MAURY USCG vessel records Sign in
← All vessels

SEBAGO

SEBAGO is a 1991 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 1991, most recently in February 1998, along with 41 deficiencies.

Records from 1991 to 1998. Most recent: inspection, 4 February 1998.

Built
1991
Last inspected
4 February 1998
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBC9151
367986
Flag
UNITED STATES
367146210 (licence lapsed)
Maury page id
psix-367986

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (1991–1998)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.5 ft × 30.0 ft × 7.3 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREENE MARINE INC · YARMOUTH ME · built 1991
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 28 October 1991
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBC9151MMSI 367146210 · expired · compulsorily equipped · granted 19 October 2006, cancelled 4 March 2017
WAH6742MMSI not assigned · expired · compulsorily equipped · granted 9 December 1994, cancelled 29 January 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

4 February 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1107753
23 May 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106686
20 March 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098111
20 March 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106177
11 March 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099185
4 April 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1078867
27 March 1996 Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873179
30 January 1996 Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873177
21 June 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1190969
22 February 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851255
31 January 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829906
22 March 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1165314
9 March 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854530
14 January 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851044
21 September 1993 Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839618
29 April 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146421
3 February 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1137237
9 March 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 956726
31 January 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1266661
22 December 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1134937

Deficiency record · 41

Fire Fighting
Issued 11 March 1997 Resolved
Service both fixed halon systems.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Lifesaving
Issued 11 March 1997 Resolved
Re-stencil name of vessel on ring buoy.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Construction/Loadline
Issued 11 March 1997 Resolved
Properly wire bilge pumps using crimp type wire connectors.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Lifesaving
Issued 11 March 1997 Resolved
Re-stencil name of vessel and capacity on both buoyant apparatus.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Lifesaving
Issued 11 March 1997 Resolved
Properly make up painter and waterlight lines on both buoyant apparatus'.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Lifesaving
Issued 11 March 1997 Resolved
Renew retro reflective tape on PFD's.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Documentation
Issued 11 March 1997 Resolved
Renew FCC Radio Safety Cert.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Fire Fighting
Issued 11 March 1997 Resolved
Service one B-II fire extinguisher.
Condition: Unknown
Due 18 March 1997
Resolved 12 March 1997
Lifesaving
Issued 27 March 1996 Resolved
REPAIR SURFACE CRACKS ON ONE 18 PERSON BUOYANT APPARATUS USING APPROVED JIM-BUOY PATCH KIT.
Condition: Unknown
Due 4 April 1996
Resolved 5 April 1996
Lifesaving
Issued 27 March 1996 Resolved
RE-STENCIL VSL NAME AND CAPACITY ON BOTH BUOYANT APPARATUS.
Condition: Unknown
Due 4 April 1996
Resolved 5 April 1996
Lifesaving
Issued 21 June 1995 Resolved
CONDUCT UNDERWAY DRILLS.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 21 June 1995 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH DRUG TESTING REQUIREMENTS OF 46 CFR PART 15.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Engineering
Issued 21 June 1995 Resolved
REPLACE PORT FUEL TANK EMEEGENCY FUEL SHUTOFF VALVE.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Accommodation/Occupational Safety
Issued 21 June 1995 Resolved
MARK ACCESS OPENINGS THROUGH AFT SEAT WITH "FUEL SHUTOFF" - PORT AND STARBOARD SIDE.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Lifesaving
Issued 21 June 1995 Resolved
REPLACE MISSING WATERLIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 31 January 1995 Resolved
Remount B-II fire extinguisher on port side.
Condition: Unknown
Due 15 February 1995
Resolved 22 February 1995
Fire Fighting
Issued 31 January 1995 Resolved
Service B-I fire extinguisher at steering station and Halon systems in eachengineroom._x001C_ (Temporary replacement of halon with extra B-II extinguisher allowed due toavailibility of replacement)
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 31 January 1995 Resolved
Restencil lifejacket stowage areas.
Condition: Unknown
Due 15 February 1995
Resolved 22 February 1995
Documentation
Issued 31 January 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 February 1995
Resolved 22 February 1995
Lifesaving
Issued 31 January 1995 Resolved
Replace both weaklinks on lifefloats.
Condition: Unknown
Due 15 February 1995
Resolved 22 February 1995
Engineering
Issued 14 January 1994 Resolved
STENCIL FUEL TANK EMERGENCY SHUTOFF VALVES.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Construction/Loadline
Issued 14 January 1994 Resolved
PROVIDE BILGE PIPE SUCTION STRAINERS WITH AN AREA NOT LESS THAN 3 TIMES THAT OF PIPE.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Construction/Loadline
Issued 14 January 1994 Resolved
RESECURE FRONT DECK MOUNTING BOLTS.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Electrical
Issued 14 January 1994 Resolved
REPLACE BOTH BATTERY VENTS W/SUITABLE REINFORCED HOSE.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Accommodation/Occupational Safety
Issued 14 January 1994 Resolved
INSTALL OVERBOARD VALVES IN MSD DISCHARGE LINE. VALVES MUST BE LOCKABLE ORMAINTAINED IN A CLOSED POSITION NOT READILY OPENED. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Engineering
Issued 3 February 1993 Resolved
LABEL FUEL SHUTOFF VALVES.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Fire Fighting
Issued 3 February 1993 Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Construction/Loadline
Issued 3 February 1993 Resolved
SEAL ALL ENGINE ROOM BULKHEAD PENETRATIONS.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Documentation
Issued 3 February 1993 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Navigation
Issued 3 February 1993 Resolved
REPAIR AND PROVE OPERATION OF MASTHEAD LIGHT.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Documentation
Issued 3 February 1993 Resolved
PROVIDE DUPLICATE COPY OF FCC SAFETY RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Lifesaving
Issued 3 February 1993 Resolved
STOW PAINTERS FOR BUOYANT APPARATUS SO THEY WILL DEPLOY FREELY.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Lifesaving
Issued 31 January 1992 Resolved
PROVIDE WATERTIGHT CONTAINER FOR FLARES.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Electrical
Issued 31 January 1992 Resolved
REPLACE MACERATOR PUMP CIRCUIT BREAKERS WITH ONES RATED AT NOT GREATER THAN15 AMPS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Engineering
Issued 31 January 1992 Resolved
INSTALL FLAME SHIELDS ON RACOR FUEL FILTERS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Lifesaving
Issued 31 January 1992 Resolved
INSTALL WEAK LINK ON BUOYANT APPARATUS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Documentation
Issued 31 January 1992 Resolved
POST STABILITY LETTER, CERTIFICATES AND DOCUMENTS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Construction/Loadline
Issued 31 January 1992 Resolved
PROVIDE PORTABLE TRASH PUMP.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Engineering
Issued 31 January 1992 Resolved
INSTALL GUARDS OVER ROTATING PULLEYS ON ENGINE.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Construction/Loadline
Issued 31 January 1992 Resolved
INSTALL FIXED BILGE SYSTEM COMPLYING WITH 46 CFR PART 182.25.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Lifesaving
Issued 31 January 1992 Resolved
STENCIL CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.