Records from 2003 to 2026. Most recent: inspection, 10 April 2026.
Inspection history · 30
10 April 2026
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8346018
6 June 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8153857
24 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8116320
2 October 2024
Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8012948
5 September 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7972252
3 November 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7685246
6 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7685312
7 April 2023
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7657923
22 August 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7528890
9 August 2022
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7506455
27 April 2022
Examination of Repairs · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7439283
4 November 2021
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7346025
1 October 2021
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7324069
4 June 2021
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7202007
6 May 2021
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7184966
3 September 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7038881
18 October 2019
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6838528
19 September 2019
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6816730
10 September 2019
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808185
3 September 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6802911
17 June 2019
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6713155
27 August 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6524174
19 June 2018
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6434701
8 June 2017
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6146824
5 May 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6136937
5 February 2017
Type not recorded
No type recorded · Station Point Judith · USCG Northeast District (CGD-NE) · Activity 6082941
27 June 2016
Type not recorded
No type recorded · Station Point Judith · USCG Northeast District (CGD-NE) · Activity 5923109
27 June 2016
Damage Survey · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5934038
27 June 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5939217
16 February 2016
Administrative Inspection · COI Inspection · DAPI Audit · Plan Review "T" Boat · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5815887
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 April 2026
Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted to be on board. One of the two 50 person IBA's has been removed for servicing. Total persons on board has been reduced to 50.
Action required: 705 - Other - as specified
Resolved 14 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 April 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Renew the grabline on the vessel's ring life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 13 April 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 April 2026
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Renew the flame screen on the stbd side fuel vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 13 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 April 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Renew the MOB ladder securing line and crew tether.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 13 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 April 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Clean the engine room ventilation screens located on the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 13 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 April 2026
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Replace missing breakers or dead front covers on the electrical panels located at the engine room entrance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 13 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 April 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Wire in engine room outer sheathing broken.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 13 April 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 October 2024
Resolved
Passenger count reduced by 1 passenger on all routes and conditions permitted on the vessel's Certficate of Inspection. Provide USCG Marine Safety Center stability review letter addressing weight changes associated with the installation of the new Northern Lights M20CR generator.
Action required: 705 - Other - as specified
Due 2 October 2024
Resolved 11 October 2024
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 5 September 2024
Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Glass or other glazing material used in windows at the operating station must have a light transmission of not less than 70 percent. The window located on the port side pilothouse door has a large spider crack, restricting operating station visibility. 46 CFR 177.1030
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2024
Resolved 26 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
Electrical equipment on a vessel must minimize accidental personal contact with energized parts. Outlet cover in passenger lounge cracked.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 June 2023
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
Electrical equipment on a vessel must minimize accidental personal contact with energized parts. Found cable in tank room chafed.
Action required: 10 - Deficiency Rectified
Resolved 6 June 2023
Resolution: Section of cable removed.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 6 June 2023
Resolved
Two flexible non-metallic hoses for the winch/capstan penetrate the watertight main deck. Each penetration must be accomplished using an acceptable metallic through deck fitting that is welded or otherwise attached to the deck by an accepted method; and one metallic shutoff valve must be installed if operable from above the bulkhead deck.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 18 June 2024
Resolution: Special Consideration issued. See Documents.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 August 2022
Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to passengers or where the crew may be quartered or normally employed, so located that if one is not available the other may be. Found Engine room escape hatch rotten, swollen and unable to open. Crew freed hatch and removed part of the rotten material. Submit a repair proposal to this office; effect permanent repairs to the hatch and surrounding material once approval is given to proceed. Until permanent repairs are made, the hatch shall be exercised for proper operation prior to each voyage. 46 CFR 177.15-1
