Records from 2016 to 2025. Most recent: inspection, 26 June 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2025
Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Drawings are not required to be submitted for repairs or replacements in kind. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken.
Vessel notified SEC Mobile that they have swapped engines and shafts. The new engines do not appear to be replacement in kind; therefore you must request a replacement in kind determination and if not in-kind: submit plan review to verify the installation meets current laws and regulations.
Submissions should include drawings, sketches, or written specifications to include vessel's machinery arrangement, specification sheets for the main diesel engines and shafts, and any additional modifications to the vessel to include exhaust, piping, electrical, etc.
Once approved, request attendance from a marine inspector to validate installation and satisfactory operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: Vessels new engine/shaft installation was approved. See narrative for details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2024
Resolved
PROPULSION MACHINERY SHALL BE SUITABLE IN TYPE AND DESIGN FOR PROPULSION REQUIREMENTS OF THE HULL OF WHICH IT IS INSTALLED AND CAPABLE OF OPERATING AT CONSTANT MARINE LOAD. VESSEL STARBOARD SHAFT WAS OBSERVED TO HAVE EXCESSIVE SHAKING/SWAYING, LIKELY DUE TO A WORN OUT BEARING.
46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2025
Resolution: This deficiency is being cleared and replaced by the cg-835 issued on 16JUL2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2024
Resolved
A VESSEL MUST BE PROVIDED WITH BILGE PUMPS IN ACCORDANCE WITH TABLE 182.520(a). VESSEL'S BILGE PUMP IN THE AFT STEERING COMPARTMENT FAILED TO OPERATE. BILGE PUMP IN ENGINE ROOM WAS UNABLE TO BE TESTED DUE TO EXCESSIVE OIL AND DEBRIS IN THE BILGE.
46 CFR 182.520(a)(e)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2024
Resolution: Bilge pump tested satisfactorily. Verified audible/visual alarm at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2024
Resolved
ON A VESSEL OF AT LEAST 26 FEET IN LENGTH, A VISUAL AND AUDIBLE ALARM MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE HIGH WATER LEVEL. VESSEL'S HIGH WATER ALARM IN THE AFT STEERING COMPARTMENT FAILED TO OPERATE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2024
Resolution: Bilge pump tested satisfactorily. Verified audible/visual alarm at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2024
Resolved
SHUTOFF VALVES INSTALLED SO AS TO CLOSE AGAINST THE FUEL FLOW SHALL BE FITTED IN THE FUEL SUPPLY LINES, ONE AT THE TANK CONNECTION, AND ONE AT THE ENGINE. ONE OF THE SHUTOFF VALVES LOCATED AT THE TANK FAILED TO OPERATE.
46 CFR 182.20-40 (b)(3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2024
Resolution: Valve was replaced with new handle. Opened and closed valve satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 November 2024
Resolved
AT EACH INSPECTION FOR CERTIFICATION AND AT EVERY OTHER VESSEL INSPECTION THE BILGES AND OTHER SPACES MAY BE EXAMINED TO SEE THAT THERE IS NO EXCESSIVE ACCUMULATION OF OIL, TRASH, DEBRIS. VESSEL WAS FOUND TO HAVE EXCESSIVE OIL AND DEBRIS IN THE ENGINE ROOM BILGE.
46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2024
Resolution: Vessel sent in sat photos of clean bilges.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Vessel provided proof of passing drug test for their deckhand.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Vessel provided proof of deckhand's enrollment in random testing program.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Vessel provided newly purchased alcohol testing strips.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 November 2024
Resolved
ALL VESSELS MUST HAVE NAVIGATION LIGHTS THAT ARE IN
COMPLIANCE WITH THE APPLICABLE SECTIONS OF THE INLAND
NAVIGATION RULES. VESSEL'S STERN LIGHT WAS INOPERATIVE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Stern light was replaced with new LED light. Verified operation of light satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 7 November 2024
Resolved
EACH VESSEL THAT OPERATES BEYOND THREE MILES FROM THE COASTLINE MUST HAVE ON BOARD AN EPIRB INSTALLED TO AUTOMATICALLY FLOAT FREE AND ACTIVATE. VESSEL'S HYDROSTATIC RELEASE WAS EXPIRED.
