← All vessels
SIOUX MAIDEN
SIOUX MAIDEN is a 1989 freight ship. The Coast Guard has recorded 25 inspections since 1991, most recently in March 2010, along with 7 deficiencies and 2 operational controls.
Records from 1991 to 2010. Most recent: inspection, 25 March 2010.
- Built
- 1989
- Last inspected
- 25 March 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8901133 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DYND
369567
Flag
PHILIPPINES
—
Maury page id
psix-369567
Inspections, by type
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it42248 - Dead Weight, Ton
48754 - Displacement, Ton
13807 - Regulatory (Subpart C or D), Net Ton
13807 - Convention (Subpart B), Net Ton
23270 - Regulatory (Subpart C or D), Gross Ton
23270 - Convention (Subpart B), Gross Ton
48754 - Displacement, Ton
13807 - Regulatory (Subpart C or D), Net Ton
13807 - Convention (Subpart B), Net Ton
23270 - Regulatory (Subpart C or D), Gross Ton
23270 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
25 March 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3702481
23 February 2009
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3416046
20 February 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3422227
7 February 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2868184
3 February 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2866568
19 January 2007
Type not recorded
No type recorded · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 2858507
17 July 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2715848
15 November 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2535290
14 November 2005
ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2533661
10 August 2004
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2161698
2 August 2004
PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2153696
1 July 2004
NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2116797
13 May 2004
Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2066865
11 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2065391
27 August 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1890215
21 October 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1690940
20 June 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 291146
14 April 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 289047
5 November 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 434594
4 November 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 422269
23 February 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 401270
3 May 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 390862
8 July 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 380423
10 February 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 375038
26 November 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 347229
Deficiency record · 7
Engineering › Steam System (main) › Piping
Issued 25 March 2010
Resolved
0999 All machinery and associated pipe fittings shall be installed and protected to minimize danger to persons onboard. 02 steam leaks are visible on 02 valves located on waste oil tank next to the incinerator. Solas 74 (2004 consolidated) chII-I, Reg 26.1
Engineering › Sea-water System (primary cooling) › Pump
Issued 23 February 2009
Resolved
The packing gland in the vessel's general service pump/fire pump was leaking continuously. This adds additional water to the bilge. Pump must be serviced so to not leak prior to next U.S. port after sailing foreign to the satisfaction of class.
Navigation › Piloting/Steering › Gyro Compass
Issued 7 February 2007
Resolved
Gyro CPU CPB has a defect separating gyro control from repeater follow-up.
Construction/Loadline › Markings › Load Line Mark
Issued 1 July 2004
Resolved
Vessels plimsol markings are not marked using the symbols of the IAW International Conference on Loadlines, 1966 as Amended, Annex I Regulation 6, nor does the vessel's plimsol markings match the markings used on the International Loadline Certificate. NKK to address this issue.
Engineering › Bilge Water Management System › Hose
Issued 1 July 2004
Resolved
Vessel has a temporary rubber band clamp patch on the discharge pipe for the OWS and on the suction pipe for the bilge pump.
Navigation
Issued 8 July 1995
Resolved
CG BOARDING OFFICER OBSERVED THAT CHART 11370, 18th EDITION WAS NOT CURRENTLY CORRECTED. LAST CHART CORRECTION WAS 19/94, THE MOST RECENT CORRECTION IS 23/95. THIS ITEM IS REQUIERED FOR THE AREA TRANSITTED ON THE LOWER MISSISSIPPI RIVER FROM THE HEAD OF PASS TO MILE 175.
Lifesaving
Issued 10 February 1995
Resolved
SOLAS III/31.7: LIFE BOUYS ON BRIDGE WINGS FOR SELF-ACTIVATING SMOKE MARKERS NOT 4 KG.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.