MAURY USCG vessel records Sign in
← All vessels

RISING SUN

RISING SUN is a 1987 tank ship. The Coast Guard has recorded 28 inspections since 1991, most recently in February 2010, along with 13 deficiencies — 4 with no resolution recorded — and 3 operational controls.

Records from 1991 to 2010. Most recent: inspection, 26 February 2010.

Built
1987
Last inspected
26 February 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8607816 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
368394
Flag
MARSHALL ISLANDS
—
Maury page id
psix-368394

Inspections, by type

…with no type recorded13
…past their stated due date1
Years with a record 10 calendar years (1991–2010)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11369 - Regulatory (Subpart C or D), Net Ton
11369 - Convention (Subpart B), Net Ton
38864 - Dead Weight, Ton
48338 - Displacement, Ton
23930 - Regulatory (Subpart C or D), Gross Ton
23930 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

26 February 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3686636
20 February 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3682923
18 February 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3682012
3 February 2010 PII Safety Exam · COC-CHEM Renew · ISPS I Exam · COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3674410
2 February 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3671961
15 July 2006 COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2710555
16 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2515440
15 October 2005 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2515084
14 February 2005 PII Safety Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2290675
22 July 2004 PII Safety Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2141211
18 June 2004 COC-TVE Annual · ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2102917
22 January 2004 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1990261
15 August 2003 Security Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1877023
28 June 2003 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1829321
12 February 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1745037
12 February 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1747817
6 February 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1740577
30 March 2002 Tank Vessel Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1599537
16 February 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 287129
16 February 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1373328
15 November 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 434697
12 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 515755
21 July 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 728389
16 July 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 430795
16 July 1999 Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1101315
9 August 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 419144
8 August 1998 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386318
20 October 1991 Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 962963

Deficiency record · 13

Construction/Loadline › Structures › Door
Issued 3 February 2010 No resolution recorded
1270; Means for securing doors/weather tight shall consist of gaskets and clamping devices and shall be permanently attached to the bulkhead. Forward peak store door has a wasted gasket, compromising it's water tightness; ICLL 66 CH-II REG 12.1; 70c.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Structures › Deck Plating
Issued 3 February 2010 No resolution recorded
0999; Satisfactory means shall be provided for the protection of the crew in getting to and from all parts used in the necessary work of the ship. Platform 2m forward and starboard of the deck water seal is wasted; ICLL 66 CH-II REG 25.4; 70a.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electric Generation Source (emergency) › Generator
Issued 3 February 2010 Resolved
1499; Emergency generator set arranged to be automatically started shall be equipped with starting devices approved by the admin. with a stored energy capability of at least 3 consecutive starts. A second source of energy shall be provided for additional three starts. Battery start is inoperable, only one means of starting the generator available; SOLAS 2004 CH-II-I REG 44.2; 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2010
Resolution: New batteries were installed and the PSCO witnessed the Emergency Generator start both manually and via the hydraulic secondary actuator. Test sat.
Lifesaving › Inflatable Liferafts › Lamp (outside)
Issued 3 February 2010 No resolution recorded
0945; During preparation and launching, survival craft, launching appliance and the area of water into which it is launched shall be adequately illuminated. Forward life raft light is inoperable; SOLAS 1997 CH-III REG 15.7; 17a
Action required: 705 - Other - as specified
Due 4 March 2010 — due date passed with no resolution recorded
Fire Fighting › Nozzles › Condition
Issued 3 February 2010 Resolved
0720; Fire extinguishing appliance shall be kept in good order and available for immediate use; Gaskets on foam nozzle starboard side, and on fire hose in emergency escape chute wasted; SOLAS 1997 CH-II-2 REG 21; 17c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 February 2010
Resolution: Crew renewed gaskets on both the Stbd foam nozzle and the fire hose in the emergency escape chute.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 3 February 2010 Resolved
1830; Machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they intended and shall be so installed and protected. Cargo pump #1 will not start or operate from either the CCR or ECR; SOLAS 2004 CH-II-1; 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2010
Resolution: PSCO witnessed the #1 cargo pump working from both the engine control room and the cargo control room. #1 pump was started and stopped from both locations. Ships electrician found a loose connection in the wiring during troubleshooting. Test sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 3 February 2010 Resolved
1999; Suitable marked decontamination showers and eyewash shall be available on deck in convenient locations. The showers and eyewash shall be operable in all ambient temperatures. Eyewash station did not supply water and was inoperable; SOLAS 2004 CH-II-2 REG 1.6.6; IBC CODE CH-14.3.4; 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2010
Resolution: All four eyewash stations on deck were tested satisfactorily. A combination of ice and salt caused the initial failure. All nozzles were disassembled and cleaned.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 3 February 2010 No resolution recorded
1899- PSCO discovered IGS to not consistently function as designed or IAW the vsls IGS manual. Specifically, psi switch for low h20 alarm at the deck seal would not reset. Scrubber pump alarm was inoperable. o2 analyzer not calibrated shore side annually IAW ships IGS manual. Class to attest to prop op of IGS and all alarms. Vsl is prohibited from carrying cargo that req inert atmosphere.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Steering Gear System › Rudder
Issued 21 January 2004 Resolved
Rudder repeater in steering appears to have loose connection inside the repeater. All visible connections of linkage are tight. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2004
Resolved 22 July 2004
Resolution: Recieved class report.
Lifesaving › Lifeboat Equipment
Issued 28 June 2003 Resolved
Found 5 food rations in Port LB and 10 in the stbd LB with vacuum seal broken and interior food compromised. LEGACY COMPONENT DESC: Food Ration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2003
Resolution: Received fax for 15 food rations from ship.
Pollution Prevention/Response › Prevention Equipment
Issued 30 March 2002 Resolved
REPAIR SEWAGE TREATMENT PLANT BY INSTALLING PROPER CL TREATMENT TUBES IN TOP OF UNIT AS ORIGINALLY DESIGNED. INSTALLATION TO BE VERIFIEDAS INTENDED BY AN ATTENDING CLASS SURVEYOR AND A WRITTEN CLASS REPORT SHALL BE FAXED TO THE U.S COAST GUARD CAPTAIN OF THE PORT OF INTENDED NEXT U.S. PORT. LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2002
Resolution: Received class report.
Fire Fighting
Issued 16 July 1999 Resolved
Remove holdbacks from all fire screen doors prior to return to US waters after sailing foriegn.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Navigation
Issued 16 July 1999 Resolved
Provide an autopilot alarm in accordance with 33 CFR 157.440.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999

Ownership record