Records from 1997 to 2004. Most recent: inspection, 3 February 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
3 February 2004
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2000055
7 August 2002
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1658684
24 July 2002
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1651449
16 April 2002
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1611272
12 April 2002
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1604286
5 December 2001
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1441945
23 August 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379174
31 May 2000
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384438
15 May 2000
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 817688
13 May 2000
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 817776
1 February 2000
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 814980
4 October 1999
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1465506
1 April 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 785072
4 January 1999
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 809482
24 November 1998
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375570
29 October 1998
Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1402729
10 September 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375556
28 August 1997
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 754445
26 August 1997
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 191690
29 April 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 808093
29 April 1997
Initial Certification · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407931
Construction/Loadline
Issued 5 December 2001
Resolved
MAKE PROPER BULKHEAD PENETRATION FOR CABLES PASSING BETWEEN ENGINE ROOM ANDLAZARETTE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2002
Resolved 12 April 2002
Resolution: Cable penetrations packed with waterproof material.
Electrical
Issued 5 December 2001
Resolved
REPLACE WIRE NUTS TO PUMP IN BILGE COMPARTMENT AT BASE OF LADDER WITH PROPER CONNECTIONS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 January 2002
Resolved 12 April 2002
Resolution: Sighted crimped connections in place of wire nuts.
Fire Fighting
Issued 5 December 2001
Resolved
PROVE PROPER OPERATION OF SMOKE DETECTOR IN CREW SPACE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2002
Resolved 12 April 2002
Resolution: Observed satisfactory test of smoke detector.
Engineering
Issued 5 December 2001
Resolved
PROVE EMERGENCY FUEL SHUT-OFF VALVES CLOSE FULLY. ITEM SHALL BE COMPLETED PRIOR TO TAKING PASSENGERS FOR HIRE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2002
Resolved 16 April 2002
Navigation › Piloting/Steering › Marine Charts
Issued 5 December 2001
Resolved
Navigation charts and publications not current iaw Local Notice to Mariners. New charts and pubs purchased and placed on board vsl prior to completion of inspection.
Due 5 December 2001
Resolved 5 December 2001
Resolution: Provided new charts and pubs.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 December 2001
Resolved
PFD stowage locations not labeled. Issued rqmt to properly label PFD lockers.
Due 5 December 2001
Resolved 5 December 2001
Resolution: Labeled PFD stowage locations.
Lifesaving › Buoyant Apparatus
Issued 5 December 2001
Resolved
Life floats were hard tied to guard rails with installed bights. Req'd operator to untie to allow life floats to be in a float free arrangement in the event of an emergency.
Due 5 December 2001
Resolved 5 December 2001
Resolution: Untied and made float free.
Electrical
Issued 5 December 2001
Resolved
Noted 2 battery boxes in E/R full of water. Issued rqmt to remove water.
Due 4 January 2002
Resolved 5 December 2001
Resolution: Removed water.
Engineering › Bilge Water Management System
Issued 5 December 2001
Resolved
Vessel operator unfamiliar with installed bilge pumping system and could not prove operation. Issued rqmt to prove proper operation of installed bilge pumping system. LEGACY COMPONENT DESC: Pump
Due 4 January 2002
Resolved 5 December 2001
Resolution: Proved proper operation of installed bilge pumping system
Documentation
Issued 4 October 1999
Resolved
UPDATE CERTIFICATE OF DOCUMENTATION TO SHOW VESSELS CORRECT LENGTH.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Deck/Cargo
Issued 24 November 1998
Resolved
Provide proof of weight test for installed crane.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Construction/Loadline
Issued 24 November 1998
Resolved
Install captive chain on lazzarette scuttle.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Electrical
Issued 24 November 1998
Resolved
Lock access door to live electrical panel.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Fire Fighting
Issued 24 November 1998
Resolved
Install fixed fire fighting system for engine room.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Construction/Loadline
Issued 24 November 1998
Resolved
Label forepeak bilge suction valve location.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Accommodation/Occupational Safety
Issued 24 November 1998
Resolved
Provide emergency lighting for emergency egress route from crew accomodation space.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Accommodation/Occupational Safety
Issued 24 November 1998
Resolved
Mark aft cargo deck "NO PASSANGERS ALLOWED".
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Lifesaving
Issued 24 November 1998
Resolved
Provide public address system.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Lifesaving
Issued 24 November 1998
Resolved
Provide 60' of line for resuce swimmers lifejacket.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Accommodation/Occupational Safety
Issued 24 November 1998
Resolved
Install positive locking device for MSD overboard valves.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Lifesaving
Issued 24 November 1998
Resolved
Provide 5 child size lifejackets.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Engineering
Issued 24 November 1998
Resolved
Install machinery guard over exposed accesory drive pump pulley on stbd engine.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Construction/Loadline
Issued 24 November 1998
Resolved
Install draft marks.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Lifesaving
Issued 24 November 1998
Resolved
Mark life jacket storage.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998