MAURY USCG vessel records Sign in
← All vessels

SITAVERA

SITAVERA is a 1989 tank ship. The Coast Guard has recorded 18 inspections since 1991, most recently in February 2008, along with 7 deficiencies and 5 operational controls.

Records from 1991 to 2008. Most recent: operational control imposed, 6 February 2008.

Built
1989
Last inspected
6 February 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8715510 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
368996
Flag
NORWAY
—
Maury page id
psix-368996

Inspections, by type

…with no type recorded9
Years with a record 10 calendar years (1991–2008)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it84040 - Dead Weight, Ton
98870 - Displacement, Ton
19867 - Simplified, Net Ton
19867 - Convention (Subpart B), Net Ton
43414 - Simplified, Gross Ton
43414 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

6 February 2008 MARPOL Annex I Examination · COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3143124
25 January 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3136522
14 August 2006 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2747836
19 August 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2467960
10 August 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex II Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2457920
8 August 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2455922
23 February 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2302703
22 June 2004 NPV Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2106616
27 May 2004 MARPOL Annex V Examination · MARPOL Annex I Examination · Certificate of Compliance · MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2079551
14 May 2002 Tank Vessel Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1616501
24 February 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 274847
24 February 2000 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1466659
4 July 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 418478
7 November 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 409777
21 September 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 407953
25 June 1994 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1333892
25 November 1991 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 347410
25 November 1991 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 938387

Deficiency record · 7

Lifesaving › Launching Appliances › Davit
Issued 6 February 2008 Resolved
Vessels portside lifeboat gravity brake does not stop the descent of the lifeboat when the break is manually released. Vessel shall submit documentation from the certificate issuing authority attesting to the proper repairs and full operation of the vessel's manual (gravity) brake.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2008
Resolution: Received tech report attesting to the proper repairs and operation of the vessel''s port and starboard lifeboat gravity breaks.
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Pilot (air start)
Issued 25 January 2008 Resolved
Vessel unable to start engine from pilot house controls.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2008
Resolution: Received satisfactory class report.
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 19 August 2005 Resolved
On August 04, 2005, while en route to the Port of New York, we received a report of cargo migration into the subject vessel's No. 2 Port ballast tank from a breach in way of the No. 3 Port cargo tank. Subsequently, it has been reported that the crew has taken steps to arrest the leak and removed all traces of gasoline in the No. 2 Port ballast tank, except for the stool space.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2005
Resolution: AS PER CLASS A TEMPORARY REPAIR WAS MADE; SEE ATTATCHED DOCUMENT.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 27 May 2004 Resolved
The air conditioner installed in the cargo control room and extends into the gymnasium penetrates the bulkhead which is rated "A" class.
Action required: 705 - Other - as specified
Due 27 June 2004
Resolved 22 June 2004
Resolution: Received Class report from Det Norske Veritas showing item has been corrected. See DNV Report #8114058 showing item has been corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 14 May 2002 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPATOR SYSTEM TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO DEPARTURE FROM THE PORT OF NEW YORK. ( OIL FOUND IN DISCHARGE SIDE) LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2002
Resolution: Recvd DNV report #15713 on 14MAY02, attesting to the proper operation of the 15 ppm OWS system. Problem was determined to be malfunctioning 3-way valve. Valve piping was cleaned, 3-way valve repaired, and the system was tested & found in good order.
Deck/Cargo
Issued 21 September 1997 Resolved
Inoperable cargo discharge monitor. Provide servicing statement attesting to proper operation NLT 21Oct97. 33 CFR 157.12
Condition: Unknown
Due 11 November 1997
Resolved 11 November 1997
Deck/Cargo
Issued 21 September 1997 Resolved
Overflow alarm not labeled on deck. Label overfill alarm on deck prior to loading cargo. 33 CFR 155.480
Condition: Unknown
Due 11 November 1997
Resolved 11 November 1997

Ownership record