MAURY USCG vessel records Sign in
← All vessels

SEA SPIRIT

SEA SPIRIT is a 1991 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1991, most recently in May 2009, along with 47 deficiencies and 1 operational control.

Records from 1991 to 2009. Most recent: inspection, 13 May 2009.

Built
1991
Last inspected
13 May 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8802868 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
368919
Flag
BELIZE
—
Maury page id
psix-368919

Inspections, by type

…with no type recorded26
Years with a record 12 calendar years (1991–2009)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it650 - Dead Weight, Ton
3260 - Displacement, Ton
1263 - Convention (Subpart B), Net Ton
4200 - Regulatory (Subpart C or D), Gross Ton
4200 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 55

13 May 2009 COC-CVE Annual · ISPS II Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3474346
29 December 2008 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3385721
23 July 2008 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3277655
25 May 2008 ISPS III Exam · Deficiency Check · COC-CVE Annual · NPV Safety Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3208725
22 May 2008 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3212082
26 March 2008 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3171995
7 January 2008 COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3125607
25 July 2007 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3007955
14 May 2007 COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2930305
13 June 2006 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2679059
16 May 2006 COC-CVE Annual · ISPS III Exam
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2650998
3 March 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2595359
11 December 2005 COC-CVE Quarterly
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2549577
11 December 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2551222
21 July 2005 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2435121
19 July 2005 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2432178
15 July 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2426607
10 June 2005 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2389132
14 May 2005 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2357760
2 May 2005 COC-CVE Annual
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2347381
30 July 2004 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2157915
29 June 2004 ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2115587
15 June 2004 PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2141092
21 May 2004 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2074335
14 May 2004 MARPOL Annex I Examination · COC-CVE Annual · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2071584
21 August 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1900963
15 August 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1879883
15 August 2003 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1879960
30 July 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1863211
1 July 2003 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1832524
21 May 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1798599
21 May 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1804775
15 May 2003 Certificate of Compliance · Deficiency Check · MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1792812
29 October 2002 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1697807
25 October 2002 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1696279
6 August 2002 Passenger/Freight Vessel Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1657655
17 July 2002 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1648023
19 June 2002 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1698520
29 May 2002 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1698489
17 May 2002 MARPOL Annex I Examination · Certificate of Compliance · Passenger/Freight Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1625846
10 March 2002 Security Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1492808
4 September 2001 Quarterly Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1467327
12 June 2001 Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 181757
12 June 2001 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1065795
7 June 2001 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 290554
7 June 2001 Control Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1461416
5 June 2001 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 480191
27 March 2001 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1384720
17 December 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 674985
29 November 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 363165
15 November 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 363139
2 September 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1271032
6 February 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 348626
4 January 1992 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251361
7 December 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 347955

