Records from 1991 to 2010. Most recent: inspection, 3 February 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
3 February 2010
COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3674787
24 July 2009
Re-Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3544618
30 June 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3252459
18 July 2007
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3019890
27 October 2006
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2809116
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806610
21 February 2006
Damage Survey · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2588986
28 June 2005
Examination of Repairs · Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2406602
14 April 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2334000
13 September 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2194478
15 August 2003
Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1877072
28 August 2002
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1667999
29 July 2002
COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1653743
9 August 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469363
6 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771689
3 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 199779
14 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449357
27 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770628
15 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 199778
13 August 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418579
15 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809985
9 September 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470738
26 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 169650
10 September 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386088
1 July 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383599
11 September 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448800
3 November 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880722
20 October 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380338
1 June 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414460
15 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212745
15 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213312
15 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1149455
2 November 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382860
16 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 367271
9 November 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436818
21 May 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354366
10 November 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397837
19 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 26769
10 February 1992
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955137
7 February 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 153668
22 November 1991
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 945274
Stability › Watertight Integrity › General
Issued 24 July 2009
Resolved
Main deck cabin windows must be replaced prior to offshore operations. 46 CFR 177.1020
Action required: 705 - Other - as specified
Due 14 August 2009
Resolved 14 August 2009
Resolution: Deficiency corrected to the satifaction of attending CG Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 30 June 2008
Resolved
Show proper operation of port inboard bridge shutdown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2008
Operations/Management › Pollution › Discharge of Cargo Residue
Issued 30 June 2008
Resolved
Remove excess oily water in engine room bilges.
Action required: 705 - Other - as specified
Resolved 30 June 2008
Engineering › Generator (propulsion-electric) › Winding
Issued 30 June 2008
Resolved
Clean excess oil on both generators and clean the windings.
Action required: 705 - Other - as specified
Resolved 30 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 June 2008
Resolved
Provide solid rubber mat in generator space for distribution panel
Action required: 705 - Other - as specified
Resolved 30 June 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 30 June 2008
Resolved
Place emergency lights to show emergency exits in engine room and generator space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 30 June 2008
Resolved
Place emergency lights to show emergency exits in engine room and generator space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2008
Lifesaving › Lifefloat › Serviceable
Issued 13 September 2004
Resolved
Three lifefloats not serviceable. Renew with approved type.
Condition: Improper/Lack of Maintenance
Due 13 September 2004
Resolved 14 September 2004
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2004
Resolved
Six cracks on stern and rudder stop damaged. Reweld as needed.
Condition: Improper/Lack of Maintenance
Due 13 September 2004
Resolved 13 September 2004
Stability › Watertight Integrity › General
Issued 13 September 2004
Resolved
WTD to steering room does not dog all the way closed. Adjust door as needed and show proper operation.
Condition: Improper/Lack of Maintenance
Due 13 September 2004
Resolved 13 September 2004
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 13 September 2004
Resolved
Range hood filter needs renewed. Clogged with grease.
Condition: Improper/Lack of Maintenance
Due 13 September 2004
Resolved 14 September 2004
Engineering › Fuel Oil Service System
Issued 15 August 2003
Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON ALL HOSES AS DISCUSSED. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 15 September 2003
Deck/Cargo › Holds/Tanks
Issued 15 August 2003
Resolved
PROVIDE AND INSTALL SIGHT GLASS ON STARBOARD TANK. LEGACY COMPONENT DESC: Liquid Level Gauging
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 15 September 2003
Lifesaving › Buoyant Apparatus
Issued 15 August 2003
Resolved
PROVIDE AND INSTALL ONE PADDLE ON LIFE FLOAT PRIOR TO SAILING. LEGACY COMPONENT DESC: LIFE FLOAT PADDLES
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2003
Resolved 15 September 2003
Documentation › Certificates/Documents
Issued 15 August 2003
Resolved
PROVIDE BRIDGE-TO-BRIDGE RADIO CERTIFICATE. LEGACY COMPONENT DESC: BRIDGE TO BRIDGE RADIO CERTIFICATE
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 15 September 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 15 August 2003
Resolved
PROVIDE AND INSTALL SAFETY RAILS ON STERN PRIOR TO SAILING. LEGACY COMPONENT DESC: Deck Rail
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2003
Resolved 15 September 2003
Engineering › Fuel Oil Service System
Issued 15 August 2003
Resolved
RENEW ALL FUEL HOSES ON MAIN ENGINES AND GENERATORS NOT MEETING J-1942 SPECIFICATIONS AS PER 46CFR 182.720. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 15 September 2003
Lifesaving › Lifeboat Equipment › Boat Hook
Issued 15 August 2003
Resolved
PROVIDE AND INSTALL BOAT HOOKS PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2003
Resolved 15 September 2003
Engineering › Bilge Water Management System
Issued 29 July 2002
Resolved
Install clamp on forepeak bilge suction line so that vibration doesn't make joint connection fail.
LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 21 August 2002
Engineering › Pressure Vessel
Issued 29 July 2002
Resolved
Install relief valve on hot water heater that is 100 psi or less or make hot water heater ready for inspection as pressure vessel.
LEGACY COMPONENT DESC: Relief Valve
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 21 August 2002
Electrical › Electric Supply System (service)
Issued 29 July 2002
Resolved
Install metal wire clamps where wires come off of guages in eng. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 August 2002
Resolved 21 August 2002