Records from 1992 to 2026. Most recent: inspection, 25 February 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 61
25 February 2026
Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8316698
19 February 2026
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8313061
30 April 2025
Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 8140752
28 January 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8069162
6 November 2024
Construction Oversight · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8031285
8 April 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7892023
12 March 2024
Drydock Exam · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7878013
21 November 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7828714
12 April 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7644678
9 March 2023
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648509
12 September 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7557739
29 March 2022
Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7420681
15 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412471
14 October 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7332491
27 July 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7275124
18 January 2021
DAPI Audit · COI Inspection · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7126313
13 January 2020
Administrative Inspection · Hull Examination · In-Service Inspection · Examination of Repairs · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6888149
25 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6840945
14 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6638237
21 March 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6375610
28 February 2018
Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6363629
2 March 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6100725
9 March 2016
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5830266
3 March 2016
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5826446
25 March 2010
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3694559
11 December 2009
Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3648704
30 March 2009
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3442678
1 April 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3167110
21 December 2007
Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3105268
19 April 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2906378
27 March 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2893464
22 March 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2890785
21 March 2006
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2564418
4 January 2006
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2556698
7 December 2005
Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2547496
4 October 2005
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2507821
9 March 2005
Deficiency Check · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2306885
20 December 2004
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2262463
31 March 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2005382
10 April 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1771436
24 March 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1758873
7 January 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1724579
20 May 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1624445
12 April 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1614123
10 April 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1494712
16 March 2001
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1453864
4 April 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1047947
8 February 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452625
22 April 1999
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1433473
26 February 1998
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1381169
12 May 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1100827
11 March 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424373
17 April 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1088089
11 March 1996
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383189
13 March 1995
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409259
14 March 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 854445
7 March 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165141
24 February 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1166685
12 July 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 6712
18 March 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1146001
24 March 1992
Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1258983
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2026
Resolved
Electrical equipment used in the following locations must be drip proof: machinery space... An outlet in the engine room was missing its drip proof cover. Vessel shall install new electrical cover.
46 CFR 183.210
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2026
Resolution: Pictures received from owner/operator, new cover installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 9 March 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire, hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condtion. A mooring line was degraded and causing a hazardous condition.
46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2026
Resolution: Vessel owner sent pictures of rectified mooring lines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2024
Resolved
Each life jacket must be marked with Type 1 retro reflective material. Marine Inspector found 09 adult life jackets with retro material in disrepair. Replace retro material.
Action required: 705 - Other - as specified
Resolved 7 June 2024
Resolution: New solas tape installed on life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 April 2023
Resolved
46 CFR 182.458(a)
Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps or outboard motor installations. A portable fuel container with diesel fuel oil was stored in the generator room. Portable fuel container was removed.
Action required: 10 - Deficiency Rectified
Resolved 12 April 2023
Resolution: Portable fuel container was removed from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 April 2023
Resolved
46 CFR 185.700(a)
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Hydrostatic release unit on inflatable life raft was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2023
Resolution: Received pictures of new hydrostatic release installed. See Documents.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 12 April 2023
Resolved
46 CFR 185.410(b)(1)
The monitoring device must ensure the wakefulness of the crew in the event that the watchman required is unresponsive. Installed watchman monitoring device does not alert on main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2023
Resolution: Received video of alerter sounding on bridge and in main deck area. See Documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2023
Resolved
46 CFR 183.05-50(b)(1)
Wiring joints and splices shall be mechanically secure and made in junction boxes. Found 3-wire joint taped together with electrical tape forward of the stbd engine and multiple dead end wires around stbd engine and port side steering compartment. Wires need to be mechanically secured in a junction box or completely removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
Resolution: Received pictures of wiring removed and junction boxes installed. See Documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 April 2023
Resolved
46 CFR 182.15-20(g)
Protective grating shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. Lagging on port side main engine was deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2023
Resolution: Received picture of renewed lagging. See Documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 April 2023
Resolved
46 CFR 176.800(a)
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Stbd shaft seal clamps were deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2023
Resolution: Received picture of replaced clamps. See Documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 February 2021
Resolved
Fuel shut off valves must be fitted in fuel supply lines. Ball valve handle broke when exercising valve in prescense of marine inspector. Replace ball valve/handle to satisfaction of MI.
