MAURY USCG vessel records
← All vessels

VERNON C. BAIN

Built
1991
Last inspected
16 October 2025
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 16 October 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 6 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

368307
Flag
UNITED STATES
Tonnage
47326 - Convention (Subpart B), Gross Ton 14197 - Convention (Subpart B), Net Ton 609 - Dead Weight, Ton 17376 - Displacement, Ton
Maury page id
psix-368307
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

16 October 2025 Deficiency Check · Load Line/Change of Employment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8254189
7 July 2009 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3526471
18 March 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2026974
1 March 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2021148
6 September 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182036
27 July 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1180207
8 June 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1176102
29 April 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860618
1 February 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853424
13 January 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1162029
21 October 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834706
21 October 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132910
9 July 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158996
20 May 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1144141
19 April 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147382
31 March 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837922
18 March 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150722
26 February 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834955
4 February 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829745
29 January 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135186
12 January 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1138049
4 December 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 828728
3 September 1992 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933807
10 July 1992 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944426
1 May 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942749
8 April 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 947181
3 January 1992 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 949744

Deficiency record · 54

Accommodation/Occupational Safety
Issued 29 April 1994 Resolved
REPLACE ALL BURNT OUT LIGHT BULBS FOR ALL MCC PANELS (PANELS IN FAN ROOMS FOR VENTILATION).
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Accommodation/Occupational Safety
Issued 29 April 1994 Resolved
REPLACE LIGHT GUARD IN FREEZER 01-44-3.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Construction/Loadline
Issued 29 April 1994 Resolved
ADJUST WATERTIGHT DOOR #2-9-5 BY WT ROOM.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Accommodation/Occupational Safety
Issued 29 April 1994 Resolved
REPLACE GLOBE IN VEG LOCKER 01-46-1.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Accommodation/Occupational Safety
Issued 29 April 1994 Resolved
REPAIR STEAM/HOT WATER LEAKS IN ALL FAN ROOMS.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Lifesaving
Issued 29 April 1994 Resolved
REPAIR WATERTIGHT DOOR OPERATION ALARM IN THE ENGINEROOM.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Electrical
Issued 29 April 1994 Resolved
MAKE PROPER REPAIRS TO LEAK IN FLEX COUPLINGS ON #1 & 2 S/S GENERATORS J/W RETURN.
Condition: Unknown
Due 31 July 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 13 January 1994 Resolved
PROVE PROPER OPERATION OF BOTH FUEL OIL TANK REMOTE SHUTDOWN IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Lifesaving
Issued 13 January 1994 Resolved
PROVE PROPER OPERATION OF SOUND POWERED PHONE (2JV) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Electrical
Issued 13 January 1994 Resolved
INSTALL PROPER ELECTRICAL COVERS ON ONE OUTLET AND ONE JUNCTION BOX IN CLINIC RECEPTION DESK AREA (NURSES STATION) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Fire Fighting
Issued 13 January 1994 Resolved
PROVE PROPER OPERATION OF FIRE SCREEN DOORS #1-25-2 AND 1-13-2 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Lifesaving
Issued 13 January 1994 Resolved
