MAURY USCG vessel records Sign in
← All vessels

RUDDERFISH

RUDDERFISH is a 1991 offshore supply vessel. The Coast Guard has recorded 33 inspections since 1991, most recently in February 2016, along with 49 deficiencies, 1 operational control and 1 casualty investigation in 2005.

Records from 1991 to 2016. Most recent: inspection, 19 February 2016.

Built
1991
Last inspected
19 February 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8767501 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC8205
368953
Flag
PANAMA
338416000, 367083310 (licence lapsed)
Maury page id
psix-368953

Inspections, by type

…with no type recorded2
Years with a record 14 calendar years (1991–2016)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it309 - Convention (Subpart B), Gross Ton
183 - Regulatory (Subpart C or D), Gross Ton
92 - Convention (Subpart B), Net Ton
112 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC8205MMSI 367083310 · expired · compulsorily equipped · granted 24 December 2005, cancelled 27 February 2016
WBC8840MMSI 338416000 · expired · compulsorily equipped · granted 2 October 1996, cancelled 3 March 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 33

19 February 2016 Deficiency Check
Physical examination · Activities Europe · Activity 5818038
28 October 2006 Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 2794819
19 June 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2684882
16 June 2006 Administrative Inspection
Administrative · Activities Europe · Activity 2681331
13 February 2006 Administrative Inspection
Administrative · Activities Europe · Activity 2584046
7 June 2005 Type not recorded
No type recorded · Activities Europe · Activity 2382270
15 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2292750
7 February 2005 Annual Inspection · Hull Examination · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2240975
22 June 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2107154
6 March 2004 Security Inspection · Annual Inspection
Physical examination · Activities Europe · Activity 2005124
25 October 2002 Type not recorded
No type recorded · Activities Europe · Activity 1695850
1 September 2002 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 1654988
1 November 2001 COI Inspection
Physical examination · Activities Europe · Activity 1475857
25 September 2001 Administrative
Administrative · Activities Europe · Activity 771995
29 January 2001 Deficiency Check
Physical examination · Activities Europe · Activity 1056758
3 January 2000 Deficiency Check
Physical examination · Activities Europe · Activity 1057387
9 November 1999 COI Inspection
Physical examination · Activities Europe · Activity 1125181
20 October 1999 Administrative
Administrative · Activities Europe · Activity 1125073
23 April 1999 Deficiency Check
Physical examination · Activities Europe · Activity 791052
18 January 1999 Administrative
Administrative · Activities Europe · Activity 1128630
5 January 1999 Deficiency Check
Physical examination · Activities Europe · Activity 811365
20 November 1998 Re-Inspection
Physical examination · Activities Europe · Activity 798894
22 November 1997 COI Inspection · Hull Examination
Physical examination · Activities Europe · Activity 1368831
17 October 1997 Administrative
Administrative · Activities Europe · Activity 1111072
20 June 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 881471
6 October 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826247
16 September 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1146156
11 March 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 839059
17 November 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1133734
9 October 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373758
29 July 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1269584
7 July 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957110
17 December 1991 Hull Examination · Plan Review "T" Boat · Inclining Experiment · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 948903

