Records from 1992 to 2026. Most recent: inspection, 20 April 2026.
Inspection history · 106
20 April 2026
Administrative Inspection · Vessel Attendance
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8420711
8 April 2026
Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8325195
4 December 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8277823
13 January 2025
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8039778
30 April 2024
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7904263
10 April 2024
Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7892577
5 December 2023
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7820023
12 April 2023
Annual Inspection · In-Service Inspection · SIP Inspection/Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7642901
12 April 2022
Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7429944
2 December 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7360793
3 March 2021
Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7150534
4 December 2019
Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6870684
2 December 2019
COI Inspection · SIP Inspection/Audit · Administrative Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6852395
15 March 2019
Annual Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6643232
22 April 2018
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6397554
22 April 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6402671
10 April 2018
Administrative Inspection · Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6389178
27 November 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6319528
12 April 2017
Annual Inspection · SIP Inspection/Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6122326
20 October 2016
Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6026621
6 April 2016
Administrative Inspection · Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5847360
17 February 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5818468
4 December 2015
In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5775782
9 October 2015
Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5786120
24 October 2014
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5011520
13 December 2011
Examination of Repairs · Administrative Inspection · In-Service Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4209966
1 December 2011
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4231907
9 February 2010
MTSA Verification · DAPI Audit · COI Inspection · SIP Inspection/Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3677243
6 January 2010
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3659975
8 December 2009
Hull Examination · Examination of Repairs · Deficiency Check · Internal Structural Exam · In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3634325
30 March 2009
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3441642
4 March 2009
Administrative Inspection · DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3427797
13 August 2008
Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3297772
2 July 2008
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3256102
23 April 2008
Hull Examination · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3195361
4 March 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3180017
16 January 2008
Deficiency Check · SIP Initial Entry · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3131045
19 December 2007
Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3118357
16 October 2007
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3081334
17 March 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2890983
26 February 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2877944
7 March 2006
Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2630583
28 February 2005
COI Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2300811
2 January 2005
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2281398
26 February 2004
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2013289
20 February 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2010349
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977772
20 December 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2010012
12 December 2003
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2221925
7 October 2003
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1924321
17 March 2003
Administrative Inspection · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1743891
22 March 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1598123
4 March 2002
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1477664
12 December 2001
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1622199
22 May 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1064869
8 May 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1412282
28 February 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1437858
19 March 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 40980
3 March 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 61424
3 March 2000
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1427797
21 December 1999
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378886
28 October 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1129939
10 March 1999
Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 808395
8 March 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375681
21 December 1998
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381419
19 December 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 185094
13 December 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 104719
4 November 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 41644
24 February 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364603
16 December 1997
MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1408014
7 August 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 15710
9 July 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 43753
23 April 1997
Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1098172
4 March 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1402397
13 November 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1173586
17 October 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1155871
2 May 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 18126
24 April 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 164385
16 April 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 64500
4 April 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 88497
5 March 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355691
14 February 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 55697
8 February 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 10811
20 January 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 187440
12 January 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 7197
24 December 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754580
23 December 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 198577
21 December 1995
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383128
24 November 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 223907
21 November 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 83637
8 November 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 17009
19 April 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 175342
11 April 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1155691
7 March 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385399
4 January 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1457228
10 December 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 146136
10 December 1994
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1446153
16 March 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1446063
22 December 1993
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354573
14 June 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1150640
25 March 1993
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 834406
8 December 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356185
2 December 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 127101
11 August 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 953873
31 March 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 956401
28 February 1992
Inclining Experiment · Initial Certification · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1263582
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 2 December 2021
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The port MDE cooling water overboard piping, outboard of the overboard valve is wasted. Crop and renew.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 17 December 2021
Resolution: Discharge piping cropped and renewed.
Electrical › Electric Generation Source (service) › Generator
Issued 20 October 2016
Resolved
Repair or replace sea water discharge piping for #2 SSDG.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 29 November 2016
Resolution: New sea water piping replaced with copper nickel piping.
Electrical › Electric Generation Source (service) › Generator
Issued 20 October 2016
Resolved
Provide proper exhaust lagging for #2 SSDG.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 29 November 2016
Resolution: New lagging installed.
Electrical › Electric Generation Source (service) › Generator
Issued 20 October 2016
Resolved
Provide manufactureer information prooving that the engine L/O and J/W sensors have a self test function and do not need to be tested as part of the shut down test procedure.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 29 November 2016
Resolution: Literature provided.