46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Verified installation on new hydrostatic release, not expired.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 November 2024
Resolved
THE NUMBER OF PERSONS CAPACITY MUST BE MARKED OR PAINTED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH LIFE FLOAT. VESSEL'S LIFE FLOATS DID NOT HAVE THE PERSONS CAPACITY MARKED OR PAINTED.
46 CFR 185.604(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Verified persons capacity marked on each lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 November 2024
Resolved
AT LEAST ONE RING LIFE BUOY MUST BE FITTED WITH A LIFELINE. THE LIFELINE ATTACHED TO THE VESSEL'S LIFEBUOY NEAR THE PILOT HOUSE WAS FOUND TO BE DETERIORATING.
46 CFR 180.70(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Lifeline on buoy replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 November 2024
Resolved
AN ADULT LIFEJACKET MUST BE PROVIDED FOR EACH PERSON CARRIED ON BOARD A VESSEL. VESSEL IS REDUCED TO CARRYING 39 PASSENGERS UNTIL A SUFFICIENT AMOUNT OF PFDS CAN BE PROVIDED FOR THE TOTAL PERSONS ON BOARD PER THE VESSEL'S COI.
46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Verified adequate quantity of serviceable lifejackets per the vessel's COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 November 2024
Resolved
CABLES ENTERING BOXES OR FITTINGS SHALL BE PROTECTED FROM ABRASION. GENERATOR'S MAIN POWER CABLES WERE NOT PROVIDED WITH PROPER STUFFING TUBES.
46 CFR 183.10-20 (f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Verified that generator cable's were provided with proper stuffing tubes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2024
Resolved
FLEXIBLE NONMETALLIC HOSE MAY BE USED IN LUBE OIL, FUEL OIL, AND FLUID POWER SYSTEMS, SUBJECT TO THE FOLLOWING REQUIREMENTS: FLEXIBLE HOSE MUST BE FABRICATED WITH AN INNER TUBE AND A COVER OF SYNTHETIC RUBBER REINFORCED WITH WIRE BRAID. GENERATOR FUEL HOSE WAS FOUND TO HAVE SEVERAL CUTS ALONG WITH RUSTED INNER WIRE BRAIDING AND MUST BE REPLACED. (NEW FLEXIBLE HOSE MUST MEET SAEJ-1942 OR USCG A1, A2, B1, OR B2 FLEXIBLE HOSE)
46 CFR 182.720(e)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Verified new fuel hose meeting applicable standards.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 7 November 2024
Resolved
AT EACH INSPECTION FOR CERTIFICATION AND AT EVERY OTHER VESSEL INSPECTION, QUARTERS, TOILET AND WASHING SPACES, AND SIMILAR SPACES MAY BE EXAMINED TO DETERMINE THAT THEY ARE SERVICEABLE AND IN SANITARY CONDITION. VESSEL'S SEWAGE HOLDING TANK WAS FOUND TO HAVE AN OPENING AROUND THE PIPING ALLOWING GASES TO ESCAPE ALONG WITH LEAKS IN THE PIPING FROM THE TOILETS TO THE TANK.
46 CFR 176.25-45(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Verified repair of piping to vessel's sewage holding tank from toilet.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2024
Resolved
Vessel lapsed on getting annual inspection during inspection window, 3 months before or after each anniversary date. Schedule and sucessfully complete annual inspection.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2024
Resolved 7 November 2024
Resolution: VESSEL HAD COI INSPECTION CONDUCTED ON 07NOV24.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 August 2024
Resolved
EACH OPENING IN AN EXPOSED WEATHERDECK MUST HAVE A MEANS FOR CLOSING IT WEATHERTIGHT. SCUTTLES LEADING INTO THE AFT STEERING SPACE AND FUEL TANK COMPARTMENTS WERE FOUND TO BE NOT WEATHERTIGHT.
