MAURY USCG vessel records Sign in
← All vessels

RYU YOH

RYU YOH is a 1991 freight ship. The Coast Guard has recorded 14 inspections since 1991, most recently in February 2010, along with 3 deficiencies and 1 operational control.

Records from 1991 to 2010. Most recent: inspection, 24 February 2010.

Built
1991
Last inspected
24 February 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8921444 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
368320
Flag
PANAMA
—
Maury page id
psix-368320

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (1991–2010)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it19442 - Convention (Subpart B), Net Ton
53943 - Displacement, Ton
44733 - Dead Weight, Ton
38844 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

24 February 2010 MARPOL Annex VI Survey · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3684947
2 January 2002 Passenger/Freight Vessel Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1474782
13 March 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 275748
16 January 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 424554
2 February 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 514518
20 November 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 410093
23 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 402881
24 June 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 392244
25 January 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 387143
21 June 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 379639
30 August 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 369944
30 August 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 861179
18 November 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 354494
21 October 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 346713

Deficiency record · 3

Construction/Loadline
Issued 20 November 1997 Resolved
Replace broken valve inside forward middle ballast tank. Valve is used for opening and closing discharge/suction for ballast tank. Divers couldnt access valve to fix it, tank was being pumped out while inspectors were on board. Correct to the satisfaction of Class Society.
Condition: Unknown
Due 2 February 1998
Resolved 2 February 1998
Lifesaving
Issued 25 January 1996 Resolved
RENEW/REPAIR/REPLACE DETERIORATED LIFERING BUOYS. PROVIDE TWELVE RING BUOYSON STATION IN A SERVICABLE CONDITION AND AVAILABLE FOR IMMEDIATE USE._x001C_ SOLAS 74 AMENDED III/19.2
Condition: Unknown
Due 25 January 1996
Resolved 30 January 1996
Fire Fighting
Issued 30 August 1994 Resolved
During the exam, three fire hoses were found which were ruptured and in need of replacement.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.