Electrical › Electric Generation Source (service) › Generator
Issued 20 October 2016
Resolved
Provide a proper name plate for the #2SSDG with information reuired by 46 CFR 183.10-5 (Old T(L)).
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 29 November 2016
Resolution: Proper nameplates installed.
Documentation › Certificates/Documents › Stability Letter
Issued 17 November 2011
Resolved
Vsl restricted to carrying 1426 total persons IAW new AAWPP of 185 pounds per person. Vsl reps have appealed reduction to D14 and HQ but will abide by the required reduction until a final determination has been made.
Action required: 705 - Other - as specified
Due 1 December 2011
Resolved 11 December 2012
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 December 2009
Resolved
In line locker space, aft port side in way of 1st longitudinal frame, needle gun and gauge bottom IVO frame, provide gauging report.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 December 2009
Resolved
In sewage tank space, aft starboard side, needle gun and make available for inspection area of rust outboard of first longitudinal.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 8 December 2009
Resolved
Renew wasted bulkhead in scullery space on port side by ladderwell. Submit plans for repair.
Action required: 705 - Other - as specified
Resolved 18 December 2009
Construction/Loadline › Structures › Door
Issued 8 December 2009
Resolved
Renew wasted door frame by ladderwell in scullery space. Submit plans for repair.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Structures › Deck Plating
Issued 8 December 2009
Resolved
In scullery space, on port side by ladderwell, needle gun deck and lower bulkheads and make available for inspection.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Hull › Bracket
Issued 8 December 2009
Resolved
On top deck, renew starboard PA bracket.
Due 14 January 2010
Resolved 18 December 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 December 2009
Resolved
Renew electrical junction boxes in upper deck aft galley area, aft bulkhead.
Due 14 January 2010
Resolved 18 December 2009
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 December 2009
Resolved
In pumproom, starboard forward outboard of first longitudinal needle gun and make available for inspection identified area of scaling.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Penetrations › Gasket
Issued 8 December 2009
Resolved
Clean and renew gasket for watertight hatch in male head.
Action required: 705 - Other - as specified
Resolved 18 December 2009
Construction/Loadline › Penetrations › Gasket
Issued 8 December 2009
Resolved
Grind plus NDT or renew port steering compartment watertight hatch and renew gasket.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2009
Resolved
In engine room, port engine fwd, just aft of sea chest space, needle gun and gauge hull plating. Provide gauging report.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2009
Resolved
In engine room, aft of starboard engine below A/C unit needle gun and gauge hull plating. Provide gauging report.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2009
Resolved
In engine room, aft of sea chest, gauge hull plating and provide gauging report.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 December 2009
Resolved
Remove build-up in piping flange aft of sea chest in engine room.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 8 December 2009
Resolved
Make integral tank internals (fuel and flume tanks) available for inspection or provide gauging report for side / bottom plating portion of integral tanks.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 December 2009
Resolved
Grind and re-weld crack IVO port stern ramp.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Construction/Loadline › Structures › Door
Issued 2 April 2009
Resolved
Renew wasted watertight door frames at frame 36 port and starboard side as original.
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 15 April 2009
Operations/Management › Passenger Operations › Safety Orientation
Issued 2 April 2009
Resolved
Properly mark all decks with maximum number of passengers allowed in accordance with the Coast Guard approved emergency evacuation plan August 26, 1992.
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 10 June 2009
Resolution: Attended vessel and saw signage for maximum number of passengers.
Construction/Loadline › Structures › Scupper
Issued 2 April 2009
Resolved
Submit plans and calculations for modifications to vessel drainage for Coast Guard plan review and approval.
