot machine obstruction.
46 CFR 185.30-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified proper signage for emergency escape routes were posted, both port and starboard, near the aft exits of the main casino deck, in a location they could be seen across the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2023
Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury.
Port main diesel engine shaft seal had a constant stream leak.
46 CFR 182.01-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified shaft seal had been tightened to slow "normal" shaft gland seepage to an acceptable level.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2023
Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury.
Port and starboard main diesel engines were leaking raw water out of their raw water manifolds.
46 CFR 182.01-5(a)
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 5 September 2023
Resolution: Verified new water hoses installed on main engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 May 2023
Resolved
S and L. A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator that is in operation.
Port generator was missing it's voltmeter.
46 CFR 183.10-5(g)
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 5 September 2023
Resolution: Verified new voltmeter installed.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 May 2023
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances:
(1) Where the internals of the vessel are completely concealed, sections of the lining or ceiling may be removed or the parts otherwise probed or exposed so that the marine inspector may satisfy himself as to the condition of the hull structure.
Fixed ballast under the deck in the galley was inaccessible for inspection due to laminate and flooring.
46 CFR 176.25-5(a)(1)
Action required: 705 - Other - as specified
Resolved 14 June 2023
Resolution: MI verified an approx. 16"x8" access hatch had been installed in the galley floor, centerline of vessel, for internal inspection purposes and possible removal of led ballast if necessary.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 May 2023
Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard.
Large build up of grease was found in the ventilation ducts for the oven hood in the galley.
46 CFR 176.25-50(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified grease cleaned up in the ventilation hood.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 May 2023
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage.
Marine inspector observed fire pump pressure gauge not working as designed, and could not verify required PSI.
46 CFR 181.10-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified installation of new pressure gauge at the fire pump location, and witnessed a demonstrated operational pressure of 70 psi.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2023
Resolved
On a vessel on which the number of passengers permitted
on the upper decks is limited by stability criteria...
the maximum number of passengers allowed on the upper
decks must be indicated by a durable marking of numbers
and letters at least one inch in height at the entranceway to each such deck.
Marine inspector observed that the 2nd deck did not have a marking indicating the maximum allowable passengers on that deck.
46 CFR 185.30-3(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified proper signage for passenger capacity (105 persons) in place for the 2nd deck card room.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2023
Resolved
All life floats must be of an approved type.
Marine Inspector observed 02 life floats stowed on the 3rd deck, aft, had significant wear and were not in serviceable condition.
46 CFR 180.10-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 14 June 2023
Resolution: MI verified 02 new life floats were installed onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2022
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used.
Identified supply cable from Center Generator to main switchboard that was cracked and dry-rotted.
705 C: Correct within 7 days.
46 CFR 183.10-20(a)
Action required: 705 - Other - as specified
Due 21 September 2022
Resolved 21 October 2022
Resolution: Owner replaced the Center Generator supply cable (approx. 25 ft in length).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2022
Resolved
Flexible hose shall be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. The hose cover shall be adjudged self-extinguishing as per ASTM D1692, and the hose assembly be capable of withstanding free burning gasoline for 2 1/2 minutes.
Identified fuel oil supply lines exterior shielding missing and metallic sheathing wasted for the port and stbd main diesel engines and center generator.
46 CFR 182.20-40(a)(2)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 21 October 2022
Resolution: Owner replaced all the fuel oil supply lines for the Port, Starboard MDE, and Center Gen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
(a) Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20
(a) Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas tight throughout its length and shall be properly supported by non-combustible hangers or blocks.
Identified pin hole in exhaust piping located on the port side after the exhaust bubbler for the Center Generator. Additionally, hoses are missing hose clamps.
46 CFR 182.20-20(a)
46 CFR 182.15-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 21 October 2022
Resolution: Removed and rewelded the diesel engine exhaust pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
(a) Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20
(a) Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas tight throughout its length and shall be properly supported by non-combustible hangers or blocks.
Identified pin hole in exhaust bubbler piping located for the Starboard Generator. Additionally, hoses are missing hose clamps.
46 CFR 182.20-20(a)
46 CFR 182.15-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 21 October 2022
Resolution: Removed and rewelded the diesel engine exhaust pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
The engine head, block and exhaust manifold shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating.
Identified partially collapsed raw water supply non-metallic hose from the sea strainer to the raw water pump on starboard main diesel engine. Additionally, hose is missing two hose clamps.
46 CFR 182.20-10(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 21 October 2022
Resolution: Replaced hose and clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
The engine head, block and exhaust manifold shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating.
Raw water supply non-metallic hose missing hose clamps.
46 CFR 182.20-10(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 21 October 2022
Resolution: Double hose clamps added.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 September 2022
Resolved
Each inflatable liferaft, inflatable buoyant apparatus, life float, and buoyant apparatus on the vessel on March 11, 1996, may be used to meet the requirements of this part for these survival craft as long as the survival craft is continued in use on the vessel, and is in good and serviceable condition.
MI observed 03 of 04 lifefloats with tears, gouges, and water pockets.