MAKE #2 AIR RECEIVER, CHILL WATER TANK, AND #1,#2 & #3 CHEMICAL FEED WATER TANKS READY FOR INTERNAL EXAM OR HYDROSTATIC TEST IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Engineering
Issued 21 October 1993 Resolved
CONDUCTED HYDROSTATIC TEST OF THREE AUXILIARY BOILERS TO ONE AND ONE QUARTER MAWP AT NEXT INSPECTION FOR CERTIFICATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Engineering
Issued 9 July 1993 Resolved
PROVIDE PROTECTIVE DEVICES AS PER 46 CFR 54.15-5 FOR ALL THREE BOILER CHEMICAL FEED TANKS. ALL THREE ARE STAMPED AS CLASS II PRESSURE VESSELS ANDCONTAIN HAZARDOUS MATERIALS. THE ABOVE REQUIREMENT TO BE COMPLETED BY 31AUG93.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Lifesaving
Issued 9 July 1993 Resolved
COMPLETE ATTACHED WORKLISTS (01-09 AND E1-E8) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR FOR COMPLETION OF CERTIFICATE OF INSPECTION BUT NO LATER THAN 27JUL93.
Condition: Unknown
Due 13 September 1993
Resolved 13 September 1993
Fire Fighting
Issued 9 July 1993 Resolved
VERIFY FIRE CONTROL PLANS AS TO THE EQUIPMENT REQUIRED BY 46 CFR AND THE EQUIPMENT ONBOARD. ITEM #2 TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR BY 15SEP93.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Engineering
Issued 31 March 1993 Resolved
PROVE PROPER OPERATION OF #1 AUXILIARY BOILER HAND RELEASING GEAR FOR RELIEF VALVE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Engineering
Issued 31 March 1993 Resolved
INSTALL AND PROVE PROPER OPERATION OF THE #1 AUXILIARY BOILER FIRE EYE MICROPROCESSOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Fire Fighting
Issued 31 March 1993 Resolved
REPLACE NON-APPROVED FIRE NOZZLE AT FIRESTATION NO. 16 WITH A USCG APPROVEDFIRE NOZZLE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Electrical
Issued 31 March 1993 Resolved
PROVE PROPER OPERATION OF EMERGENCY DIESEL GENERATOR LOW LUBE OIL PRESSURE SHUTDOWN AND OVERSPEED TRIP. SYSTEM TO BE CAPABLE OF BEING TESTED AT EACH QUARTERLY INSPECTION._x001C_ _x001C_
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Electrical
Issued 31 March 1993 Resolved
PROVE PROPER OPERATION OF #1 & #2 SSDE LOW LUBE OIL PRESSURE SHUTDOWN. SYSTEM TO BE CAPABLE OF BEING TESTED AT EACH QUARTERLY INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Fire Fighting
Issued 31 March 1993 Resolved
PROVE PROPER OPERATION OF #1 FIRE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Electrical
Issued 31 March 1993 Resolved
PROVE PROPER OPERATION OF #1 & #2 SSDGS IN PARALLEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Accommodation/Occupational Safety
Issued 18 March 1993 Resolved
PROVE PROPER OPERATION OF #2 ELEVATOR NO LATER THAN 18 SEPTEMBER 1993.
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Electrical
Issued 18 March 1993 Resolved
SUBMIT PLANS TO THE MARINE SAFETY CENTER FOR APPROVAL OF THE PROPOSED MODIFICATIONS TO THE GENERATOR COOLING SYSTEMS. SUBMIT A WRITTEN LETTER TOOCMI NEW YORK UPON COMPLETION OF THE SAME TO BE COMPLETED PRIOR TO 18JUN93.
Condition: Unknown
Due 1 May 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 12 January 1993 Resolved
PROVE PROPER OPERATION NO. 1 AUX BOILER INCLUDING ALL ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Fire Fighting
Issued 12 January 1993 Resolved
REATTACH ALL BROKEN PIPE SUPPORTS FOR FIREMAIN SHORE TIE.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Unknown
Issued 12 January 1993 Resolved
PROVE PROPER OPERATION OF PORTABLE DRINKING WATER PURIFICATION SYSTEM TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Unknown
Issued 12 January 1993 Resolved
PROVE PROPER OPERATION OF SOUND POWERED PHONE IN CENTRAL CONTROL STATION.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Accommodation/Occupational Safety
Issued 12 January 1993 Resolved
PROVE PROPER OPERATION OF ALL ELEVATORS.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Construction/Loadline
Issued 12 January 1993 Resolved
PERMANENTLY AFFIX HANDLES TO CONTROLS OF WATERTIGHT DOOR #2.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Fire Fighting
Issued 12 January 1993 Resolved
PROVE PROPER OPERATION OF ALL VENTILATION SYSTEM DAMPERS.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Electrical
Issued 12 January 1993 Resolved
MAKE NECESSARY REPAIRS TO CRACK IN DISCHARGE PIPING OF #2 SERVICE AIR COMPRESSOR.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Engineering
Issued 12 January 1993 Resolved