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 2 June 2009
Resolution: Received drainage calculations, however the Marine [name withheld] stated that because it is a flush deck vessel no calculations are required.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 30 March 2009
Resolved
Remove all combustible store items under bridge panel to prevent potential fire hazard.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 30 March 2009
Resolved
Renew or cap missing light and cover on starboard bridge wing.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Lifesaving › Buoyant Apparatus › Serviceable
Issued 30 March 2009
Resolved
Repair webbing strap on one identified buoyant apparatus.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Lifesaving › Buoyant Apparatus › Serviceable
Issued 30 March 2009
Resolved
Repair all cracks in buoyant apparatus and lifefloats with approved [name withheld] repair kit.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 March 2009
Resolved
Properly mark all emergency lighting - remove paint from covering all emergency lighting labels.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 6 April 2009
Resolution: Not required under Subchapter K or Subchapter J, is a legacy requirement from T-L which refers you to old Subchapter J. No longer applicable to vessel.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 March 2009
Resolved
Repair inoperable emergency light forward, starboard side, outside on second deck.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Engineering › Pressure Vessel › Relief Valve
Issued 30 March 2009
Resolved
Prove proper operation of pressure relief valve on starboard water heater in starboard CO2 room.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Fire Fighting › Combustible Materials › Insulation
Issued 30 March 2009
Resolved
Renew fire insulation for fire boundary at forward engine room bulkhead.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 March 2009
Resolved
Crop and renew corroded rail port side aft 10 feet forward of gangway.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 13 August 2008
Resolved
Catastrophic failure of the number 3 service generator
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 13 August 2008
Resolution: Installed new Caterpillar 2406C generator
Engineering › Generator (propulsion/auxiliary-electric) › Reverse Power Protection Relay Circuitry
Issued 13 August 2008
Resolved
Demonstrate reverse power protection relay using new generator.
Action required: 705 - Other - as specified
Resolved 2 September 2008
Resolution: Received copy of technician report that stated the completion of reverse relay tested completed on all 3 gen sets.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 August 2008
Resolved
Remove all storage from CO2 room
Action required: 705 - Other - as specified
Due 13 August 2008
Resolved 13 August 2008
Engineering › Bilge Water Management System › Piping
Issued 23 April 2008
Resolved
repair bilge suction pipe in bow thruster room near aft bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 May 2008
Resolution: New pipe was installed
Engineering › Bilge Water Management System › Piping
Issued 23 April 2008
Resolved
Repair bilge suction pipe in the in the fwd tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 May 2008
Resolution: New pipe was installed
Construction/Loadline › Hull › Transverse Frame
Issued 23 April 2008
Resolved
Crop and renew wasted frame located under sanitary pumps
Action required: 705 - Other - as specified
Resolved 2 May 2008
Resolution: Crop and renewed frame
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 February 2005
Resolved
Provide electrical drawings for micro commander and battery installation.
Due 29 March 2005
Resolved 8 March 2005
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 28 February 2005
Resolved
Provide elevator servicing report.
Due 29 March 2005
Resolved 9 March 2005
Fire Fighting › Structural - A Class Divisions
Issued 26 February 2004
Resolved
Ensure fire screen doors # 6, 9, 18 close and latch properly. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 15 March 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 February 2004
Resolved
Clean in way of all food & drink service and dispensing and storage areas.
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 15 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 26 February 2004
Resolved
Repair broken bulwark gusset located on main deck starboard just aft of #4 void vent. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 16 March 2004
Fire Fighting › Miscellaneous Items
Issued 26 February 2004
Resolved
Remove plastic trash containers from engine room. LEGACY COMPONENT DESC: Waste Receptacles
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 15 March 2004
Fire Fighting › Means of Escape
Issued 26 February 2004
Resolved
Clear pathway to engine room & scullery emergency escape scuttles.
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 15 March 2004
Documentation › Manifests/Lists
Issued 26 February 2004
Resolved
Replace torn station bill in the scullery. LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 15 March 2004
Pollution Prevention/Response › Prevention Equipment
Issued 26 February 2004
Resolved
Properly secure sewage overboard valve in accordance with 33 CFR 159.7(c). LEGACY COMPONENT DESC: Sewage System Valve
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 15 March 2004
Electrical › Electrical Distribution System (service)
Issued 26 February 2004
Resolved
Complete attached electrical worklist (17 items). LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 16 March 2004
Deck/Cargo › Holds/Tanks
Issued 4 March 2002
Resolved
Replace missing dogging arm to quick acting scuttle in CO2 room with engine room fixed fire extinguishing system in accordance with 46 CFR 46 171.121. LEGACY COMPONENT DESC: Hatch Cover
Due 22 March 2002
Resolved 22 March 2002
Resolution: Vessel operator replaced air to quick acting scutting in CO2 room.
Construction/Loadline › Structures
Issued 4 March 2002
Resolved
Repair holes in fire bulkhead between phot laboratory and bow thruster room in accordance with 46 CFR 115.802 LEGACY COMPONENT DESC: Fire Bulkhead
Due 22 March 2002
Resolved 22 March 2002
Resolution: Vessel operator repaired all holes in photo laboratory bulkhead.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 4 March 2002
Resolved
Provide proof of proper servicing of fixed fire entinguishing system in bow thruster room in accordance with 46 CFR 115.810. LEGACY COMPONENT DESC: FFE for Bow Thruster Room
Due 22 March 2002
Resolved 22 March 2002
Resolution: Vessel operator provided proof of fixed fire extinguishing system for the bow thruster room.
