Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named BLUE RIDGE
BLUE RIDGE is a 1979 freight ship. The Coast Guard has recorded 8 inspections since 1991, most recently in September 2004, along with 73 deficiencies and 4 operational controls.
Records from 1991 to 2004. Most recent: operational control imposed, 7 September 2004.
- Built
- 1979
- Last inspected
- 7 September 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 73 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7818418 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3JD5
368934
Flag
ROMANIA
—
Maury page id
psix-368934
Inspections, by type
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9540 - Dead Weight, Ton
3885 - Regulatory (Subpart C or D), Net Ton
11747 - Convention (Subpart B), Gross Ton
11747 - Regulatory (Subpart C or D), Gross Ton
3885 - Regulatory (Subpart C or D), Net Ton
11747 - Convention (Subpart B), Gross Ton
11747 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
7 September 2004
NPV Safety Exam · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2189658
11 December 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 449664
4 September 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 407552
5 August 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 393891
9 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 389622
22 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 716125
9 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 386463
10 November 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 439337
Deficiency record · 73
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 7 September 2004
Resolved
Emergency generator switchboard missing rear access plates. Make repairs to the satisfaction of class prior to departure from the Port of Houston.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2004
Resolved
Light fixtures throughout the ship are missing light bulbs, globes, and explosion proof parts. Make repairs to the satisfaction of class prior to departure from the Port of Houston.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 7 September 2004
Resolved
Shaft seal packing is leaking excessively compromising general seaworthiness. Make repairs to the satisfaction of class prior to departure from the Port of Houston.
Fire Fighting
Issued 4 September 1997
Resolved
PROVIDE CLASS REPORT AND OPERATION MANUAL FOR FIXED EXTINGUISHING SYSTEM.
Construction/Loadline
Issued 4 September 1997
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATING EQUIPMENT AND PROVIDE CLASSREPORT.
Electrical
Issued 4 September 1997
Resolved
PROVIDE PROPER COVERS AND BULBS FOR LIGHTING FIXTURES THROUGHOUT SHIP.
Engineering
Issued 4 September 1997
Resolved
RENEW SOFT PATCH ON MAIN COOLING LINE TO AFT MAIN ENGINE.
Fire Fighting
Issued 4 September 1997
Resolved
PROVE PROPER OPERATION OF ALL FIRE DOORS AND PROVIDE CLASS REPORT.
Navigation
Issued 5 August 1996
Resolved
RENEW/REPAIR INOPERABLE GYRO COMPASS. PROVIDE SERVICE REPORT ATTESTING TO PROPER OPERATION OF GYRO COMPASS. _x001C_ 33 C.F.R. 164.35(d)
Electrical
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FRESH WATER COOLING LINE TO THE TURBO CHARGER FOR #1 MAIN GENERATOR.
Electrical
Issued 9 January 1996
Resolved
REPAIR DISCONNECTED REMOTE OPERATING REACH ROD TO VALVE LOCATED PORT SIDE_x001C_ OUTBOARD OF #1 MAIN GENERATOR.
Electrical
Issued 9 January 1996
Resolved
REPAIR DISCONNECTED REMOTE OPERATING REACH ROD TO VALVE LOCATED STARBOARD_x001C_ SIDE OUTBOARD #4 MAIN GENERATOR.
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
REMOVE SPARE PARTS LAYING ON THE DECK BEHIND THE MAIN SWITCH BOARD IN THE_x001C_ ENGINE CONTROL ROOM.
Electrical
Issued 9 January 1996
Resolved
RENEW/REPAIR MISSING LIGHT FIXTURE LOCATED BEHIND THE MAIN SWITCHBOARD IN THE ENGINE CONTROL ROOM.
