Records from 1992 to 2021. Most recent: inspection, 26 May 2021.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
26 May 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7291211
9 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7109146
11 January 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6611113
7 November 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6036732
2 November 2016
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6034245
23 July 2015
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5192743
7 December 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4202675
5 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4201668
8 November 2010
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3885726
9 December 2009
Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3647611
23 March 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3438324
18 December 2007
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3126264
9 January 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2852894
4 March 2005
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2326916
15 December 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2418331
6 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2001766
5 December 2003
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1959372
27 November 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1711292
20 December 2001
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1475410
12 January 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453706
19 February 1999
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411922
16 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800793
29 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783413
7 January 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378253
5 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118912
19 June 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1112494
29 January 1997
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427310
1 February 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360401
4 January 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466379
18 February 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353525
25 February 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376931
22 January 1992
Hull Examination · Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 961737
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 23 July 2015
Resolved
Master was missing Marine Radio operator permit. required vessel rep to " provide master with valid marine radio operator permit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2015
Resolution: Vessel rep provided electronic copy of Captain’s course completion for the license course.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 July 2015
Resolved
Vessel had a stern light in place of its masthead light. required vessel rep to provide a mast head light with required arch of visibility. required to be cleared prior to operation of the vessel at night.
Action required: 705 - Other - as specified
Resolved 24 July 2015
Resolution: Vessel rep provided satisfactory pictures of the new installation.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 23 July 2015
Resolved
Compass deviation table did not have the vessel name or the date it was done. required vessel rep to provide one specific to the vessel dated after any major repairs.
Due 30 July 2015
Resolved 27 July 2015
Resolution: Vessel rep provided satisfactory electronic copy of the vessel''s compass deviation card.
Personnel › Training › First Aid/CPR
Issued 23 July 2015
Resolved
Vessel rep did not have required CPR/First aid training required vessel rep to provide first aid/CPR training for 50% of the crew.
Due 30 July 2015
Resolved 24 July 2015
Resolution: Vessel rep provided satisfactory electronic copy of master''s CPR/First aid certificate.
Engineering › Bilge Water Management System › Pump
Issued 7 December 2011
Resolved
Portable hand pump didn't work
Due 14 December 2011
Resolved 7 December 2011
Resolution: Replaced on the spot
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 January 2007
Resolved
EAP information was not displayed for the vessel crew.
Due 31 January 2007
Resolved 10 January 2007
Navigation › Piloting/Steering › Compass Deviation Table
Issued 9 January 2007
Resolved
The compass deviation table was missing.
Due 31 January 2007
Resolved 10 January 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 January 2007
Resolved
Documentation for drills and lifesaving maintenance was not available.
Due 31 January 2007
Resolved 10 January 2007
Lifesaving › Lifebuoys › Serviceable
Issued 9 January 2007
Resolved
Retroreflective tape was faded beyond use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2007
Lifesaving › Lifefloat › Markings
Issued 9 January 2007
Resolved
The vessel name was no longer visible on the lifefloat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2007
Lifesaving › Lifefloat › Painter
Issued 9 January 2007
Resolved
The painter and water light lines were not secured around the body of the life float.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2007
Stability › Watertight Integrity › General
Issued 9 January 2007
Resolved
Two open drill holes were found in the overhead decking above the lazarette.
Due 31 January 2007
Resolved 10 January 2007
Documentation › Certificates/Documents › Stability Letter
Issued 15 December 2004
Resolved
Provide stability letter with endorsement for exposed routes IAW MORMS CID memo dated 30NOV2004.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Resolution: New stability letter issued.
Construction/Loadline › Hull › Hull Plating
Issued 3 January 2002
Resolved
PRIOR TO VESSEL MOVEMENT COMPLETE REPAIRS TO PORT MAIN DECK, PORT SIDESHELL IWO BOW, AND PORT TRANSOM.
Condition: Unknown
Due 3 January 2002
Resolved 3 January 2002
Engineering › Bilge Water Management System › Valve
Issued 3 January 2002
Resolved
INSTALL CHECK VALVES IN EACH BILGE SUCTION LINE.
Condition: Improper/Lack of Maintenance
Due 3 January 2002
Resolved 3 January 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 January 2002
Resolved
INSTALL PROPER BILGE ALARMS.
Condition: Improper/Lack of Maintenance
Due 3 January 2002
Resolved 3 January 2002
Construction/Loadline › Penetrations
Issued 3 January 2002
Resolved
REPACK PORT SIDE ENGINE ROOM FORWARD BULKHEAD PENETRATIONS.
Condition: Improper/Lack of Maintenance
Due 3 January 2002
Resolved 3 January 2002
Electrical › Lighting (service)
Issued 3 January 2002
Resolved
INSTALL LIGHTING GLOBES ON ALL ENGINE ROOM LIGHTS.
Condition: Improper/Lack of Maintenance
Due 3 January 2002
Resolved 3 January 2002
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 3 January 2002
Resolved
PROPERY SECURE GENERATOR CABLE AT JUNCTION BOX
Condition: Improper/Lack of Maintenance
Due 3 January 2002
Resolved 3 January 2002
Engineering › Steering Gear System › Hydraulic Hose
Issued 3 January 2002
Resolved
PRIOR TO VESSEL MOVEMENT REPAIR HYDRAULIC LEAK IN STEERING GEAR (UNDER PILOTHOUSE CONSOLE).
Condition: Improper/Lack of Maintenance
Due 3 January 2002
Resolved 3 January 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 3 January 2002
Resolved
PROPERLY MOUNT PILOTHOUSE DRY/CHEM EXTINGUISHER
Condition: Improper/Lack of Maintenance
Due 3 January 2002
Resolved 3 January 2002
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 January 2002
Resolved
PROVIDE LIFE JACKET DONNING INSTRUCTIONS THAT MATCH JACKET STYLE
Condition: Improper/Lack of Maintenance
Due 3 January 2002
Resolved 3 January 2002
Navigation
Issued 12 January 2000
Resolved
RAISE STERN LIGHT ABOVE CANOPY
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Construction/Loadline
Issued 12 January 2000
Resolved
INSTALL BILGE ALARM IN ACCORDANCE WITH 46 CFR 182.530.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Lifesaving
Issued 19 June 1997
Resolved
INSTALL AN ADDITIONAL LIFEFLOAT. PASSENGERS AND CREW NOT TO EXCEED TWENTY FOUR UNTIL LIFEFLOAT INSTALLED.
Condition: Unknown
Due 17 July 1997
Resolved 20 June 1997
Documentation
Issued 19 June 1997
Resolved
RENEW EXPIRED DOCUMENTATION CERTIFICATE.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Documentation
Issued 19 June 1997
Resolved
PROVIDE EVIDENCE THAT A STABILITY TEST HAS BEEN CONDUCTED TO THE SATISFACTION OF THE COGNIZANT OCMI OR; CONDUCT A SATISFACTORY SIMPLIFIED STABILITY TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR IAW 46 CFRSUBCHAPTER "S".VESSEL CARGO LIMITED TO 1,000 LBS AT 1.5' VCG.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997