MAURY USCG vessel records Sign in
← All vessels

FALCON 1

FALCON 1 is a 1978 freight ship. The Coast Guard has recorded 24 inspections since 1991, most recently in October 2002, along with 36 deficiencies and 4 operational controls, 1 with no removal date recorded.

Records from 1991 to 2002. Most recent: inspection, 9 October 2002.

Built
1978
Last inspected
9 October 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7813418 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
367483
Flag
PANAMA
—
Maury page id
psix-367483

Inspections, by type

…with no type recorded21
Years with a record 7 calendar years (1991–2002)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it5955 - Simplified, Gross Ton
2591 - Simplified, Net Ton
11150 - Displacement, Metric Ton
7309 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

9 October 2002 Deficiency Check · Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1687615
5 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1684907
25 March 2002 Passenger/Freight Vessel Examination
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1494361
9 March 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 401092
15 September 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 395506
2 September 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396063
17 June 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 392365
18 March 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 388933
13 December 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 385826
13 December 1995 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 872415
27 November 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 385198
22 November 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 37720
17 November 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 384926
29 August 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 199135
29 August 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 382241
29 August 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765678
10 November 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 675644
2 November 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 107989
2 November 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 371921
29 October 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1180022
5 April 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 511252
29 March 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357139
26 November 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 347366
24 September 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 346118

