MAURY USCG vessel records
← All vessels

LETOJANNI

Built
1977
Last inspected
28 December 2007
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 28 December 2007
…with no type recorded3
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (1998–2007)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7601645
369287
Flag
ITALY
Maury page id
psix-369287

Documentation record

Tonnage as PSIX records it705 - Convention (Subpart B), Gross Ton
734 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 9 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

28 December 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3121746
23 December 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3120017
17 April 2007 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2909273
8 March 2007 Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2874637
8 December 2006 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2836851
27 November 2006 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2828008
23 March 2006 PII Safety Exam · ISPS I Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2608395
29 April 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 415081
16 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413813

Deficiency record · 12

Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 23 December 2007 Resolved
vessel's marine sanitation device failed because the pump that draws sewage onto the tank is missing, the vessel has blanked off the pipe that leads to where the pump was and have diverted the sewage directly overboard. vessel is to close and lock overboard discharge valve and maintain records and receipts of sewage discharges to reception facilities and/or trucks.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 December 2007
Resolved 27 December 2007
Resolution: vessel has closed and locked discharge valve and is prepared to provide receipts when it discharges to facility. vessel was issued NOV for discharging into the port of Tampa
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 December 2007 No resolution recorded
oil content meter is inoperable. vessel is not discharge overboard until the equipment is repaired and properly operating .
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 December 2007 Resolved
vessels nautical publications are out of date. vessel is to replace prior to departure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 December 2007
Resolved 27 December 2007
Resolution: vessel replaced all out of date nautical publications
Fire Fighting › Fire Main › Condition
Issued 18 April 2007 Resolved
Fire Line (portside) leaked during test of fire system. Temporary repairs were made while in Brownsville, Texas. Permanent repairs are to be made to satisfaction of attending class prior to returning to US.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 December 2007
Resolution: vessel has replaced and repaired the fire line on the port side.
Lifesaving › Inflatable Liferafts › Painter
Issued 8 March 2007 Resolved
Liferaft on superstucture aft of bridge and stbd raft rigged improperly. Liferaft painter systems were attatched to permanent fixture on vessel instead of the weak- link. SOLAS (Consolidated Edition 2004) CH lll REG 13.4.2 LSA Code 4.1.6.1.
Condition: Improper Installation
Due 8 March 2007
Resolved 8 March 2007
Resolution: Veesel fixed problem on the scene by reinstalling the painter to the weak link.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 8 March 2007 Resolved
Port and Stbd gyro compass repeaters do not read the same as the main gyro compass. The readings are as follow: main - 292, port - 092, and stbd - 346. Cite SOLAS (Consolidated Edition 2004) CH 1 REG 11.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 18 April 2007
Resolution: Gyro Compass Deficiency Cleared.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 8 March 2007 Resolved
Vsl does not have a waste management plan onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 18 April 2007
Resolution: Deficiency Cleared.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 March 2007 No resolution recorded
VSL does not have a Nontank Vessel Responce Plan and does not have proof of submittal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2007 — due date passed with no resolution recorded
Navigation
Issued 16 March 1998 Resolved
PROVIDE OPERATING INSTRUCTIONS AND BLOCK DIAGRAM FOR EMERGENCY STEERING.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Documentation
Issued 16 March 1998 Resolved
PROVIDE ONBOARD A GARBAGE RECORD LOG.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Electrical
Issued 16 March 1998 Resolved
WATER LEAK ON LUBE OIL PUMP GEAR ELECTRIC PANEL.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Engineering
Issued 16 March 1998 Resolved
PROVE PROPER OPERATION OF OWS SYSTEM.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998

Ownership record