46 CFR 182.455(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2021
Resolved 16 February 2021
Resolution: Vessel O/O provided objective evidence clearing def.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 February 2021
Resolved
Vessel must carry up to date charts of large enough scale to make safe navigation. Vessels current charts are out of date, replace with new.
46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2021
Resolved 18 February 2021
Resolution: Proper charts were obtained as per entry on activity #7126313.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 February 2021
Resolved
Vessel must carry approved first aid kit. Amonia inhalents were expired. Replace with new.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2021
Resolved 18 February 2021
Resolution: Ammonia inhalants that are still servicable were obtained as per entry on activity #7126313.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 October 2019
Resolved
Overnight accomodations for passengers must be fitted with an independent smoke detector. Noted no smoke detector in the salon area or for the seperate berthing areas. Provide smoke detectors for each space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2019
Resolution: Additional smoke detectors provided for required locations.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 25 October 2019
Resolved
A vessel with overnight accommodations must have the public address system operable from the operating station. Noted that the public address system was inoperable. Repair or replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2019
Resolution: Restored public address system and tested fully operable.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 March 2018
Resolved
Provide updated charts and Notice to Mariners.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 4 April 2018
Resolution: Verified complete during hull/ise inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 March 2018
Resolved
Provide annual servicing record for portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 4 April 2018
Resolution: Verified complete during hull/ise inspection.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 21 March 2018
Resolved
Remove alligator clips from batteries in engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 4 April 2018
Resolution: Verified complete during hull/ise inspection.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 March 2018
Resolved
Provide updated navigation publications.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 4 April 2018
Resolution: Verified complete during hull/ise inspection.
Operations/Management › Pollution › Other MARPOL Annex VI Deficiencies
Issued 21 March 2018
Resolved
Provide new MARPOL Annex V placard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 4 April 2018
Resolution: Verified complete during hull/ise inspection.
Engineering › Bilge Water Management System › Piping
Issued 21 December 2007
Resolved
Provide and install a positive shut off valve at all bilge overboard discharges for the electrical submersible pumps as per 46 CFR 182.520(e).
Due 21 January 2008
Resolved 7 January 2008
Resolution: Shut off valves were installed at the overboard discharges for the independent electrical bilge pumps.
Construction/Loadline › Hull › Bottom Plating
Issued 21 December 2007
Resolved
Provide and install a positive shut off valve at all bilge overboard discharges for the electrical submersible
pumps as per 46 CFR 182.520(e).
Make repairs to the fracture on the port side bow hull approx. three feet above the water line in the forward peak in what appears to be a layer of chop material and the shelf as per NVIC 8-87.
Due 21 January 2008
Resolved 7 January 2008
Resolution: Proper repairs were made to the fracture as per NVIC 8-87
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 21 December 2007
Resolved
Make repairs to the port propeller IWO the blade with the missing piece as per 46 CFR 176.800.
Due 21 January 2008
Resolved 7 January 2008
Documentation › Logs/Records › Logbook (official)
Issued 22 March 2007
Resolved
Provide a lifesaving equipment maintenance log as required by 46 CFR 185.702
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 27 March 2007
Resolution: Provided a lifesaving equipment maintenance log as required by 46 CFR 185.702.
Documentation › Logs/Records › Logbook (official)
Issued 22 March 2007
Resolved
Provide a bridge log as required by 46 CFR 185.702
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 27 March 2007
Resolution: Provided a bridge log as required by 46 CFR 185.702.
Communications › Public Address System › Loudspeaker
Issued 22 March 2007
Resolved
Provide a proper public address system as required by 46 CFR 184.610
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 27 March 2007
Resolution: Provided a proper public address system as required by 46 CFR 184.610.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 22 March 2007
Resolved
Properly stow the Inflatable Buoyant Apparatus to the satisfaction of the attending CG Marine Inspector as required by 46 CFR 180.130
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2007
Resolved 27 March 2007
Resolution: Properly stowed the Inflatable Buoyant Apparatus to the satisfaction of the attending CG Marine Inspector as required by 46 CFR 180.130.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 March 2007
Resolved
Provide proper first aid kit as required by 46 CFR 184.710
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 27 March 2007
Resolution: Provided proepr first aid kit as required by 46 CFR 184.710.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 March 2007
Resolved
Prove proper operation of engine shutdowns for fixed firefighting system to the satisfaction of the attending CG Marine Inspector as required by 46 CFR 181.410
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2007
Resolved 27 March 2007
Resolution: Proved proper operation of engine shutdowns for fixed fire fighting system to the satisfaction of the attending CG Marine Inspector as required by 46 CFR 181.410.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 March 2007
Resolved
Provide guards for all rotating machinery in accordance with 46 CFR 177.960
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 19 April 2007
Resolution: Provided guards for all rotating machinery in accordance with 46 CFR 177.960.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 March 2007
Resolved
Prove proper operation of light for lifejackets as required by 46 CFR 180.75
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 22 March 2007
Resolution: Replaced batteries in three lights
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 December 2005
Resolved
Repair or renew and prove operation of main engine raw water cooling sea valves.