Deficiency record · 47

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 May 2009 Resolved
FSD 3025 does not close properly. Door must be removed in order to be realigned. Vessel to realign door in next port without passengers. Vessel to implement live watch at door until door closes automatically. SOLAS (2004 cons ed) II-2 Reg 9
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 22 May 2009
Resolution: Vessel made satisfactoy repairs to FSD.
Lifesaving › Launching Appliances › Davit
Issued 25 May 2008 Resolved
Vessel unable to demonstrate use of liferaft davit. Vessel to demonstrate satisfactory use of liferaft davit w/ training raft suitable for davit launch or use existing compliment by 25Nov2008.
Due 25 November 2008
Resolved 29 December 2008
Resolution: Item corrected.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 22 May 2008 Resolved
Sopep missing contact information for the COTP Zone of Western Alaska.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 22 May 2008
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 22 May 2008 Resolved
Exposed/dead end wiring in the battery room needs to be removed.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 May 2008
Resolution: Examined/cleared.
Lifesaving › Lifeboat Equipment › Signalling Mirror
Issued 22 May 2008 Resolved
Signalling mirror missing from lifeboat #2. Mirror put on boat prior to Coast Guard leaving.
Condition: Unknown
Due 22 May 2008
Resolved 22 May 2008
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 22 May 2008 Resolved
There is no simple line diagram of the steering system posted in the steering compartment.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 25 May 2008
Resolution: Examined/cleared.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 January 2008 Resolved
Crew mess entrance fire door and deck II lobby to crew entrance fire doors do not close properly. Repair to the satisfaction of class. SOLAS 2001 II-2/ Reg 30
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 February 2008
Resolved 26 March 2008
Resolution: Doors verified to be repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 January 2008 Resolved
Fluorescent lighting fixtures in club lounge on top sill of port and starboard windows are missing protective cover. Repair to the satisfaction of class. SOLAS 2004 II-1 / Reg 45.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 February 2008
Resolved 26 March 2008
Resolution: Lighting Fixtures have protective covers.
Lifesaving › Inflatable Liferafts › Inflation Characteristics
Issued 7 January 2008 Resolved
Crew was unable to inflate training life raft. Repair prior to next U.S. port after sailing foreign. SOLAS 2004 III/Reg 19.4.3.
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 26 March 2008
Resolution: Vessel agent supplied air tank for inflating liferaft. Verified crew could inflate liferaft.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 December 2005 Resolved
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2005
Resolved 11 December 2005
Resolution: detectors installed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 December 2005 Resolved
doors do not fully close and latch
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2005
Resolved 12 December 2005
Resolution: doors adjusted to perform properly
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 11 December 2005 Resolved
new installation required further maintenance to gain complete and proper installation
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2005
Resolved 12 December 2005
Resolution: finished proper instalation.
Fire Fighting › Automatic Sprinkler System › Power Sources
Issued 11 December 2005 Resolved
system connection to the Emergency gen was incomplete, providing an open circuit, thus the sprinkler system would not function from the e-gen source of power.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2005
Resolved 12 December 2005
Resolution: electrician found fault and repaired same, closing circuit and ensuring proper operation.
Fire Fighting › Means of Escape › Blocked
Issued 11 December 2005 Resolved
escape route blocked with parts general debri
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2005
Resolved 12 December 2005
Resolution: escape route cleared
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 December 2005 Resolved
burned out bulb.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2005
Resolved 12 December 2005
Resolution: replaced bulb ops sat.
Engineering › Bilge Water Management System › Pump
Issued 11 December 2005 Resolved
bilge suction did not have handle
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2005
Resolved 12 December 2005
Resolution: handle installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 December 2005 Resolved
WTD in #3 stabilizer room non=operation from bridge controll.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2005
Resolved 12 December 2005
Resolution: repaired to provide required service.
Engineering › Bilge Water Management System › Pump
Issued 2 May 2005 Resolved
No bilge pump installed/tested on emergency bus at time of inspection. SOLAS (92 CONS) CH II-1 21.2, 42.2.1.8
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Resolution: Was installed and tested satisfactorily.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 2 May 2005 Resolved
Several fire doors did not close upon activation of control switch during fire drill: Deck 1 (1003, 1027); Deck 2 (2042, 2008, 2030) SOLAS (92 CONS) CH II-1 30.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 May 2005 Resolved