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2022
Resolved 22 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 August 2022
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Found bulkhead between tank room and engine room with wire run improperly sealed between center and stbd tanks. 46 CFR 171.114(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 23 September 2022
Resolution: Sealed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 August 2022
Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. Port battery bank #2 found unsecured. Crew screwed box in, puncturing box. Replace and secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 25 August 2022
Resolution: Vessel representative created 2x4 curbing to hold battery box in place to the satisfaction of the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 August 2022
Resolved
All connections shall be made to the battery terminals with permanent type connectors. Forward port battery found with a wing nut on its positive terminal. Replace with standard nut. 46 CFR 183.05-20 (c)
Action required: 10 - Deficiency Rectified
Due 22 August 2022
Resolved 22 August 2022
Resolution: Vessel crew replaced wing nut to the satisfaction of the attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 August 2022
Resolved
A vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. Vessel's backup paper charts found uncorrected since 2020. Update charts to the satisfaction of the attending marine inspector. 46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 23 September 2022
Resolution: New charts purchased.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 August 2022
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Found refrigerator in galley plugged in with extension cord. Remove extension cord and extend circuit to the satisfaction of the attending marine inspector. 46 CFR 183.10-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 23 September 2022
Resolution: Cord replaced.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 22 August 2022
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeter numbers and letters at the entranceway to that deck. Upper deck passenger maximum marked 69, stability letter indicates a maximum of 64. 46 CFR 185.602(g)
Action required: 10 - Deficiency Rectified
Due 22 August 2022
Resolved 22 August 2022
Resolution: Vessel crew corrected number of permitted passengers on second deck to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 August 2022
Resolved
The Certificate of Inspection and any SOLAS certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Original Certificate of Inspection was not on board the vessel, a photocopy was kept on the bridge. 46 CFR 176.302
Action required: 10 - Deficiency Rectified
Due 22 August 2022
Resolved 22 August 2022
Resolution: Vessel Representative placed original COI onboard the vessel to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 August 2022
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel did not have the original Certificate of Documentation on board. 46 CFR 67.313(a)
Action required: 10 - Deficiency Rectified
Due 22 August 2022
Resolved 22 August 2022
Resolution: Vessel representative placed the orgininal COD onboard the vessel to the satisfaction of the attending marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 August 2022
Resolved
Vessels constructed of wood must provide bilge level alarms in all watertight compartments except small buoyancy chambers. Vessel does not have bilge level alarm in forward void. 46 CFR 182.530(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2022
Resolved 7 September 2022
Resolution: Bilge alarm installed and tested.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 17 August 2022
Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. Submit detailed plans for your proposal to include general arrangement/locations and bill of materials for the installation to include cable sizes/length for plan approval and install the system prior to 30Sep2022.
Action required: 705 - Other - as specified
Due 30 September 2022
Resolved 17 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 27 April 2022
Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. The monitoring device must ensure the wakefulness of the crew in the event that the watchman is unresponsive; Remain operable during the nighttime watch; and Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Submit plans to the OCMI by 27May2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2021
Resolved
New installation of boiler has not been tested/inspected. Provide 3rd party servicing/testing to the satisfaction of the attending USCG Marine Inspector prior to placing boiler into service.
Action required: 705 - Other - as specified
Due 1 September 2021
Resolved 18 March 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Install blanks missing in pilot house panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Blanks installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Remove dead end wires in pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 30 September 2020
Resolution: Wires removed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2020
Resolved
Relabel life jackets with vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Life jackets relabeled. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Properly hardwire lights in galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Lights replaced and wired properly. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Hardwire light in E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 30 September 2020
Resolution: Light hardwired. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Remount battery switches in E/R for center and stbd engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Switches remounted. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Remove dead end battery cable IWO center engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 30 September 2020
Resolution: Cable removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Remove hardwired extension cord in E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 30 September 2020
Resolution: Extension cord removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Install proper size cable for air compressor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 30 September 2020
Resolution: Proper size cable and circuit breaker added to circuit. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 September 2019
Resolved
Update emergency instructions/station bill to include designated crew member as a watch patrolman.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019
Resolved