Due 4 January 2006
Resolved 4 January 2006
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 December 2005
Resolved
Repair or renew and prove operation of live well pump raw water suction valve
Due 4 January 2006
Resolved 4 January 2006
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 28 December 2005
Resolved
Replace port shaft packing gland securing clamp.
Due 4 January 2006
Resolved 4 January 2006
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 28 December 2005
Resolved
Renew broken coupling bolt to port shaft.
Due 4 January 2006
Resolved 4 January 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 December 2005
Resolved
Repair or renew leaking exhaust piping to starboard main engine.
Due 4 January 2006
Resolved 4 January 2006
Construction/Loadline › Hull › Hull Plating
Issued 28 December 2005
Resolved
Repair cracking to FRP hull structure in way of bow thruster.
Due 4 January 2006
Resolved 4 January 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 29 March 2005
Resolved
Tighten rudder packing to prevent leaks in accordance with 46 CFR 182.610
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 5 April 2005
Resolution: Packing was tightened, stopping leak.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 March 2005
Resolved
Provide emergency lighting in passenger accommodation space in accordance with 46 CFR 183.432
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 5 April 2005
Resolution: Emergency lighting was provided in passenger accommodation space below main deck.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 March 2005
Resolved
Repair leak in wet exhaust in accordance with 46 CFR 182.430
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 5 April 2005
Resolution: Leak was repaired by tightening clamps on rubber hose portion of exhaust.
Stability › Watertight Integrity › General
Issued 29 March 2005
Resolved
Repair leak in live well drain, preventing water from draining in bilge in accordance with 46 CFR 176.830
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 5 May 2005
Resolution: Leak was repaired by replacing coupling on the drain.
Communications › Radio Communications › EPIRB
Issued 29 March 2005
Resolved
Repair or renew EPIRB antenna in accordance with 46 CFR 180.64
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 5 April 2005
Resolution: EPIRB''''s antennae was replaced as new.
Construction/Loadline › Hull › Side Shell
Issued 22 December 2004
Resolved
Repair delamination on port side bow in way of spray rail to the satisfaction of the attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 January 2005
Resolved 10 January 2005
Resolution: Delamination of port side bow repaired.
Construction/Loadline › Structures › Deck Plating
Issued 22 December 2004
Resolved
Renew/Repair fractured deck in rope locker to the satisfaction of the attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 January 2005
Resolved 10 January 2005
Resolution: Fractured deck in rope locker repaired.
Engineering › Sea-water System (primary cooling) › Valve
Issued 22 December 2004
Resolved
Remove unused sea valves in generator space to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 10 January 2005
Resolved 10 January 2005
Resolution: Unused sea valves were capped.
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 December 2004
Resolved
Renew/Repair fracture on longitudinal frame in way of strut mounting plate starboard side rudder compartment to the satisfaction of the attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 January 2005
Resolved 10 January 2005
Resolution: Fracture was repaired.
Documentation › Certificates/Documents
Issued 24 March 2003
Resolved
Provide current FCC Safety Certificate, as per 47 CFR Part 80. LEGACY COMPONENT DESC: FCC SSL
Due 23 April 2003
Resolved 10 April 2003
Resolution: Received copy of new FCC safety radio telephone certificate.
Documentation › Certificates/Documents
Issued 24 March 2003
Resolved
Provide current FCC Marine Radio Operator Permit, as per 47 CFR Part 80. LEGACY COMPONENT DESC: FCC SSL
Due 23 April 2003
Resolved 10 April 2003
Resolution: Received copy of new radio operators permit.