Lifesaving
Issued 9 January 1996
Resolved
PROVIDE AND POST MUSTER LIST AND EMERGENCY INSTRUCTIONS IN ENGINE ROOM IN ACONSPICUOUS PLACE.LIST AND INSTRUCTIONS SHALL BE IN THE LANGUAGES UNDERSTOOD BY THE CREW._x001C_ SOLAS 74 (AMENDED) III/8
Documentation
Issued 9 January 1996
Resolved
PROVIDE AND POST "DISCHARGE OF OIL PROHIBITED" PLACARD AT THE BILGE _x001C_ CONTROL PANEL AND CONSPICUOUS PLACES IN THE ENGINE ROOM.PLACARD SHALL BE_x001C_ IN THE LANGUAGES UNDERSTOOD BY THE CREW. _x001C_ 33 C.F.R. 155.450
Engineering
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FRESH WATER SUPPLY COOLING PIPE TO MAIN DIESEL ENGINE INJECTOR COOLING SUPPLY LOCATED IN THE COMPRESSOR ROOM.
Deck/Cargo
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER COOLING SUPPLY PIPE TO #2 AIR_x001C_ COMPRESSOR.
Deck/Cargo
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER COOLING SUPPLY PIPE TO #3 AIR_x001C_ COMPRESSOR.
Deck/Cargo
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED CONDENSATE WATER LINE IN WAY OF #1 AIR_x001C_ COMPRESSOR.
Lifesaving
Issued 9 January 1996
Resolved
RENEW/REMOVE OIL SOAKED INSULATION TO THE MAIN DIESEL ENGINE SCAVANGING AIRDUCT.
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FROM AREA SURROUNDING SEPERATORS.
Electrical
Issued 9 January 1996
Resolved
ISOLATE AND CLEAR FULL PHASE GROUND ON 400 VOLT ELECTRICAL SUPPLY PANEL K1
Fire Fighting
Issued 9 January 1996
Resolved
PROVIDE DUEL PURPOSE FIRE NOZZLES TO EACH FIRE STATION LOCATED IN THE_x001C_ MACHINERY SPACES._x001C_ SOLAS 60 II/65(c)(IV)
Engineering
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED BOILER SUPPLY PIPE LOCATED AFT IN ENGINE_x001C_ ROOM ON DECK IMMEDIATELY ABOVE THE SHAFT IN WAY OF #48 TANK.
Fire Fighting
Issued 9 January 1996
Resolved
PROVIDE THE PROPER PORTABLE FIRE EXTINGUISHER TO EMPTY FIRE STATION LOCATEDIN THE ENGINE ROOM LOWER LEVEL STARBOARD SIDE._x001C_ SOLAS 74 (AMENDED) II-2/21
Engineering
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER SUPPLY PIPING LOCATED LOWER LEVELENGINE ROOM STARBOARD SIDE OVERHEAD IN WAY OF SALT WATER PUMPS.
Engineering
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED STEAM SUPPLY LINE LOCATED LOWER LEVEL ENGINEROOM FORWARD STARBOARD CORNER NEAR THE OVERHEAD.
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
INVESTIGATE AND REPAIR FRESH WATER LEAK LOCATED AFT ENGINE ROOM ON PLATFORMABOVE THE SHAFT PORTSIDE.
Lifesaving
Issued 9 January 1996
Resolved
RENEW/REPAIR AND PROVE SATISFACTORY OPERATION OF THE STARBOARD LIFE BOAT_x001C_ ENGINE._x001C_ SOLAS 60 III/(a)(i)
Lifesaving
Issued 9 January 1996
Resolved
MAKE PERMANENT REPAIRS TO CRACKED ACCESS HATCHES FOR STARBOARD LIFEBOAT._x001C_ SOLAS 74 (AMENDED) III/19.2
Navigation
Issued 9 January 1996
Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR PROPER OPERATION OF THE SHIPS GYRO COMPASS AND ALL REPEATORS._x001C_ 33 C.F.R. 164.35(d)(e)
Lifesaving
Issued 9 January 1996
Resolved
PROVIDE TWO TWENTY PERSON LIFERAFTS IN ACCORDANCE WITH SHIPS SAFETY EQUIPMENT CERTIFICATE, ON STATION, AND PROPERLY SECURED WITH HYDROSTATIC RELEASE UNITS._x001C_ SOLAS 60 III/35(a)(i)
Lifesaving
Issued 9 January 1996