Update log book to organize weekly, monthly, quarterly, and annual inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019
Resolved
Provide a means to log watch patrolman rounds when watch patrolman is required to be conducting rounds.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019
Resolved
Create a voyage plan to be included with passenger count/lists when making overnight voyages.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019
Resolved
Provide documentation/check list to include records of instruction of each crew member of their duties, responsiblities, and ability/knowledge/familiarization of the location and to utilize all emergency equipment as per 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 September 2019
Resolved
Update passenger safety orientation to include the request of passengers to don a life jacket when on a voyage of more than 24 hrs as per 46 CFR 185.506(e).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2019
Resolved
Provide documentation that smoke detectors meet UL 217 standard as per 46 CFR 181.450.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 September 2019
Resolved
Provisions must be made for closing all supply duct cowls or scoops. The ventilation closure at the entry to the engine room could not properly seat when pulled.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 3 September 2019
Resolved 3 September 2019
Resolution: Crew adjusted the ventilation closure to ensure it fell and seated when pulled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 September 2019
Resolved
On a vessel of more than 65 feet in length, each hose must be lined commercial fire hose. The starboard side fire hose was found worn and leaking.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 3 September 2019
Resolved 3 September 2019
Resolution: The crew replaced the fire hose in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2019
Resolved
All cables and wire must be installed with metal supports spaced not more than 24 inches apart. The wire runs above the main engines were found to be supported by plastic wire ties.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 16 September 2019
Resolution: The the crew installed metal supports for the wire runs over the main engines.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 September 2019
Resolved
The installation and location must be to the satisfaction of the OCMI. The portable fire extinguisher in the forward passenger bunk room was found not permanently mounted or in a approved bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 16 September 2019
Resolution: The crew installed the appropriate bracket for the portable fire extinguisher in the forward passenger bunk room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 June 2019
Resolved
Prove proper operation of 6 sea valves as follows: 1) Port, Center, and Stbd MDE ball sea valves, Stbd side aft E/R, Port side aft E/R, and Grey water discharge in tank room prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: No static draft information and is not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 14 October 2018
Resolution: Corrected deficiency on AIS transmittals
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 June 2018
Resolved
Paint the sidelight screens mat black
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2018
Resolved 27 June 2018
Resolution: Side boards painted.
Lifesaving › Lifebuoys › Stowage
Issued 19 June 2018
Resolved
Relocate the ring buoy from forward of the pilothouse to the main deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2018
Resolved 27 June 2018
Resolution: Relocated to main deck aft.
Engineering › Fuel Oil Service System › Filter
Issued 19 June 2018
Resolved
Replace the Racor diesel plugs X8 to metal
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2018
Resolved 9 July 2018
Resolution: Completed install of metal plus/ caps to filter drains.
Fire Fighting › Fire Hoses › Condition
Issued 19 June 2018
Resolved
Replace 1 50 foot fire hose
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2018
Resolved 27 June 2018
Resolution: New fire hose installed on stbd side fire station.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 19 June 2018
Resolved
Remove hydraulic fluid from the forward berthing area bilges
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 19 June 2018
Resolution: Correct on spot
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 May 2017
Resolved
Shorten line on ring buoy float light.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 17 May 2017
Resolution: Shortened line on ring buoy float light.
Fire Fighting › Fire Hydrants › Condition
Issued 5 May 2017
Resolved
Replace ball valve on port fire station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 17 May 2017
Resolution: Replaced ball valve on port fire station.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 5 May 2017
Resolved
Replace fire extinguisher bracket in wheel house.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 17 May 2017
Resolution: Replaced fire extinguisher bracket in wheel house.
Construction/Loadline › Structures › Superstructure
Issued 27 June 2016
Resolved
Make temporary repairs to gunwale and head where damaged to the satisfaction of the attending USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2016
Resolved 30 June 2016
Construction/Loadline › Structures › Superstructure
Issued 27 June 2016
Resolved
Make permanent repairs to stbd gunwale where damaged prior to 01Mar2017.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 29 June 2017
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 June 2016
Resolved
Provide current copy of Eldridge book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Communications › Audible Communications › Bell
Issued 9 June 2016
Resolved
Bell is missing clacker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 9 June 2016
Resolved
One life float is missing the waterlight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Resolution: Life floats were removed from the vessel and IBAs installed in their place.
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 9 June 2016
Resolved
Life floats are not installed in thier proper location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Resolution: Lifefloats were removed from vessel.
Documentation › Markings/Placards › Capacity Marking
Issued 9 June 2016
Resolved
Stencil max number of passengers for the 02 deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 June 2016
Resolved
Center MDE is missing guard on front of engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Operations/Management › Drills/Instruction › Fire
Issued 9 June 2016
Resolved
Conduct MOB and Fire drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016