46 CFR 171.122(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 3 December 2024
Resolution: Both scuttles were observed to have renewed weatherstripping and the closing devices functioned satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2023
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J–1942 or be specifically approved by the Commandant. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Fuel hose on starboard main engine needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2023
Resolved 25 May 2023
Resolution: Received picture of replaced fuel hose.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 May 2023
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Cover on port fresh water tank must be permanently affixed and sealed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2023
Resolved 15 May 2023
Resolution: Received photograph of tank with cover installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2022
Resolved
Missing rotating machinery guards on engines
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 15 June 2022
Resolution: Received photos of sat guards, see docs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 April 2021
Resolved
VESSELS MUST COMPLETE A DRYDOCK EVERY TWO YEARS TO MAINTAIN A CURRENT COI. OUTCAST WAS REQUIRED TO COMPLETE A DRYDOCK INSPECTION ON OR PRIOR TO 30APR21. VESSEL DID NOT UNDERGO A DRYDOCK INSPECTION AND SHALL NOT OPERATE UNTIL AN INSPECTION IS COMPLETED TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2021
Resolution: Vessel completed drydock on 5/20/21. See activity #7206789 for details.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2020
Resolved
no repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a).
Action required: 705 - Other - as specified
Resolved 20 May 2021
Resolution: Vessel completed drydock 20MAY21, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 May 2019
Resolved
Provide updated Navigation Charts, Tide tables, light list, and Coast Pilot for operating area.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 21 May 2019
Resolution: Provided proof of correction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2019
Resolved
Ammonia Inhalants expired in first aid kit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 21 May 2019
Resolution: Provided proof of correction.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 May 2019
Resolved
Bulkhead cable runs need to be vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 21 May 2019
Resolution: Provided proof of correction.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 30 May 2017
Resolved
Minor leak at port engine exhaust cooling T fitting. IAW 46cfr182.425
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 20 June 2017
Resolution: Exhaust leak was inspected satisfactorily.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 30 May 2017
Resolved
FCC safety cert expired this past March 2017. IAW 46cfr184.502
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 20 June 2017
Resolution: New safety certificate was provided with experation date 31MAY22.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 30 May 2017
Resolved
Update light list for 2017. IAW 46cfr184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 20 June 2017
Resolution: Current light list was provided for inspection.
Communications › Public Address System › Loudspeaker
Issued 30 May 2017
Resolved
Repair PA speaker in lower berthing area, no sound when used. IAW 46cfr184.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 20 June 2017
Resolution: PA system was repaired and tested satisfactorily.
Electrical › Electric Generation Source (service) › Generator
Issued 30 May 2017
Resolved
Install derated placard on engine room generator, it's derated but not posted. IAW 46cfr183.320
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 20 June 2017
Resolution: Appropriate placard was installed on generator.
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 4 April 2017
Resolved
Provide documentation that the vessel was constructed out of fire retardant resin or provide a hull sample in the presence of the attending Marine Inspector and send that sample to an approved lab to determine the flame spread rating per ASTM E-84. Alternatively, install an approved fire detection system. 46 CFR 177.410
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 29 January 2020
Resolution: Completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 10 May 2016
Resolved
Both exhaust pipes in E/R need proper support to hold pipes IAW 46 CFR 182.15-20
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: Proper supports added and holding.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 10 May 2016
Resolved
Both cooling pipes for both main engines need proper supports IAW 46 CFR 182.15-15.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: Supports added and holding.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 May 2016
Resolved
Provide DAPI letter with all crew members on form with expiration dates IAW 46 CFR 16.113
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: DAPI letter provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2016
Resolved
Wire supports for rudder room, tank room, accommodation space, and E/R. Some missing, some broke, needed every 24" IAW 46 CFR 183.01-15
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: Added supports thru out spaces.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2016
Resolved
All flexible cords need removed and properly wired with fixed wire IAW 46 CFR 183.10-20.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: Cords removed and fixed wiring where needed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2016
Resolved
Railing near life floats needs tightened IAW 46 CFR 177.35-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: Railing was tightened.
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 10 May 2016
Resolved
Generator needs to have a 61 amp or lower breaker to meet de-rating IAW 46 CFR 183.10-5.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: 60 amp breaker added to gen set.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2016
Resolved
Guards needed for both main engines IAW 46 CFR 177.35-15.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: Guards added where needed.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 10 May 2016
Resolved
Look into shafts for both mains, find out if shaft flange is mounted correctly IAW 46 CFR 176.25-10.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 1 June 2016
Resolution: Shaft bolts added and tight.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 10 May 2016
Resolved
EPIRB is not registered to new owner. This limits vessel to less than 3NM route.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 10 May 2016
Resolution: Registered new EPIRB and received confirmation email.