REPLACE GAGE GLASSES FOR NO.1 AND NO.2 AUX BOILERS.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Construction/Loadline
Issued 12 January 1993 Resolved
PROVE PROPER OPERATION OF BILGE ALARM / SENSOR FOR FRAMES 31 TO 37.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Electrical
Issued 12 January 1993 Resolved
REPLACE ALL MISSING ELECTRICAL CIRCUIT BREAKER PANEL COVERS.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Electrical
Issued 12 January 1993 Resolved
PROVIDE OCMI NEW YORK WITH A WRITTEN PROPOSAL TO CORRECT PROBLEM WITH OVERHEATING OF MAIN GENERATORS DURING SUMMER MONTHS.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 12 January 1993 Resolved
MAKE NECESSARY REPAIRS TO DISCHARGE PIPING OF NO. 1 AUX BOILER FEED WATER PUMP.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Accommodation/Occupational Safety
Issued 10 July 1992 Resolved
PROVIDE HAND LIFTING DEVICES FOR RELEIF VALVES OF THREE PRESSURE VESSELS INENGINEROOM. PRESSURE VESSEL SERIAL NUMBERS: 2368-1, 2368-2, AND 2368-3.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Lifesaving
Issued 10 July 1992 Resolved
BRING ALL VERTICAL LADDERS GREATER THAN 20FT LONG INTO COMPLIANCE WITH ANSISTANDARD 14.3(1974)(LADDER SAFETY DEVICE) OR FIT WITH A CAGE.
Condition: Unknown
Due 9 December 1992
Resolved 9 December 1992
Fire Fighting
Issued 10 July 1992 Resolved
PROPERLY MOUNT AND LABEL THE FOUR PORTABLE EXTINGUISHERS IN THE MACHINERY CONTROL ROOM AND THE TWO PORTABLE EXTINGUISHERS IN THE BOILER ROOM.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Fire Fighting
Issued 10 July 1992 Resolved
PROVE PROPER OPERATION OF TIME DELAY ON THE PAINT LOCKER FIXED CO2 EXTINGUISHING SYSTEM.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Lifesaving
Issued 10 July 1992 Resolved
PROVIDE APPROVED FIRE & SAFETY PLAN
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Accommodation/Occupational Safety
Issued 10 July 1992 Resolved
PROVE PROPER OPERATION OF ELEVATOR CALL ALARM IN ELEVATOR #4
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Accommodation/Occupational Safety
Issued 10 July 1992 Resolved
PROVE PROPER OPERATION OF MANUAL DOOR RELEASE MECHANISM IN ELEVATOR #4.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Lifesaving
Issued 10 July 1992 Resolved
PROVIDE COPY OF APPROVED EVACUATION PLAN.
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Accommodation/Occupational Safety
Issued 1 May 1992 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS IN THE 3C UPPER & LOWER LEVELS, PROVE PROPER OPERATION OF THE #4 & #3 ELEVATORS.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 1 May 1992 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, CONDUCT IN THE PRESENCE OF COAST GUARDINSPECTORS, A FIRE DRILL (TO BE COORDINATED WITH NYFD RESPONDING) & AND EVACUATION DRILL. BOTH DRILLS SHALL BE CONDUCTED USING THE BAIN'S STAFF PERSONNEL.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 3 January 1992 Resolved
PROVIDE THE FOLLOWING EMERGENCY PLANS AND DRILLS: 1. FIRE CONTROL AND SAFETY PLAN REVISED TO MEET NVIC 10-91 Pr 15.a.(1). 2. WATCH QUARTER AND STATION BILL (NVIC Pr 15.a.(2) 3. EVACUATION PLAN 4. PROPOSED PLAN FOR MEETING REQUIRED DRILLS (NVIC 10-91 Pr 15.b.)
Condition: Unknown
Due 3 January 1992
Resolved 3 January 1992
Accommodation/Occupational Safety
Issued 3 January 1992 Resolved
PROVIDE THE NUMBER OF INMATES, STAFF,VISITORS, AND OTHERS AS REQUIRED BY NVIC 10-91 PARA. 3.A.
Condition: Unknown
Due 3 January 1992
Resolved 3 January 1992
Construction/Loadline
Issued 3 January 1992 Resolved
MAKE OPERATIONAL THE EMERGENCY HAND PUMP MODE ON SLIDING WTD NO. 1 AT FRAME31 TANKTOP IN MAIN MACHINERY SPACE.
Condition: Unknown
Due 3 January 1992
Resolved 28 January 1992
Fire Fighting
Issued 3 January 1992 Resolved
PROVIDE LABEL PLATES FOR SPRINKLER PULL RING HANDLES IN CONTRO; ROOMS 1-8-4AND 03-35-0.
Condition: Unknown
Due 6 January 1992
Resolved 28 January 1992
Fire Fighting
Issued 3 January 1992 Resolved
STINCIL BULKHEAD WITH F.E. # AT FIRE STATION 68 LOCATED AT 04-15-0.
Condition: Unknown
Due 6 January 1992
Resolved 28 January 1992
Lifesaving
Issued 3 January 1992 Resolved
PROVIDE FOR INCLUSION IN THE FIRE CONTROL AND SAFETY PLAN, THE MANNER IN WHICH THE KEYS ARE MADE ACCESSIBLE IN CASE OF EMERGENCY (NVIC 10-91 PARA 9.f)
Condition: Unknown
Due 3 January 1992
Resolved 3 January 1992

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.