Deficiency record · 36

Engineering › Sea-water System (primary cooling)
Issued 28 October 2002 Resolved
Main sea water cooling for the main engine has a temporary patch at T-connection. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2002
Resolved 1 November 2002
Resolution: Received satisfactory Class Report, cleared deficiency.
Electrical › Electric Supply System (service)
Issued 9 October 2002 Resolved
Transformer to turning gear controller is wired externally and exposed. LEGACY COMPONENT DESC: Transformer
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2002
Resolved 10 October 2002
Resolution: Received satisfactory Class Report and attended vessel and verified proper repairs.
Engineering › Sea-water System (primary cooling)
Issued 9 October 2002 Resolved
Emergency generator's installed cooling system was inoperable. A fire hose was rigged to provide cooling. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2002
Resolved 28 October 2002
Resolution: Verified satisfactory repairs.
Engineering › Freshwater System (cylinder head cooling)
Issued 9 October 2002 Resolved
Numerous cooling water leaks on both generators from cylinder heads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 28 October 2002
Resolution: Verified proper repairs and operation of both generators.
Engineering › Freshwater System (jacketwater cooling)
Issued 9 October 2002 Resolved
No. 1 auxiliary cooling water pump removed. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 28 October 2002
Resolution: Received satisfactory Class Report and attended vessel and verified installation.
Fire Fighting › Combustible Materials
Issued 9 October 2002 Resolved
Excessive fuel and oil on machinery and in engine room bilges.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2002
Resolved 28 October 2002
Resolution: Vessel has cleaned engine room bilges and pumped excess into bilge water waste tank.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 October 2002 Resolved
No.1 and No.2 generator turbochargers are missing protective shielding on hot section.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2002
Resolved 10 October 2002
Resolution: Received satisfactory Class Report, cleared deficiency. See attached Class Report #1
Personnel › Certificates/Documents/Licenses
Issued 9 October 2002 Resolved
Vessel's officers do not have flag state endorsements or documentary proof of application for flag state endorsements. LEGACY COMPONENT DESC: STCW Endorsement
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2002
Resolved 28 October 2002
Resolution: Received acceptable proof of Panamanian endorsements to the National licenses.
Personnel › Certificates/Documents/Licenses
Issued 9 October 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2002
Resolved 28 October 2002
Resolution: Chief Engineer replaced, verfied proper license and endorsement. Cleared deficiency.
Documentation › Certificates/Documents
Issued 9 October 2002 Resolved
The Certificate of Class expired July 30, 2002.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2002
Resolved 28 October 2002
Resolution: Vessel was issued a new Certificate of Class from International Register of Shipping.
Construction/Loadline › Structures
Issued 9 October 2002 Resolved
Rudder post void hatch cover is warped and shored close. LEGACY COMPONENT DESC: Scuttle
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2002
Resolved 10 October 2002
Resolution: Received satisfactory Class Report and attended vessel and verified proper repairs.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 9 October 2002 Resolved
No.2 generator lube oil supply and return lines have been replaced with hoses that have been reinforced with steel plates and copper wire wrapped around them.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2002
Resolved 10 October 2002
Resolution: Received satisfactory Class Report and attended vessel and verified repairs.
Fire Fighting › Firemans Outfit
Issued 25 March 2002 Resolved
All firemans outfits are wasted LEGACY COMPONENT DESC: Protective Clothing
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2002
Operations/Management › Drills/Instruction
Issued 25 March 2002 Resolved
Crew unable to perform adaquate fire drill. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2002
Construction/Loadline › Structures
Issued 25 March 2002 Resolved
Repair holes in WTDs and bulkheads on the bridge. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2002
Communications › Radio Communications
Issued 25 March 2002 Resolved
Battery room needs to be thoroughly cleaned. LEGACY COMPONENT DESC: Emergency Source of Power
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2002
Engineering › Bilge Water Management System
Issued 25 March 2002 Resolved
Remove excess oily water from bilge in the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2002
Construction/Loadline
Issued 9 March 1997 Resolved
PROVIDE CLASS STATEMENT ATTESTING TO PERMANENT REPAIRS OF 2" HOLE IN DOUBLEBOTTOM BALLAST TANK #4.6. CLASS EXTENDED REQUIREMENT FROM 13 FEB 97 TO 30 NOV 97.
Condition: Unknown
Due 30 November 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 17 November 1995 Resolved
HYDROLIC LINE HAS SOFT PATCH BY NO.3 HOLD AFT
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Fire Fighting
Issued 17 November 1995 Resolved
INSTRUCTIONS NOT IN LANGUAGE UNDERSTOOD BY CREW.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Deck/Cargo
Issued 17 November 1995 Resolved
VENT RISERS FOR NO.1 HOLD NOT WATER TIGHT, DAWGS CORRODED BEONE USE.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 17 November 1995 Resolved
FIREMAIN HAS A SOFT PATCH BY NO. 3 HOLD, STBD SIDE AFT.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Fire Fighting
Issued 29 August 1995 Resolved
DEMONSTRATE OPERATION OF FORWARD FIRE HYDRANT (BOW) WITH PRIMARY AD EMERGEYFIRE PUMP. PROVIDE CLASS SURVEY REPORT TO U.S. COAST GUARD PRIOR TO VESEL'S DEPARTURE FROM PORT HOUSTON._x001C_ _x001C_
Condition: Unknown
Due 30 August 1995
Resolved 8 September 1995
Lifesaving
Issued 29 August 1995 Resolved
REPLACE O2 MASK FOR MEDICAL OXYGEN KIT. ILO 147
Condition: Unknown
Due 27 December 1995
Resolved 27 December 1995
Engineering
Issued 29 August 1995 Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR. PROVIDE CLASS SURVEYORS REPORT. MARPOL I/9
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Accommodation/Occupational Safety
Issued 29 August 1995 Resolved
REPAIR LIGHT IN BATHROOM HOSPITAL.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Lifesaving
Issued 29 August 1995 Resolved
REPLACE REFLECTIVE TAPE ON PORT STBD LIFEBOATS. SOLAS 60 III/8
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Lifesaving
Issued 29 August 1995 Resolved
PROVIDE ONBOARD TRAINING MANNUAL. SOLAS 74 III/51
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Lifesaving
Issued 29 August 1995 Resolved
PROVIDE ONBOARD INSTRUCTIONS FOR ONBOARD MAITENANCE OF LIFESAVING APPLIANCE. SOLAS 74 III/52
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Engineering
Issued 2 November 1994 Resolved
MAKE REPAIRS TO LEAKING SHAFT TUBE SEAL AS REQUIRED BY CLASS SOCIETY. CORRECT PRIOR TO RETURNING TO U.S._x001C_
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Fire Fighting
Issued 2 November 1994 Resolved
FIRE STATIONS NOT MARKED. MARK FIRE STATIONS AS PRE-INTERM SAFETY EQUIPMENTCERT. CORRECT PRIOR TO 02 FEB 95_x001C_
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Fire Fighting
Issued 29 October 1994 Resolved
FIRESTATIONS LOCATED ON THE MAIN DECK AND THE 02 LEVEL OF THE AFT HOUSE NEED TO BE MADE OPERATIONAL.
Condition: Unknown
Due 29 October 1994
Resolved 29 October 1994
Fire Fighting
Issued 29 October 1994 Resolved
PROVIDE PROOF OF PERIODIC SERVICING OF PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 29 October 1994
Resolved 29 October 1994
Unknown
Issued 29 October 1994 Resolved
VENT. COVERS ON THE AFT HOUSE MISSING.
Condition: Unknown
Due 29 October 1994
Resolved 29 October 1994
Documentation
Issued 29 October 1994 Resolved
EXPIRED SHIP SAFETY EQUIPMENT CERT. SSE ISSUED BY GERMANISCHER LLOYD. AND EXPIRED 14 OCT 94.
Condition: Unknown
Due 29 October 1994
Resolved 29 October 1994
Lifesaving
Issued 29 October 1994 Resolved
PORT SIDE LIFE RARTS (2) TO BE PROVIDED WITH SUITABLE WEAK LINKS.
Condition: Unknown
Due 29 October 1994
Resolved 29 October 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.