Records from 1991 to 1998. Most recent: inspection, 4 February 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
4 February 1998
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1107753
23 May 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106686
20 March 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098111
20 March 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106177
11 March 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099185
4 April 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1078867
27 March 1996
Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873179
30 January 1996
Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873177
21 June 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1190969
22 February 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851255
31 January 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829906
22 March 1994
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1165314
9 March 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854530
14 January 1994
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851044
21 September 1993
Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839618
29 April 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146421
3 February 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1137237
9 March 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 956726
31 January 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1266661
22 December 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1134937
Fire Fighting
Issued 11 March 1997
Resolved
Service both fixed halon systems.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Lifesaving
Issued 11 March 1997
Resolved
Re-stencil name of vessel on ring buoy.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Construction/Loadline
Issued 11 March 1997
Resolved
Properly wire bilge pumps using crimp type wire connectors.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Lifesaving
Issued 11 March 1997
Resolved
Re-stencil name of vessel and capacity on both buoyant apparatus.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Lifesaving
Issued 11 March 1997
Resolved
Properly make up painter and waterlight lines on both buoyant apparatus'.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Lifesaving
Issued 11 March 1997
Resolved
Renew retro reflective tape on PFD's.
Condition: Unknown
Due 18 March 1997
Resolved 24 March 1997
Documentation
Issued 11 March 1997
Resolved
Renew FCC Radio Safety Cert.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Fire Fighting
Issued 11 March 1997
Resolved
Service one B-II fire extinguisher.
Condition: Unknown
Due 18 March 1997
Resolved 12 March 1997
Lifesaving
Issued 27 March 1996
Resolved
REPAIR SURFACE CRACKS ON ONE 18 PERSON BUOYANT APPARATUS USING APPROVED JIM-BUOY PATCH KIT.
Condition: Unknown
Due 4 April 1996
Resolved 5 April 1996
Lifesaving
Issued 27 March 1996
Resolved
RE-STENCIL VSL NAME AND CAPACITY ON BOTH BUOYANT APPARATUS.
Condition: Unknown
Due 4 April 1996
Resolved 5 April 1996
Lifesaving
Issued 21 June 1995
Resolved
CONDUCT UNDERWAY DRILLS.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 21 June 1995
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH DRUG TESTING REQUIREMENTS OF 46 CFR PART 15.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Engineering
Issued 21 June 1995
Resolved
REPLACE PORT FUEL TANK EMEEGENCY FUEL SHUTOFF VALVE.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Accommodation/Occupational Safety
Issued 21 June 1995
Resolved
MARK ACCESS OPENINGS THROUGH AFT SEAT WITH "FUEL SHUTOFF" - PORT AND STARBOARD SIDE.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Lifesaving
Issued 21 June 1995
Resolved
REPLACE MISSING WATERLIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Fire Fighting
Issued 31 January 1995
Resolved
Remount B-II fire extinguisher on port side.
Condition: Unknown
Due 15 February 1995
Resolved 22 February 1995
Fire Fighting
Issued 31 January 1995
Resolved
Service B-I fire extinguisher at steering station and Halon systems in eachengineroom._x001C_ (Temporary replacement of halon with extra B-II extinguisher allowed due toavailibility of replacement)
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 31 January 1995
Resolved
Restencil lifejacket stowage areas.
Condition: Unknown
Due 15 February 1995
Resolved 22 February 1995
Documentation
Issued 31 January 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 February 1995
Resolved 22 February 1995
Lifesaving
Issued 31 January 1995
Resolved
Replace both weaklinks on lifefloats.
Condition: Unknown
Due 15 February 1995
Resolved 22 February 1995
Engineering
Issued 14 January 1994
Resolved
STENCIL FUEL TANK EMERGENCY SHUTOFF VALVES.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Construction/Loadline
Issued 14 January 1994
Resolved
PROVIDE BILGE PIPE SUCTION STRAINERS WITH AN AREA NOT LESS THAN 3 TIMES THAT OF PIPE.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Construction/Loadline
Issued 14 January 1994
Resolved
RESECURE FRONT DECK MOUNTING BOLTS.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Electrical
Issued 14 January 1994
Resolved
REPLACE BOTH BATTERY VENTS W/SUITABLE REINFORCED HOSE.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Accommodation/Occupational Safety
Issued 14 January 1994
Resolved
INSTALL OVERBOARD VALVES IN MSD DISCHARGE LINE. VALVES MUST BE LOCKABLE ORMAINTAINED IN A CLOSED POSITION NOT READILY OPENED. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Engineering
Issued 3 February 1993
Resolved
LABEL FUEL SHUTOFF VALVES.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Fire Fighting
Issued 3 February 1993
Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Construction/Loadline
Issued 3 February 1993
Resolved
SEAL ALL ENGINE ROOM BULKHEAD PENETRATIONS.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Documentation
Issued 3 February 1993
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Navigation
Issued 3 February 1993
Resolved
REPAIR AND PROVE OPERATION OF MASTHEAD LIGHT.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Documentation
Issued 3 February 1993
Resolved
PROVIDE DUPLICATE COPY OF FCC SAFETY RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Lifesaving
Issued 3 February 1993
Resolved
STOW PAINTERS FOR BUOYANT APPARATUS SO THEY WILL DEPLOY FREELY.
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Lifesaving
Issued 31 January 1992
Resolved
PROVIDE WATERTIGHT CONTAINER FOR FLARES.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Electrical
Issued 31 January 1992
Resolved
REPLACE MACERATOR PUMP CIRCUIT BREAKERS WITH ONES RATED AT NOT GREATER THAN15 AMPS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Engineering
Issued 31 January 1992
Resolved
INSTALL FLAME SHIELDS ON RACOR FUEL FILTERS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Lifesaving
Issued 31 January 1992
Resolved
INSTALL WEAK LINK ON BUOYANT APPARATUS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Documentation
Issued 31 January 1992
Resolved
POST STABILITY LETTER, CERTIFICATES AND DOCUMENTS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Construction/Loadline
Issued 31 January 1992
Resolved
PROVIDE PORTABLE TRASH PUMP.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Engineering
Issued 31 January 1992
Resolved
INSTALL GUARDS OVER ROTATING PULLEYS ON ENGINE.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Construction/Loadline
Issued 31 January 1992
Resolved
INSTALL FIXED BILGE SYSTEM COMPLYING WITH 46 CFR PART 182.25.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Lifesaving
Issued 31 January 1992
Resolved
STENCIL CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993