Deficiency record · 49

Lifesaving › Inflatable Liferafts › Not on Board
Issued 28 October 2006 Resolved
Installed liferafts as required by 46 CFR 133.10. Due change in determination of requirement to carry liferafts, due date is for end of next inspection window. 835 issued by e-mail dated 16 Oct 06. VESSEL MUST COMPLETE THIS ISTALLATION IF EVER COME BACK TO US FLAG.
Action required: 705 - Other - as specified
Due 15 January 2020
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Structures › Superstructure
Issued 7 February 2005 Resolved
Replace broken Stbd aft corner Bridge window. 09Mar05 Received e-mail from Master stating item has been cleared, Item will remain opened until cleared by the next attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 17 October 2005
Documentation › Markings/Placards › Official Number (US)
Issued 7 February 2005 Resolved
Replace tattered AMERICAN FLAG with new. 09Mar05 Received e-mail from Master stating item has been cleared, Item will remain opened until cleared by the next attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 17 October 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 7 February 2005 Resolved
Repair/replace middle shower hot water knob on upper level. 09Mar05 Received e-mail from Master stating item has been cleared, Item will remain opened until cleared by the next attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 17 October 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 7 February 2005 Resolved
Repair/Replace leaking potable water hoses under galley sink. 09Mar05 Received e-mail from Master stating item has been cleared, Item will remain opened until cleared by the next attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 17 October 2005
Engineering › Fuel Oil Service System › Valve
Issued 7 February 2005 Resolved
Remove securing seal from emergency fuel shut off 's and replace with easily removable securing devices. i.e pad locks. 09Mar05 Received e-mail from Master stating item has been cleared, Item will remain opened until cleared by the next attending Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 17 October 2005
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 7 February 2005 Resolved
Stbd engine room exhaust cover dog needs maintenance. 09Mar05 Received e-mail from Master stating item has been cleared, Item will remain opened until cleared by the next attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 17 October 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 February 2005 Resolved
Properly install main deck electrical panel cover in laundry room. 09Mar05 Received e-mail from Master stating item has been cleared, Item will remain opened until cleared by the next attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 17 October 2005
Personnel › Training › Familiarization Training
Issued 7 February 2005 Resolved
Provide more security training for crew members. 09Mar05 Received e-mail from Master stating item has been cleared, Item will remain opened until cleared by the next attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 17 October 2005
Construction/Loadline › Hull › Transverse Frame
Issued 7 February 2005 Resolved
Complete steel repairs as per vessel work plan and provide copy of final repair plan with UT's of spud cans and connection areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2006
Resolved 3 May 2005
Resolution: Item recieved
Construction/Loadline › Hull › Keel
Issued 7 February 2005 Resolved
Provide photos of all bulkheads replacement areas with particular attention area of thru frames.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2006
Resolved 3 May 2005
Resolution: Photo''s recieved.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 6 March 2004 Resolved
Replace missing flame screens as needed, Item reported cleared via e-mail but, will remain open until verified at next attendance. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 7 February 2005
Engineering › Bilge Water Management System › Piping
Issued 6 March 2004 Resolved
Install bilge rosebud screen over bigle suction in Port engine room. Item reported cleared via e-mail but, will remain open until verified at next attendance LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 7 February 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 6 March 2004 Resolved
Install a backflow preventer on F/O purifier. Item reported cleared via e-mail but, will remain open until verified at next attendance LEGACY COMPONENT DESC: System
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 7 February 2005
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 6 March 2004 Resolved
Provide MSC approval for OWS Installation. Item reported cleared via e-mail but, will remain open until verified at next attendance or copy of letter received. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 7 February 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 6 March 2004 Resolved
Replace/Repair washing machine due to present machine dumps water all over the deck. Item reported cleared via e-mail but, will remain open until verified at next attendance. LEGACY COMPONENT DESC: Laundry
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 7 February 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 March 2004 Resolved
Update first aid kit. Item reported cleared via e-mail but, will remain open until verified at next attendance. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2005
Resolved 6 February 2005
Lifesaving › Lifeboat Equipment › Dipper
Issued 5 March 2004 Resolved
Update Lifeboat Equipment IAW 46 CFR 133.175. Item reported cleared via e-mail but, will remain open until verified at next attendance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 6 February 2005
Fire Fighting › Fire Main › Condition
Issued 1 September 2002 Resolved
Entire fire main is suspect due to condition of main in engine room. Provide UT report of entire fire main condition, renew as necessary.
Condition: Improper/Lack of Maintenance
Due 3 January 2003
Resolved 3 January 2003
Deck/Cargo › Ballast › Piping
Issued 1 September 2002 Resolved
Entire bilge/ballast piping system suspect due to condition of all piping in engine room. UT entire bilge and ballast piping system, renew where necessary.
Condition: Improper/Lack of Maintenance
Due 3 January 2003
Resolved 3 January 2003
Construction/Loadline › Structures
Issued 1 September 2002 Resolved