46 CFR 180.15(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 25 October 2022
Resolution: Life floats repair w/ approved kit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight.
MI observed cable penetration located above water tight door in the engine room that was not sealed with multiple wires passing through.
46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 21 October 2022
Resolution: Hole was filled to maintain WTI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 September 2022
Resolved
Examine all accessible parts of the exterior and interior of the hull and the watertight bulkheads…
MI observed water leaking through a hole located in the aft Starboard engine room overhead outboard side. It appears from deck above that it is coming from A/C unit.
46 CFR 176.25-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 21 October 2022
Resolution: Hole Sealed and no evidence of leakage.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 September 2022
Resolved
A weathertight door must be provided for each opening located in a deck house or companionway.
MI observed a quarter inch gap where doors sealing edge meets frame on both port and starboard main deck aft.
46 CFR 179.360(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 25 October 2022
Resolution: Doors Port and Starboard sealed weathertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 September 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] observed a door on the 01 deck secured close with a waterline to a wash station. Alteration was made without notification to the [name withheld] removed the water line
and made door operational.
46 CFR 176.700(a)
Action required: 10 - Deficiency Rectified
Due 14 September 2022
Resolved 14 September 2022
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 September 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
MI observed 168 adult life jackets and COI requires 170 onboard. Two adult life jackets were added bringing total to 170 adult life jackets correcting deficiency on the spot.
46 CFR 180.71(a)
Action required: 10 - Deficiency Rectified
Due 14 September 2022
Resolved 14 September 2022
Resolution: Corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 June 2021
Resolved
A vessel...may not be operated without having on board a valid U.S. Coast Guard Certification of Inspection. Vessel's COI expired on 15JUN21 and a COI must be issued prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2021
Resolved 17 June 2021
Resolution: COI inspection completed. COI issued, deficiency cleared.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 June 2021
Resolved
Each EPIRB must be tested monthly and logged or otherwise documented. The operator has not logged the monthly testing of the EPIRB. 46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 1 July 2021
Resolution: Verified monthly EPIRB logs. Deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 June 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. The chart found onboard was last updated in 2017. Update the chart using LNM or purchase a new chart. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 1 July 2021
Resolution: Verified updated charts IAW latest LNM. Deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 June 2021
Resolved
As appropriate for the intended voyage, a vessel must carry a U.S. Coast Pilot. Provide a 2021 Coast Pilot for the intended voyage. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 1 July 2021
Resolution: Verified presence of 2021 Coast Pilot. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 June 2021
Resolved
Each vessel certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate 50% of the total number of persons permitted onboard. One (22) person lifefloat was found damaged. Three (22) person lifefloats are onboard in serviceable condition. Total number of persons permitted onboard reduced by 38. 46 CFR 180.205(c)
Action required: 705 - Other - as specified
Due 17 July 2021
Resolved 14 September 2022
Resolution: Damaged lifefloat was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2021
Resolved
All unfired pressure vessels shall be Coast Guard approved and installed to the satisfaction of the OCMI in accordance with subchapter F. The pressure relief device for the 200 psi MAWP pressure vessel in the engine room does not have markings to indicate the relief pressure. Replace the pressure relief device with one under 200 psi. 46 CFR 182.10-5 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 28 July 2021
Resolution: The operator installed a 165 psi pressure relief valve on the pressure vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2021
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Threaded plug in the hydraulic tank located in the engine room was found leaking due to improper installation. Re-install plug to prevent tank from leaking.
46 CFR 182.10-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 28 July 2021
Resolution: The operator re-installed the threaded plug to prevent leakage of hydraulic fluid from the tank.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021
Resolved
All electrical installations shall be to the satisfaction of the [name withheld] identified a battery charger connected to engine starting batteries on the starboard side and 24 volt batteries on the port side. Installation of the battery charger was incorrect. Adjustments to the charger for temperature compensation and battery type were not made prior to installation. The batteries were found overcharged and leaking water from the battery. Hydrogen gas was witnessed off gassing from the battery due to overcharge creating an explosive atmosphere in the engine room. Corrosive vapors and liquid from the batteries have destroyed the battery tray. Install battery charger in accordance with the manufacturer manual. Replace battery trays under batteries. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 28 July 2021
Resolution: The operator changed the custom setting on the battery charger to charge the batteries at 27 volts and 0.9 amps. The batteries did not appear to be discharging water anymore and hydrogen gas was not detected using multimeter gas detector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021
Resolved
Conductors shall be protected from overcurrent in accordance with their current carrying capacity using a UL 489 circuit breaker or UL listed fuse (class CC, G, H, J, K, RK1, RK5, and T) in accordance with 46 CFR 183.05-35 and 46 CFR 183.380 (L). The conductor installed between the battery charger and 12V/24V batteries in the port/stbd engine room does not have an overcurrent device installed. Install overcurrent protection on the conductor between the battery charger and batteries in accordance with the conductor's current carrying capacity. 46 CFR 183.05-50(C) AND
46 CFR 183.380 (L)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 30 July 2021
Resolution: The operator replaced the conductors between the battery charger and battery banks with UL marine grade 12 AWG per manufacturer. Class CC UL listed fuses are installed to protect each conductor (3).