During abanson ship drill, crew did not adequately demonstrate checking all cabins or ability to direct passengers as required. SOLAS (04 CONS) CH III 19.2, 30
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Resolution: Drill was conducted a second time with satisfactory results.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 May 2005 Resolved
Poor stowage related to yard period blocked escape scuttles (in laundry & engineering spaces). SOLAS (92 CONS) CH II-2 28
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Fire Fighting › Structural - Main Vertical Zones › General
Issued 2 May 2005 Resolved
Repair dire doors activation of control switch during fire drill: Deck 2 (2003, 2041) SOLAS (92 CONS) CH II-1/ 30.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 3 May 2005
Resolution: ABS class surveyor [name withheld] attended vessel and witnessed satisfactory operation of fire doors.
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 14 May 2004 Resolved
Fuel Oil transfer pipelines not hydrostaticly tested
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2004
Resolved 23 July 2004
Resolution: Corrected during def check in Dutch Harbor
Stability › Watertight Integrity
Issued 15 May 2003 Resolved
Watertight door #4 has a leaking seal at the top, and the audible alarm does not indicate when the door is closing.
Action required: 705 - Other - as specified
Due 15 June 2003
Resolved 26 May 2003
Fire Fighting › Miscellaneous Items
Issued 15 May 2003 Resolved
Waste receptacles in several cabins are not constructed of non-combustible materials per SOLAS 74 (amended) II-2/18.5. LEGACY COMPONENT DESC: Waste Receptacles
Action required: 705 - Other - as specified
Due 15 June 2003
Resolved 15 August 2003
Resolution: In place 61 new metal receptacles.
Communications › Alarms/Indicators › Fire Alarm
Issued 15 May 2003 Resolved
The smoke detector in the beverage storeroom 5-S does not give a correct alarm location on the bridge alarm panel.
Due 15 June 2003
Resolved 15 May 2003
Resolution: Corrected on site.
Documentation › Certificates/Documents
Issued 6 August 2002 Resolved
Provide Tender Safety Equipment Certificate issued by the vessel's classification society.
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 15 May 2003
Resolution: Sighted certificates issued by ABS. Noted that vessel manning was not specified on the certificates.
Deck/Cargo › Ballast
Issued 17 May 2002 Resolved
Noted soft patches on ballast piping. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2002
Resolved 20 May 2002
Resolution: Repairs made to ballast piping to satisfaction of attending class surveyor.
Pollution Prevention/Response › Prevention Equipment
Issued 17 May 2002 Resolved
Leaky cement patches on port and starboard marine sanitation holding tanks. LEGACY COMPONENT DESC: Sewage System Tank
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2002
Resolved 20 May 2002
Resolution: Repairs made to MSD holding tanks to satisfaction of attending class surveyor.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 17 May 2002 Resolved
Lagging on A/C water pipes damaged.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2002
Resolved 20 May 2002
Resolution: Repairs made to lagging on A/C water pipes to satisfaction of attending class surveyor.
Fire Fighting
Issued 7 June 2001 Resolved
LABEL FIRE DAMPERS # 15 & 27.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
PROVIDE LAUNDRY DUCT CLEANOUT IN AC#2.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
REMOVE CARDBOARD VENT DEFLECTORS IN E/R & LAUNDRY DUCTS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Lifesaving
Issued 7 June 2001 Resolved
REGISTER EPIRB W/ NOAA OR FLAG STATE
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
IMPLEMENT MAINTENANCE PLAN FOR ALL VENT DUCTS AND CLOSURES, PARTICULARLY E/R & LAUNDRY.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
REMOVE BLACK WATER FROM STBD BILGE OF MSD ROOM
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Electrical
Issued 7 June 2001 Resolved
PROVIDE PERMANENT BATTERY CHARGING SYSTEM.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Lifesaving
Issued 7 June 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
REMOVE CHEMICALS FROM PORT MSD ROOM BILGE.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
REMOVE EQUIPMENT STORED IN FRONT OF LAUNDRY POWER PANEL.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
MAKE WTD # 1 OPERATIONAL FROM BRIDGE CONTROL.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Navigation
Issued 15 November 1993 Resolved
COAST PILOT NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Navigation
Issued 15 November 1993 Resolved
NO LIGHT LIST ON BOARD FOR AREA TRANSISTED.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Documentation
Issued 15 November 1993 Resolved
IOPP CERTIFICATE SECTION 2.6.2 INCORRECT FOR VESSEL.
Condition: Unknown
Due 17 December 1993
Resolved 17 December 1993
Navigation
Issued 15 November 1993 Resolved
PRE-ARRIVAL TESTS NOT LOGGED.
Condition: Unknown
Due 15 November 1993
Resolved 15 December 1993
Documentation
Issued 7 December 1991 Resolved
The vessels fuel capacity is 200 metric tons and the vessels Oil transfer Procedures were incomplete in that(1)procedures for emptying containment,(2) duties by title for each officer,(3) procedures for toppingoff tanks,(4) means of comms,(5)procedures for securing valves were missing
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 7 December 1991 Resolved
The vessel failed to have "oil discharge prohibited" placards posted in machinery and fuel manifold spaces.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.