Electrical › Electrical Distribution System (service)
Issued 4 March 2002
Resolved
Repair deteriorated electrcial kick pipes to aft speakers located on upper deck.
Due 22 March 2002
Resolved 22 March 2002
Resolution: Vessel operator repaired the deteriorated electrical kick pipes.
Electrical › Electrical Distribution System (service)
Issued 4 March 2002
Resolved
Remove "semi-permanent" extension cords located in the following areas: 1) engineroom; 2) bow thruster room; 3) photo laboratory. LEGACY COMPONENT DESC: Extension Cords
Due 22 March 2002
Resolved 22 March 2002
Resolution: Vessel operator removed all "semi-permanent" extension cords.
Construction/Loadline › Penetrations
Issued 12 December 2001
Resolved
Remove and clean port thru hull screens. LEGACY COMPONENT DESC: Port Thru Holes
Due 13 December 2001
Resolved 18 December 2001
Resolution: Vessel operator removed and cleaned port thru hull screens.
Construction/Loadline › Penetrations
Issued 12 December 2001
Resolved
Repack cable packing passing through forward bulkhead, port side of centerline. LEGACY COMPONENT DESC: Packing
Due 13 December 2001
Resolved 18 December 2001
Resolution: Vessel operator repacked cable packing passing through forward bulkhead, port side of centerline.
Engineering › Fuel Oil Service System › Filter
Issued 12 December 2001
Resolved
Replace flame impingement bowls on fuel filters for main and ship service generator engine.
Due 13 December 2001
Resolved 18 December 2001
Resolution: Vessel operator replaced the flame impingement bowls on the fuel filters.
Lifesaving
Issued 8 May 2001
Resolved
Replace unservicable bouyant apparatus in accordance with 46 CFR 180.200(a)(2).
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Lifesaving
Issued 28 February 2001
Resolved
Repair(5) damaged buoyant apparatuses and replace (4) condemned buoyant apparatuses in accordance with 46 CFR 117.200. Passenger count is reduced by 154 persons until (4) condemned buoyant apparatuses are replaced with CGapproved lifefloats.
Condition: Unknown
Due 28 February 2001
Resolved 28 February 2001
Electrical
Issued 21 December 1995
Resolved
INSTALL GROUND DETECTION FOR THE SECONDARY SIDES OF THE POWER AND LIGHTING TRANSFORMER AND THE DINNER LOAD TRANSFORMER.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Electrical
Issued 21 December 1995
Resolved
PROVE PROPER OPERATION OF THE GENERATOR CIRCUIT BREAKERS IN AUTO MODE.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Engineering
Issued 21 December 1995
Resolved
DOUBLE CLAMP FLEX LINES IN THE MAIN DIESELS AND SS DIESEL GENERATORS COOLING LINES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Electrical
Issued 21 December 1995
Resolved
PROVE PARALLEL OPERATION BETWEEN NO.1 AND NO. 3 GENERATORS AND BETWEEN NO.2AND NO. 3 GENERATORS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Electrical
Issued 21 December 1995
Resolved
PROVE PROPER OPERATION OF THE REVERSE POWER RELAY FOR NO. 1 AND NO. 3 GENERATORS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Electrical
Issued 21 December 1995
Resolved
PROVE PROPER OPRATION OF THE VOLTAGE TRIM KNOBS IN THE SWITCHBOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Fire Fighting
Issued 7 March 1995
Resolved
POST OPERATING INSTRUCTIONS WHICH INCLUDE PROCEDURES FOR VENT AND FUEL TANKSHUTDOWN DEVICES AT MANUAL HALON DISCHARGE STATION.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
INSTALL STUFFING TUBES FOR RECENTLY INSTALLED BILGE ALARM CABLE AND RUDDER ANGLE INDICATOR CABLE AT ALL BULKHEAD AND DECK PENETRATIONS.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Electrical
Issued 7 March 1995
Resolved
INSTALL DRIP SHIELDS ON BOTH BATTERY CHARGERS LOCATED IN THE BOW THRUSTER ROOM.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
CLEAN AND REPAINT ALL FADED DRAFT MARKS.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995
Resolved
MAKE PROPER REPAIRS TO ALL DAMAGED AND TORN BUOYANT APPARATUSES.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
INSTALL MISSING A-60 INSULATION ON THE AFT BULKHEAD - CENTER AND PORT SIDE - AND IN THE OVERHEAD OF THE AFT PORT CORNER ALL LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Unknown
Issued 7 March 1995
Resolved
MAKE PERMANENT REPAIRS TO THE LEAKING 4" COOLING WATER DISCHARGE LINE FROM THE PORT MAIN ENGINE.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Engineering
Issued 7 March 1995
Resolved
INSTALL A PERSONNEL PROTECTIVE HEAT SHIELD AROUND JACKET WATER LINES FOR BOW THRUSTER ENGINE.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
PROVE PROPER OPERATION OF THE SUPPLY VENT FIRE DAMPENER LOCATED IN THE BOW THRUSTER ROOM.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995
Resolved
REPLACE BURNT LIGHT FILAMENT AND MAKE OPERABLE THE LIGHT FOR THE RESCUE BOAT LAUNCHING AREA.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Navigation
Issued 10 December 1994
Resolved
Provide a dedicated helmsman in addition to the master, until such time that the cause of the steering malfunction, i.e. turning hard left, experienced during routine testing, is positively determined and repetitivetesting does not duplicate malfunction.