Resolved
PROVIDE ONE LIFERAFT ON OR NEAR THE BOW IN ACCORDANCE WITH SOLAS 74 (AMENDED) III/26.3.2
Fire Fighting
Issued 9 January 1996
Resolved
CONDUCT A SATISFACTORY TEST OF THE SMOKE DETECTION SYSTEM TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR._x001C_ SOLAS 74 (AMENDED) II-2/40.3
Engineering
Issued 9 January 1996
Resolved
REPAIR/RENEW DEFECTIVE 15PPM INDICATOR TO OILY WATER SEPERATOR. SEE 33CFR155.370_x001C_
Lifesaving
Issued 9 January 1996
Resolved
RENEW ALL DEFECTIVE RING LIFE BOUYS.PROVIDE EIGHT RING LIFE BOUYS ON STATION IN ACCORDANCE WITH THE SHIPS SAFETY EQUIPMENT CERTIFICATE. ENSURE_x001C_ RING LIFE BOUYS ARE AVAILABLE FOR IMMEDIATE USE._x001C_ SOLAS 74 (AMENDED) III/19.2
Fire Fighting
Issued 9 January 1996
Resolved
REPLACE MISSING SMOKE DETECTOR IN STEERING GEAR ROOM._x001C_ SOLAS 60 II/61(a)
Electrical
Issued 9 January 1996
Resolved
SECURE BATTERIES IN BATTERY ROOMS LOCATED AFT OF PILOT HOUSE.BATTERIES ARE TO BE SECURED SO THAT THEY WILL NOT SHIFT WITHIN THE BATTERY BOXES.
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING TO FIRE HYDRANT STBD SIDE_x001C_ BRIDGE WING._x001C_ SOLAS 74 (AMENDED) II-2/21
Engineering
Issued 9 January 1996
Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FROM MAIN GENERATOR FUEL OIL SEPERATOR CONTAINMENT.
Fire Fighting
Issued 9 January 1996
Resolved
CONDUCT SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THEATTENDING U.S. COAST GUARD MARINE INSPECTOR._x001C_ SOLAS 74 (AMENDED) III/18.3.1
Fire Fighting
Issued 9 January 1996
Resolved
RENEW ALL DEFECTIVE FIRE HOSES THROUGHOUT VESSEL.NOTED SEVERAL OF THOSE CHECKED WERE HOLED.ALL FIRE HOSES THROUGHOUT THE VESSEL SHALL BE RENEWED AND/OR PRESSURE TESTED IN THE PRESENCE OF THE ATTENDING MARINE INSPECTOR TOENSURE THEY ARE AVAILABLE FOR IMMEDIATE USE. SOLAS 74 (AMENDED) II-2/21
Construction/Loadline
Issued 9 January 1996
Resolved
RENEW/REPAIR WEATHERTIGHT COVER FOR WELDING ELECTRODES LOCATED PORT SIDE ONBOAT DECK._x001C_ SOLAS 60 II/27.(a)(i)(1)
Fire Fighting
Issued 9 January 1996
Resolved
RENEW/REPAIR INOPERATIVE FIRE HYDRANT VALVE LOCATED PORT SIDE ON BOAT DECK. SOLAS 74 (AMENDED) II-2/21
Lifesaving
Issued 9 January 1996
Resolved
RENEW/REPAIR BROKEN KEEL GRAB RAILS TO PORT LIFEBOAT._x001C_ SOLAS 60 III/11(a)(xvi)
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
RENEW MISSING DOG BOLT TO NATURAL VENTILATION CLOSURE LOCATED AFT ON THE_x001C_ PORT BOAT DECK._x001C_ SOLAS 60 II/47(a)
Fire Fighting
Issued 9 January 1996
Resolved
RENEW/REPAIR INOPERATIVE FIRE HYDRANT VALVE LOCATED AFT ON THE BOAT DECK._x001C_ SOLAS 74 (AMENDED) II-2/21
Electrical
Issued 9 January 1996
Resolved
RENEW MISSING DOG BOLTS TO THE SHORE TIE ELECTRICAL BOX LOCATED AFT ON THE_x001C_BOAT DECK. _x001C_ SOLAS 60 II/27(a)(i)(1)
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
RENEW DETERIORATED NATURAL VENTILATION DUCTS/DAMPERS LOCATED STARBOARD SIDEON THE BOAT DECK._x001C_ SOLAS 60 II/47(a)
Electrical
Issued 9 January 1996
Resolved
REPLACE MISSING/BROKEN LIGHT BULBS THROUGHOUT THE VESSEL.ALL SPACES ARE TO_x001C_BE ADEQUATELY LIGHTED TO ENSURE PERSONNEL SAFETY.PROVIDE COVERS FOR LIGHT_x001C_ FIXTURES.