Vessel must proceed to complete credit dry dock and ISE. LEGACY COMPONENT DESC: Hull
Condition: Unknown
Due 3 January 2003
Resolved 4 January 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 1 September 2002 Resolved
Renew portable fire extinguishers #5,8,13 with USCG approved marine type fire extinguishers. LEGACY COMPONENT DESC: Non USCG approved
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 February 2003
Resolved 6 March 2004
Resolution: Corrected
Fire Fighting
Issued 1 September 2002 Resolved
Provide proper fire extinguisher bracket for all portable extinguishers. LEGACY COMPONENT DESC: Brackets
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 February 2003
Resolved 6 March 2004
Resolution: Corrected
Navigation
Issued 1 September 2002 Resolved
Provide light for compass. Vessel is restricted to daylight operations until repaired. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2003
Resolved 6 March 2004
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 1 September 2002 Resolved
Vessel and Company to comply with 46 CFR Part 16.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 February 2003
Resolved 3 May 2005
Resolution: Unable to comply in Nigeria, No HQ response to correction. Cg 835 to be reissued after HQ addresses issue.
Construction/Loadline › Structures
Issued 1 September 2002 Resolved
Prior to 2004 inspection make proper permanent repairs to port fuel tank outer and aft bulkheads and internal. Tank appears to have been over-pressurized. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 6 March 2004
Resolution: Corrected
Construction/Loadline › Structures
Issued 1 September 2002 Resolved
Prior to 2004 inspection make proper permanent repairs to bulkhead between #5 starboard ballast tank and engine room. Bulkhead has a 90 degree insert. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 6 March 2004
Resolution: Corrected
Construction/Loadline › Structures
Issued 1 September 2002 Resolved
Prior to 2004 inspection make proper permanent repairs to forward bulkhead of rudder room starboard side to remove a 90 degree insert IWO starboard void. Repair must continue into starboard fuel tank at least 6" and have 100% penetration welds. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 6 March 2004
Resolution: Corrected
Navigation › Piloting/Steering
Issued 1 November 2001 Resolved
No record of chart corrections LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Due 1 December 2001
Resolved 3 December 2001
Resolution: Cleared by fax
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 November 2001 Resolved
Provide legible copies of fire control plan.
Due 1 December 2001
Resolved 3 December 2001
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 1 November 2001 Resolved
Replace discharged CO2 extinguisher at entrance to engine space (extinguisher in excess to those required). LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Due 1 December 2001
Resolved 3 December 2001
Lifesaving
Issued 20 November 1998 Resolved
Provide proper dogging wrenches for hatches. Submit copy of ships log, signed by Master stating proper dogging wrenches are on station to clear deficiency.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Lifesaving
Issued 20 November 1998 Resolved
Update station bill to reflect actual duties of crew onboard. Submit copy of new bill to MIO Europe to clear deficiency.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Accommodation/Occupational Safety
Issued 20 November 1998 Resolved
Replace gaskets on emergency exits from engine room. Submit copy of ships log signed by Master to MIO Europe to clear requirement.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Construction/Loadline
Issued 20 November 1998 Resolved
Vee and weld crack in the weld of the attachment brace (jack house) to forward bulkhead.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Fire Fighting
Issued 20 November 1998 Resolved
Provide recent copy of servicing report for portable fire extinguishers. Send report to MIO Europe to clear requirement.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Lifesaving
Issued 20 November 1998 Resolved
Submit an accurate fire /safety plan to MIO Europe for review.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Construction/Loadline
Issued 22 November 1997 Resolved
Operationally test bilge and ballast system.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Navigation
Issued 22 November 1997 Resolved
Provide tide/current tables.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Lifesaving
Issued 22 November 1997 Resolved
Provide servicable lifejackets for 31 persons.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Engineering
Issued 22 November 1997 Resolved
Prove proper operation of main engine/generators overspeed trips and alarms.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Engineering
Issued 22 November 1997 Resolved
Prove proper operation of main engine/generators low lube oil trips and alarms.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Engineering
Issued 22 November 1997 Resolved
Prove proper operation of main engine/generators high jacket water temperature alarms._x001C_
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Engineering
Issued 22 November 1997 Resolved
Hydrostatically test or perform an internal examination of installed air receivers.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Navigation
Issued 22 November 1997 Resolved
Prove proper operation of the navigation light alarm panel iaw 46CFR111.175-16.
Condition: Unknown
Due 22 November 1997
Resolved 22 November 1997
Navigation
Issued 22 November 1997 Resolved
Provide notice to mariners.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Lifesaving
Issued 22 November 1997 Resolved
Renew ring buoy water light. _x001C_
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Engineering
Issued 22 November 1997 Resolved
Bench test air receiver relief valves.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Documentation
Issued 9 October 1992 Resolved
PROVIDE LOADLINE ON BOARD VESSEL AS PER 46CFR 42.03-5(b) AND MSM VOL IV SECTION 6.F. UPON COMMMENCING DOMESTIC VOYAGES.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992

Casualty record · 1

7 June 2005Routine · role: Involved in a Marine Casualty · activity 2382270
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

AIMEE DANOS (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record