Condition: Unknown
Due 10 December 1994
Resolved 10 December 1994
Documentation
Issued 22 December 1993
Resolved
SUBMIT PLANS FOR APPROVAL TO COAST GUARD HEADQUARTERS FOR ALL MODIFICATIONSMADE TO THE FWD AREA OF THE MAIN DECK.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Documentation
Issued 22 December 1993
Resolved
PROVIDE INFORMATION REGARDING THE ADMEASUREMENT OF THE VESSEL TO THE OCMI IN HONOLULU, INCLUDE CALCULATIONS MADE, AND COPIES OF ANY CERTIFICATES OR DOCUMENTS REGARDING THE ADMEASUREMENT OF THE VESSEL.
Condition: Unknown
Due 27 January 1994
Resolved 18 February 1994
Engineering
Issued 25 March 1993
Resolved
REPAIR PORT ENGINE OIL PRESSURE GAUGE ON BRIDGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 April 1993
Resolved 23 April 1993
Engineering
Issued 25 March 1993
Resolved
INSTALL GUARDS ON BOTH MAIN ENGINE AT AFT END OF TURBO CHARGERS
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Engineering
Issued 25 March 1993
Resolved
TEST PROPER OPERATION OF J/W ALARMS ON BOTH MAIN ENGINES AND BOTH GENERATORS BY TESTING THE SENSOR.
Condition: Unknown
Due 25 April 1993
Resolved 23 April 1993
Construction/Loadline
Issued 31 March 1992
Resolved
REPLACE THE SECONDARY CENTRIFUGAL FIRE/BILGE PUMP IN THE ENGINE ROOM WITH ASELF-PRIMING PUMP CAPABLE OF TAKING SUCTION FROM EACH COMPARTMENT CONNECTEDTO THE BILGE MANIFOLD.
Condition: Unknown
Due 31 May 1992
Resolved 1 July 1992
Lifesaving
Issued 31 March 1992
Resolved
REPLACE THE 9 FOOT RESCUE BOAT WITH A MORE SUITABLE RESCUE BOAT MEETING THESIZE REQUIREMENTS OF 46 CFR 160.056. (I.E. SUITABLE FOR AT LEAST THREE PERSONS, BETWEEN 11 AND 14 FEET IN LENGTH, AND WEIGH LESS THAN 225 POUNDS)
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Lifesaving
Issued 31 March 1992
Resolved
INSTALL ON THE 04 DECK A SUITABLE METHOD OF LAUNCHING THE BUOYANT APPARATUSINTO THE WATER FROM EITHER SIDE OF THE VESSEL, AND INSTALL A SAFETY RAIL ALONG THE PERIMETER OF THE AFTER QUARTER OF THE DECK WITH AT LEAST 1 COURSE36 INCHES HIGH.
Condition: Unknown
Due 30 April 1992
Resolved 1 July 1992
Lifesaving
Issued 28 February 1992
Resolved
PROVIDE PROPER STOWAGE AND LABELING OF LIFEJACKETS ON LOUNGE DECK.,_x001C_
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Unknown
Issued 28 February 1992
Resolved
PROVE PROPER OPERATION OF BOTH ELEVATORS PRIOR TO USE BY PASSENGERS/CREW.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992