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 June 2021
Resolved
A self-propelled vessel of 65 feet or more in length, engaged in commercial service shall have an AIS Class A or B device installed on board. AIS was not found installed on board.
33 CFR 164.46(b)(2)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 8 December 2021
Resolution: Owner installed AIS on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2021
Resolved
A suitable rescue boat shall be required except when a rescue platform, of a design approved by the OCMI, is installed to the satisfaction of the OCMI. The rescue platform landing shall be constructed of expanded metal mesh to reduce the effect of wave action. 46 CFR 180.10-35 and
Local USCG St. PETE OCMI policy
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 1 July 2021
Resolution: Verified rescue platform landing installed with metal mesh to reduce effect of wave action. Deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 June 2021
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: EMERGENCY EXIT, KEEP CLEAR. Identified the emergency exit for the engine space located on the port side without appropriate signage on the main deck. Passengers or crew may unintentionally block this escape from above. Place appropriate signage above the emergency escape from the engine space.
46 CFR 185.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 1 July 2021
Resolution: Verified proper placement of signage above the emergency escape from the engine space. Deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021
Resolved
All electrical installations shall be to the satisfaction of the [name withheld] extension cords were found "daisy chained" together on the 3rd deck creating an electrical hazard. Extension cords were removed by the crew during the inspection. Rectified on this date. 46 CFR 183.01-15
Action required: 10 - Deficiency Rectified
Due 17 June 2021
Resolved 17 June 2021
Resolution: Rectified during the inspection.
Stability › Unintentional Flooding › General
Issued 27 November 2017
Resolved
Potable water tanks leaking water into galley bilge. O/O to provide repair proposal and conduct repairs upon approval.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 5 December 2017
Resolution: Potable water tanks repaired to the satisfaction of the marine inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 November 2017
Resolved
Multiple items missing from first aid kit. O/O to inventory and restock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 5 December 2017
Resolution: All required items present in first aid kit to the satisfaction of the Marine Inspector.
Engineering › Bilge Water Management System › Interface Detector
Issued 27 November 2017
Resolved
High water alarm in forepeak not providing audible indication of flooding at control station. O/O to provide visual and audible alarms for all applicable stations.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 November 2017
Resolved 27 November 2017
Resolution: Bilge high water alarms demonstrate clear audible and visual alarm for all required spaces to the satisfaction of the Marine Inspector.
Engineering › Bilge Water Management System › Interface Detector
Issued 27 November 2017
Resolved
Bilge high water alarm disabled due to nuisance alarms. O/O to provide plan to repair/ remove/ disable obsolete inputs to alarm system causing nuisance fault alarms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 5 December 2017
Resolution: Bilge high water alarms demonstrate clear audible and visual alarm for all required spaces to the satisfaction of the Marine Inspector.
Construction/Loadline › Hull › Bracket
Issued 26 September 2017
Resolved
Repair screens in way of port and stbd bow thruster propellers iaw 46CFR176.25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 September 2017
Resolution: New screens welded to hull.
Fire Fighting › Fire Main › Valves
Issued 26 September 2017
Resolved
Repair seized gate valve for fire main iaw 46CFR181.15-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 September 2017
Resolution: Gate valve repaired.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 26 September 2017
Resolved
Replace 04 sea strainer for generators iaw 46CFR176.25-10
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 September 2017
Resolution: 04 strainers replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 6 June 2017
Resolved
Replace 01 24 inch ring life bouy iaw 46CFR180.70(a).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2017
Resolved 7 June 2017
Resolution: Purchased new 24 inch ring life bouy, provided inspector with pictures.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 June 2017
Resolved
Replace 13 Type 1 adult PFDs iaw 46CFR180.71(a). Passenger count reduced to 157 adults.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 20 June 2017
Resolution: Provided 13 Type 1 PFDs in satisfactory condition.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 June 2017
Resolved
Replace 01 Type 1 child PFD iaw 46CFR180.71(b). Child count reduced to 17 from 18.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 20 June 2017
Resolution: Vessel rep purchased 01 Type 1 child size PFD.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 6 June 2017
Resolved
Install insulation on port + stbd exhaust until point of water cooling iaw 46CFR182.15-15(3).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Exhuast insulation installed to the satisfaction of the attending marine inspector.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2017
Resolved
Install MMSI/GPS in VHF-FM radio iaw 46CFR184.502.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Proved installation of MMSI/GPS to the satisfaction of the attending marine inspector.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 6 June 2017
Resolved
Provide updated navigatio chart + publicatoins to include Coast Pilot, and Light List iaw 46 CFR 184.420.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel Rep gathered full compliment of navigation charts and publications to the satisfaction of the attending marine inspector.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2017
Resolved
Obtain valid Operators Permit (FCC) for master onboard iaw 46CFR184.502.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Captain of vessel has taken test, has 90 day completion certificate.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 June 2016
Resolved
Repair aft outlet on starboard side to satisfaction of Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 14 June 2016
Resolution: Repaired aft interior outlet to satisfaction of Marine Inspector.