MAURY USCG vessel records Sign in
← All vessels

SIOUX MAIDEN

SIOUX MAIDEN is a 1989 freight ship. The Coast Guard has recorded 25 inspections since 1991, most recently in March 2010, along with 7 deficiencies and 2 operational controls.

Records from 1991 to 2010. Most recent: inspection, 25 March 2010.

Built
1989
Last inspected
25 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8901133 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
369567
Flag
PHILIPPINES
—
Maury page id
psix-369567

Inspections, by type

…with no type recorded15
Years with a record 15 calendar years (1991–2010)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it42248 - Dead Weight, Ton
48754 - Displacement, Ton
13807 - Regulatory (Subpart C or D), Net Ton
13807 - Convention (Subpart B), Net Ton
23270 - Regulatory (Subpart C or D), Gross Ton
23270 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

25 March 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3702481
23 February 2009 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3416046
20 February 2009 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3422227
7 February 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2868184
3 February 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2866568
19 January 2007 Type not recorded
No type recorded · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 2858507
17 July 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2715848
15 November 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2535290
14 November 2005 ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2533661
10 August 2004 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2161698
2 August 2004 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2153696
1 July 2004 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2116797
13 May 2004 Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2066865
11 May 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2065391
27 August 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1890215
21 October 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1690940
20 June 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 291146
14 April 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 289047
5 November 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 434594
4 November 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 422269
23 February 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 401270
3 May 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 390862
8 July 1995 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 380423
10 February 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 375038
26 November 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 347229

Deficiency record · 7

Engineering › Steam System (main) › Piping
Issued 25 March 2010 Resolved
0999 All machinery and associated pipe fittings shall be installed and protected to minimize danger to persons onboard. 02 steam leaks are visible on 02 valves located on waste oil tank next to the incinerator. Solas 74 (2004 consolidated) chII-I, Reg 26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 April 2010
Resolution: Sector Houston/Galveston has received a class report attesting to the proper operational of the vessels'' steam valves.
Engineering › Sea-water System (primary cooling) › Pump
Issued 23 February 2009 Resolved
The packing gland in the vessel's general service pump/fire pump was leaking continuously. This adds additional water to the bilge. Pump must be serviced so to not leak prior to next U.S. port after sailing foreign to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 February 2009
Resolved 1 April 2010
Resolution: Vessel submitted class report attesting to the proper operation of the General Service/Fire Pump.
Navigation › Piloting/Steering › Gyro Compass
Issued 7 February 2007 Resolved
Gyro CPU CPB has a defect separating gyro control from repeater follow-up.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 8 February 2007
Resolution: Received tech report attesting to the proper operation of the gyro.
Construction/Loadline › Markings › Load Line Mark
Issued 1 July 2004 Resolved
Vessels plimsol markings are not marked using the symbols of the IAW International Conference on Loadlines, 1966 as Amended, Annex I Regulation 6, nor does the vessel's plimsol markings match the markings used on the International Loadline Certificate. NKK to address this issue.
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 2 August 2004
Resolution: Received class report from NKK satisfying requirement.
Engineering › Bilge Water Management System › Hose
Issued 1 July 2004 Resolved
Vessel has a temporary rubber band clamp patch on the discharge pipe for the OWS and on the suction pipe for the bilge pump.
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 2 August 2004
Resolution: Received class report from NKK satisfying requirement.
Navigation
Issued 8 July 1995 Resolved
CG BOARDING OFFICER OBSERVED THAT CHART 11370, 18th EDITION WAS NOT CURRENTLY CORRECTED. LAST CHART CORRECTION WAS 19/94, THE MOST RECENT CORRECTION IS 23/95. THIS ITEM IS REQUIERED FOR THE AREA TRANSITTED ON THE LOWER MISSISSIPPI RIVER FROM THE HEAD OF PASS TO MILE 175.
Condition: Unknown
Due 9 July 1995
Resolved 10 July 1995
Lifesaving
Issued 10 February 1995 Resolved
SOLAS III/31.7: LIFE BOUYS ON BRIDGE WINGS FOR SELF-ACTIVATING SMOKE MARKERS NOT 4 KG.
Condition: Unknown
Due 10 February 1995
Resolved 10 February 1995

Ownership record