MAURY USCG vessel records Sign in
← All vessels

CAMILLA DESGAGNES

CAMILLA DESGAGNES is a 1982 freight ship. The Coast Guard has recorded 30 inspections since 1991, most recently in March 2009, along with 19 deficiencies — 4 with no resolution recorded — and 3 operational controls.

Records from 1991 to 2009. Most recent: operational control imposed, 27 March 2009.

Built
1982
Last inspected
26 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8100595 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
369032
Flag
BARBADOS
—
Maury page id
psix-369032

Inspections, by type

…with no type recorded22
…past their stated due date4
Years with a record 15 calendar years (1991–2009)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it7340 - Dead Weight, Ton
4680 - Convention (Subpart B), Net Ton
10085 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

26 March 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3440799
5 March 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3428341
27 December 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3385272
10 December 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3377719
13 April 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2907399
28 March 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2896874
25 March 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2894540
12 June 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2677941
10 April 2006 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2621337
9 March 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2599133
10 June 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2386286
8 June 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2435445
4 January 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2268789
3 January 2005 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2267748
8 December 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2255468
7 February 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1484778
19 November 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 295665
22 May 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 290246
21 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288303
3 October 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 282686
24 October 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 396649
23 October 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 384015
5 October 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 647523
2 October 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 441403
3 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 463744
13 October 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 463147
13 April 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 357589
30 December 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 355389
15 January 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 647603
18 November 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 533572

Deficiency record · 19

Construction/Loadline › Structures › Deck Plating
Issued 13 December 2008 Resolved
Several steps on various exterior ladders on the superstructure decks were found to have 25-40% wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2009
Resolved 5 March 2009
Resolution: VESSEL REPLACED STEPS ON ALL LADDERS IN QUESTION
Lifesaving › Lifeboat Equipment › Food Ration
Issued 9 March 2006 Resolved
Replace damaged food rations for lifeboats, 7 starboard and 18 port. Cite: SOLAS 74 A Ch. III/34 LSA Code 4.4.8.12
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2006
Resolved 9 March 2006
Resolution: Deficiency rectified on spot.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 March 2006 Resolved
Vessel does not have tidal currents for the area of operation. Cite: 33 CFR 164.33 (a) 3(ii)
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 March 2006
Resolved 24 March 2006
Resolution: Recieved receipt by fax for purchase of 2006 Tidal Currents - Atlantic coast of america.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 December 2004 Resolved
PROVIDE ADEQUATE SUPPLY OF FILM USED AS IGNITION FOR SECONDARY MEANS OF STARTING EMERGENCY GENERATOR.
Condition: Improper/Lack of Maintenance
Due 8 January 2005
Resolved 3 January 2005
Resolution: MSO Philadelphia personnel inspected adequate supply of film for starting em,ergency generator.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 December 2004 No resolution recorded
INSTALL COVER FOR EMERGENCY GENERATOR COOLING FAN.
Condition: Unknown
Due 8 January 2005 — due date passed with no resolution recorded
Resolution: MSO Philadelphia personnel inspected newly installed shield over emergency generator fan.
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 8 December 2004 No resolution recorded
LOADLINE CLASS MARKINGS TO BE MADE PERMANENTLY.
Due 8 January 2005 — due date passed with no resolution recorded
Resolution: MSO Philadelphia personnel inspected permanently affixed class markings for loadline.
Operations/Management › Drills/Instruction › Fire
Issued 8 December 2004 No resolution recorded
Abandon Ship and Fire Drills not conducted due to bunkering operations and vsl's departure schedule. Conduct drills in conjunction with Deficiency Check within 30 days.
Action required: 705 - Other - as specified
Due 8 January 2005 — due date passed with no resolution recorded
Resolution: MSO Philadelphia personnel witnessed satisfactory fire and abandon ship drills.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 December 2004 No resolution recorded
INSTALL PANELS ON BACK SIDE OF MAIN SWITCHBOARD AND EMERGENCY SWITCHBOARD.
Due 8 January 2005 — due date passed with no resolution recorded
Resolution: MSO Philadelphia personnel inspected newly installed panels on back of main and emergency switchboards.
Accommodation/Occupational Safety
Issued 19 November 2001 Resolved
VESSELS TO RELACE/RENEW CORRODED LADDER RUNGS (3 IN ALL) ON LADDERS LOCATEDOUTSIDE AND ABOVE ACCOMADATION SPACES THAT LEAD TO THE BRIDGE. MASTER TO PROVIDE STATEMENT TO COAST GUARD WHEN CORRECTED.
Condition: Unknown
Due 20 November 2001
Resolved 7 December 2001
Resolution: MSO PORTLAND (MAINE) WENT ONBOARD AND CLEARED DEFICIENCY, BUT CASEWORK WAS NOT DONE. MSO PHILADELPHIA REC''D FAXED COPY OF BOARDING REPORT STATING DEFICIENCY WAS CLEARED, AND CLEARED DEFICIENCY FROM CASE.
Navigation
Issued 3 October 2000 Resolved
MISSING BRITISH ADMIRALTY LIGHT LIST VOL. J 47TH ED. OR ITS EQUIVALENT
Condition: Unknown
Due 5 October 2000
Resolved 4 October 2000
Lifesaving
Issued 3 October 2000 Resolved
CREW UNABLE TO CONDUCT A SATISFACTORY FIRE DRILL A VIOLATION OF SOLAS 74/78CHAPTER III REGULATION 18/3.10. CONDUCT A SATISFACTORY FIRE DRILL IN PRESENCE OF COAST GUARD BOARDING TEAM BEFORE VESSEL DEPARTURE.
Condition: Unknown
Due 5 October 2000
Resolved 6 October 2000
Lifesaving
Issued 3 October 2000 Resolved
MUSTER LISTS AND EMERGENCY INSTRUCTIONS WERE NOT EXHIBITED IN CONSPICUOUS PLACES THROUGHOUT VESSEL, A VIOLATION OF SOLAS 74/78 CHAPTER III REGULATION9. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 5 December 2000
Resolved 5 December 2000
Accommodation/Occupational Safety
Issued 3 October 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Lifesaving
Issued 3 October 2000 Resolved
DURING ANNUAL FREIGHT EXAM, VESSEL WAS UNABLE TO CONDUCT A SATISFACTORY ABANDON SHIP DRILL AS REQUIRED BY SOLAS 74/78 CHAPTER III REG 18/3.4.5. PORT LIFEBOAT DID NOT LOWER/PROVIDE PROPER OPERATION OF LIFEBOAT WINCH AS REQUIRED BY SOLAS 74/78 CHAPTER III REG 19/3. CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 5 October 2000
Resolved 6 October 2000
Lifesaving
Issued 24 October 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Navigation
Issued 30 December 1992 Resolved
VESSEL HAD NO U.S. COAST PILOT FOR AREA TRANSITTED ON BOARD.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Navigation
Issued 30 December 1992 Resolved
VESSEL FAILED TO LOG PRE ARRIVAL TESTS IN ACCORDANCE WITH 33 C.F.R. 164.11q
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Unknown
Issued 30 December 1992 Resolved
DESCRIPTION AND PROCEDURE FOR EMPTYING MANIFOLD CONTAINMENT NOT INCORPORATED INTO OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 C.F.R. 155.750(a)(2)(iii).
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Unknown
Issued 30 December 1992 Resolved
PROCEDURES FOR REPORTING OIL DISCHARGES INTO THE WATER WERE NOT INCORPORATED INTO THE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 C.F.R. 155.750(a)(9).
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.