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED NATURAL VENTILATION DUCTS LOCATED ON THE _x001C_ FANTAIL._x001C_ SOLAS 60 II/47(a)
Fire Fighting
Issued 9 January 1996
Resolved
RENEW/REPAIR INOPERATIVE FIRE HYDRANT VALVE LOCATED PORT SIDE ON THE MAIN_x001C_ DECK FWD OF THE AFT DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 9 January 1996
Resolved
RENEW/REPAIR INOPERATIVE FIRE HYDRANT VALVE LOCATED STARBOARD SIDE ON THE_x001C_ MAIN DECK FWD OF THE AFT DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 9 January 1996
Resolved
RENEW/REPAIR INOPERATIVE FIRE MAIN ISOLATION VALVE LOCATED PORTSIDE IN WAY_x001C_OF #3 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Electrical
Issued 9 January 1996
Resolved
RENEW/MAKE PERMANENT REPAIRS TO THE EMERGENCY GENERATOR COOLING LINE LOCATED BELOW THE COOLING FAN PORT SIDE._x001C_
Electrical
Issued 9 January 1996
Resolved
REPLACE MISSING HOSE CLAMPS ON THE EMERGENCY GENERATOR COOLING LINES._x001C_
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
REMOVE EXCESS OIL ON THE DECK IN HATCH COVER PUMP ROOM LOCATED FORWARD OF_x001C_ #2 HOLD.
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING TO FIRE HYDRANT LOCATED ON THE MAIN DECK PORT SIDE IN WAY OF #1 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Deck/Cargo
Issued 9 January 1996
Resolved
PROPERLY SECURE LOOSE PRESSURE BOTTLES STORED IN THE #1 DECK HOUSE.
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING TO FIRE HYDRANT LOCATED ON THE MAIN DECK PORT SIDE FWD OF #1 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGNAL DETERIORATED FIREMAIN PIPING TO FWD PAINT LOCKER SPRINKLERSYSTEM._x001C_ SOLAS 74 (AMENDED) II-2/21
Lifesaving
Issued 9 January 1996
Resolved
REMOVE GASOLINE CURRENTLY STORED IN FWD PAINT LOCKER AND STOW IN AN APPROPRIATE LOCATION.
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING TO FIRE HYDRANT LOCATED ON THE MAIN DECK STARBOARD SIDE IN WAY OF #2 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING TO FIRE HYDRANT LOCATED ON THE MAIN DECK STARBOARD SIDE IN WAY OF #2 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING LOCATED ON THE MAIN DECK STARBOARD SIDE IN WAY OF #2 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING LOCATED ON THE MAIN DECK STARBOARD SIDE AFT OF #2 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING LOCATED ON THE MAIN DECK STARBOARD SIDE FWD OF AFT DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 9 January 1996
Resolved
RENEW/REPAIR INOPERABLE FIREMAIN ISOLATION VALVE LOCATED ON THE MAIN DECK STARBOARD SIDE IN WAY OF #3 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Deck/Cargo
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER COOLING SUPPLY LINE TO #2 DOMESTIC REEFER COOLER UNIT,LOCATED ON THE MAIN DECK INSIDE COMPARTMENT 171
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
RENEW/REPAIR LEAKING TYPE III MSD PUMP. REMOVE RAW SEWAGE FROM THE DECK AROUND HOLDING TANK.
Accommodation/Occupational Safety
Issued 9 January 1996
Resolved
REMOVE EXCESS FUEL OIL/LUBE OIL AND RESIDUE FROM CONTAINMENTS IN BOILER ROOM.
Electrical
Issued 9 January 1996
Resolved
RENEW AS ORIGINAL DETERIORATED LUBE OIL COOLER PIPE TO #4 GENERATOR. _x001C_