MAURY USCG vessel records Sign in
← All vessels

OLYMPOS

OLYMPOS is a 2001 freight ship. The Coast Guard has recorded 23 inspections since 2001, most recently in March 2018, along with 5 deficiencies and 1 operational control.

Records from 2001 to 2018. Most recent: operational control imposed, 14 March 2018.

Built
2001
Last inspected
14 March 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9224714 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-36836

Inspections, by type

…with no type recorded6
Years with a record 14 calendar years (2001–2018)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it75256 - Dead Weight, Ton
86719 - Displacement, Ton
40605 - Regulatory (Subpart C or D), Gross Ton
40605 - Convention (Subpart B), Gross Ton
24814 - Regulatory (Subpart C or D), Net Ton
24814 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

14 March 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6372063
21 January 2018 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6337507
19 January 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6344444
18 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6289303
24 May 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6137486
7 April 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5843411
28 August 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4942439
11 June 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4334494
28 April 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3463141
28 April 2009 PII Safety Exam · ISPS II Exam · In-Service Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3463152
23 March 2009 ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3434114
19 May 2008 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3210784
14 May 2008 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3207052
5 May 2008 ISPS I Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3194132
4 May 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3199206
7 June 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2954304
5 July 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2703849
1 June 2005 PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2375786
21 December 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2263123
27 October 2003 Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1936654
15 July 2002 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1646592
11 July 2002 Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1646393
18 October 2001 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 294819

Deficiency record · 5

Electrical › Electric Generation Source (emergency) › Panelboard
Issued 21 January 2018 Resolved
1499 OTHER (PROP & AUX MACHINERY) THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. EMERGENCY GENERATOR HERTZ METER ON EMERGENCY GENERATOR SWITCHBOARD IS INOPERATIVE. 74 SOLAS(CONS 04)I/11(a). 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2018
Resolved 24 January 2018
Resolution: Wiring connection issue resolved. Accepted NKK class report attesting to proper operation of emergency generator control panel.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 21 January 2018 Resolved
0715 DETECTION INDICATING UNITS SHALL DENOTE THE SECTION IN WHICH A DETECTOR OR MANUALLY OPERATED CALL POINT HAS OPERATED. THE ZONING INDICATORS ON THE FIXED FIRE FIGHTING CONTROL PANEL ON THE BRIDGE IS INOPERATIVE. 74 SOLAS(CONS 01)II-2/13.1.6. 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2018
Resolved 24 January 2018
Resolution: Accepted NKK report attesting to proper operation of fire control panel. Connection between main panel and repeater panel cables cleaned and re-connected.
Engineering › Steam System (auxiliary) › Piping
Issued 24 May 2017 Resolved
1499 OTHER (PROP & AUX. MACHINERY): EVERY STEAM PIPE AND EVERY FITTING CONNECTED THERETO THROUGH WHICH STEAM MAY PASS SHALL BE SO DESIGNED, CONSTRUCTED AND INSTALLED AS TO WITHSTAND THE MAXIMUM WORKING STRESSES TO WHICH IT MAY BE SUBJECTED. STEAM LINE FOR FUEL OIL STORAGE TANK HAS MULTIPLE LEAKS. 74SOLAS(01)II-1/33.1 50AC
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 17 October 2017
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Engineering › Feedwater/Condensate Water System › Piping
Issued 24 May 2017 Resolved
1499 OTHER (PROP. & AUX. MACHINERY) THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHAL BE MAINTIANED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THERE IS 01 PATCH ON COOLING WATER SUPPLY LINE FOR STEAM CONDENSOR. 74SOLAS(14)I/11(a) 50AC
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 17 October 2017
Resolution: PSC NOLA recieved a class report from NKK satisfying the requirement.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 11 June 2012 Resolved
Vessel is required to have a valid International Load Line Certificate to proceed to sea on a international voyage. Vessel does not have a valid International Load Line Certificate on board for the intended voyage. ILLC 66 Article 3, 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2012
Resolution: Master provided a copy of the ILLC.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.