MAURY USCG vessel records Sign in
← All vessels

FV COHO.COM

FV COHO.COM is a 1978 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2002, most recently in May 2019, along with 14 deficiencies.

Records from 2002 to 2019. Most recent: inspection, 17 May 2019.

Built
1978
Last inspected
17 May 2019
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-36878

Inspections, by type

Years with a record 9 calendar years (2002–2019)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)32.8 ft × 12.3 ft × 6.8 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERTRAM YACHT INC · MIAMI, FL, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portKENOSHA, WI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

17 May 2019 Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6705582
15 May 2018 Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6452626
12 October 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6020944
17 March 2016 Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5835460
10 June 2014 Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4885026
13 April 2008 Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3186868
12 April 2008 Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3186399
20 June 2007 Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2970105
29 September 2004 Uninspected Passenger Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2209111
23 June 2003 Uninspected Passenger Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1760357
19 September 2002 Uninspected Passenger Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1680282

Deficiency record · 14

Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 12 April 2008 Resolved
NUMBER REQUIRED NOT ONBOARD
Due 17 May 2008
Resolved 13 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2008 Resolved
STERN LIGHT INOPERABLE
Due 17 May 2008
Resolved 13 April 2008
Documentation › Certificates/Documents
Issued 23 June 2003 Resolved
Certificate of Documentation expired, renew. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Resolved 5 August 2003
Resolution: Vessel has a current Certificate of Documentation
Documentation › Markings/Placards
Issued 23 June 2003 Resolved
Permanently affix "NO." to vessel. LEGACY COMPONENT DESC: Official Number (US)
Action required: 705 - Other - as specified
Resolved 5 August 2003
Resolution: "No." has been permanently affixed in before the offical documentation number.
Engineering › Bilge Water Management System
Issued 23 June 2003 Resolved
Replace bilge pump switch. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 August 2003
Resolution: new float switch has been installed to bilge pump
Lifesaving › Lifebuoys
Issued 23 June 2003 Resolved
Replace worn out ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 August 2003
Resolution: ring bouy has been replaced
Engineering › Gasoline Engine (propulsion)
Issued 23 June 2003 Resolved
Clean flame arrester, port engine LEGACY COMPONENT DESC: Backfire Flame Control
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 August 2003
Resolution: flame arrester has been cleaned
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 September 2002 Resolved
Provide valid Certificate of documentation, I.A.W. 46 CFR 67.15
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2002
Resolved 19 September 2002
Documentation › Logs/Records › Drug Test Records
Issued 19 September 2002 Resolved
Provide company drug testing program or proof of enrolement in a Coast Guard approved drug testing consortium I.A.W. 46 CFR 16.
Action required: 705 - Other - as specified
Resolved 12 October 2016
Resolution: Deleted stagnant deficiency.
Documentation › Markings/Placards › Official Number (US)
Issued 19 September 2002 Resolved
Permanantely mark Doucmentaion number on interior of vessels hull I.A.W. 46 CFR 67.121.
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 12 October 2016
Resolution: Deleted; stagnant deficiency.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 19 September 2002 Resolved
Renew two adult PFD lights, I.A.W. 46 CFR 25.25-13.
Action required: 705 - Other - as specified
Resolved 12 October 2016
Resolution: Deleted; stagnant deficiency.
Navigation › Collision/Grounding Avoidance
Issued 19 September 2002 Resolved
Repair and prove proper operation of stern light. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 19 September 2002
Resolved 19 September 2002
Resolution: Corrected prior to end of examination.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 September 2002 Resolved
Secure starting batteries I.A.W. 33 CFR 183.420.
Action required: 705 - Other - as specified
Resolved 12 October 2016
Resolution: Deleted; stagnant deficiency.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 September 2002 Resolved
Install static grounding straps for fuel tank(s) I.A.W. 33 CFR 183.572.
Action required: 705 - Other - as specified
Resolved 12 October 2016
Resolution: Deleted stagnant deficiency

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.