Lifesaving › Buoyant Apparatus
Issued 10 April 2002
Resolved
Replace Hydro Release for Inflatable Buoyant Apparatus no later than 20 April 2002. per 46 CFR 180.175.
LEGACY COMPONENT DESC: Hydro Release
Due 20 April 2002
Resolved 12 April 2002
Personnel › Certificates/Documents/Licenses
Issued 10 April 2002
Resolved
Provide valid CPR card for 50% of crew IAW NVIC 1-91 no later than 10 may 2002 LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Due 20 May 2002
Resolved 20 May 2002
Documentation
Issued 26 February 1998
Resolved
PROVIDE RED CROSS FIRST AID AND CPR TRAINING FOR 50% OF DECKHANDS IN ACCORDANCE WITH COAST GUARD NVIC 1-91 AND 46 CFR 176.808 (g).
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Lifesaving
Issued 26 February 1998
Resolved
PROPERLY REPAIR LIFE RING BUOY SEE COAST GUARD NVIC 2-63 FOR GUIDENCE.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Engineering
Issued 26 February 1998
Resolved
PROVE PROPER OPERATION OF BOTH THE PORT AND STARBOARD MAIN ENGINE OIL PRESSURE GAUGES LOCATED IN THE PILOTHOUSE IN ACCORDANCE WITH 46 CFR 182.20-5 (b).
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Engineering
Issued 11 March 1997
Resolved
PROVE PROPER OPERATION OF THE STBD MAIN ENGINE OIL PRESSURE GUAGE._x001C_ 46 CFR 182.410(b)
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Engineering
Issued 11 March 1997
Resolved
RENEW DETERIORATED FLEXIBLE HOSE FOR STBD MAIN ENGINE COOLING PUMP._x001C_ 46 CFR 182.720
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Construction/Loadline
Issued 11 March 1997
Resolved
REMOVE PVC PIPE THAT PENETRATES THE COLLISION BULKHEAD. ENSURE THE COLLISION BULKHEAD IS WATERTIGHT._x001C_ 46 CFR 170.310
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Documentation
Issued 11 March 1997
Resolved
PROVIDE ONBOARD VESSEL A VALID FCC STATION LICENSE,_x001C_ 46 CFR 80.15
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Engineering
Issued 11 March 1996
Resolved
PROPERLY LABEL EMERGENCY FUEL VALVES.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Documentation
Issued 11 March 1996
Resolved
PROVIDE EMPLOYEE ASSISTANCE PROGRAM THAT COMPLIES WITH 46 CFR 16.401.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Deck/Cargo
Issued 11 March 1996
Resolved
PROVIDE AND PROPERLY INSTALL THIMBLE ON ANCHOR LINE.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Lifesaving
Issued 11 March 1996
Resolved
PROVIDE DOCUMENTATION THAT EPRIB HYDRO RELEASE IS WITHIN EXPIRATION DATE ORRENEW RELEASE WITH CURRENT ACTIVATION DATE.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Documentation
Issued 11 March 1996
Resolved
PROVIDE UP TO DATE COPY OF THE RULES OF THE ROAD (72 COLREGS).
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 13 March 1995
Resolved
INSTALL METAL WIRE CLAMPS EVERY 18" ON OVERHEAD WIRE RUNS IN ENGINE ROOM
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Lifesaving
Issued 13 March 1995
Resolved
PERMANENTLY ATTACH WATER LIGHT WITH 6' LINE TO RING BUOY.
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Engineering
Issued 13 March 1995
Resolved
INSTALL BONDING WIRE ON FUEL FILL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Lifesaving
Issued 13 March 1995
Resolved
SERVICE HYDROSTATIC RELEASE ON LIFERAFT.
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Electrical
Issued 13 March 1995
Resolved
RENEW BONDING WIRES THROUGHOUT VESSEL
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Electrical
Issued 13 March 1995
Resolved
MAKE ALL ELECTRICAL CONNECTIONS PROPER THROUGHOUT VESSEL
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Engineering
Issued 7 March 1994
Resolved
REPLACE UNAPPROVED HOSE AND FITTINGS ON SUPPLY LINE TO 8 KW GENERATOR.
Condition: Unknown
Due 21 March 1994
Resolved 24 March 1994