WENDELLA LTD.

WENDELLA LTD. is a 1992 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1992, most recently in March 2026, along with 46 deficiencies and 2 casualty investigations between 2011 and 2013.

Records from 1992 to 2026. Most recent: inspection, 10 March 2026.

Built
1992
Last inspected
10 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBD7147
369774
Flag
UNITED STATES
367152790
Maury page id
psix-369774

Inspections, by type

…with no type recorded2
Years with a record 30 calendar years (1992–2026)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 20.2 ft × 8.1 ft
Registered tonnagegross 71 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROS ENTRPRISES · LOREAUVILLE, LA, UNITED STATES · built 1992
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
56 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBD7147MMSI 367152790 · active · compulsorily equipped · granted 22 November 2016, expires 14 February 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

10 March 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8323624
1 August 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8200135
21 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8140466
21 March 2025 Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8097678
5 March 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7874213
2 May 2023 Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7678740
24 May 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7442916
22 September 2021 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7318371
19 May 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7201369
21 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7043840
27 August 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6796173
18 March 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6645009
12 June 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6444839
5 April 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6385561
29 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6381064
15 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6267504
22 June 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6195533
19 May 2017 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6149979
10 May 2017 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6147747
26 September 2016 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6010001
18 May 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5880552
4 April 2016 Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5847557
29 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5824057
17 October 2014 Annual Inspection · In-Service Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5064384
15 October 2014 In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5005807
20 June 2014 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4894840
20 April 2009 MTSA Verification · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3454714
16 April 2009 Deadweight Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3454642
23 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3220336
16 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3181513
3 December 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3108774
28 March 2007 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2888064
19 January 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2858531
10 January 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2853686
28 March 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2611343
25 March 2005 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2315438
15 July 2004 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2134304
21 June 2004 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2088787
1 April 2004 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2026155
12 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963437
2 April 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1764410
2 October 2002 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1680114
12 March 2002 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1493036
4 April 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1405161
7 April 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1047367
7 April 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1454646
6 August 1998 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1131052
4 August 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 13398
8 April 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1404553
10 October 1997 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1438652
11 April 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1465324
15 April 1996 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1355821
7 July 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 872002
7 April 1995 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1467904
14 July 1994 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 869487
13 April 1994 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1370813
23 June 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1153728
14 April 1993 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1149412
25 March 1993 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 838541
13 July 1992 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1260331
15 May 1992 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1256704
23 April 1992 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264740
21 April 1992 Hull Examination · Plan Review "T" Boat · Initial Certification · Inclining Experiment · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1263499

Deficiency record · 46

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2021 Resolved
Electrical outlet on port side of wheel in pilot house is broken around ground prong. Replace outlet.
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Outlet replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 May 2021 Resolved
Thru WTB penetrations in multiple compartments are not watertight. Make thru WTB penetrations watertight.
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: WTB penetrations were made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2021 Resolved
SWBD needs non-conducting mats or grating in the front of the area.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Non-conductive matting was placed in front of SWBD.
Engineering › Lubricating Oil Service System › Gauge
Issued 19 May 2017 Resolved
repair or replace oil pressure guage on Starboard Gen
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 22 June 2017
Resolution: Gauge has been replaced
Electrical › Electric Generation Source (service) › Switch
Issued 19 May 2017 Resolved
install new knob on A/c control in lower main cabin
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 22 June 2017
Resolution: New knob has been installed
Engineering › Fuel Oil Service System › Gauge
Issued 19 May 2017 Resolved
Install new face plate on fuel level indicator in pilot house
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 22 June 2017
Resolution: new face plate was installed
Engineering › Electric Propulsion System › Circuit Board
Issued 19 May 2017 Resolved
repair alarm fault on starboard MDE
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 22 June 2017
Resolution: JD rep came out and repaired fault on Engine alarm
Personnel › Training › Familiarization Training
Issued 18 May 2016 Resolved
Provide and prove proper training of crewman Rafal Wilk and [name withheld] including MOB, Fire and Flooding per emergency procedures and company policy in accordance with 46 CFR 185.420, 185.512
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2016
Resolved 19 May 2016
Resolution: conducted drills and basic emergency procedures.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 17 April 2009 Resolved
Ensure distribution panel is fully enclosed per 46 CFR 120.330.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 4 May 2009
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 16 April 2008 Resolved
Renew raw water hose on stbd main engine IAW 46 CFR 119.700 &710.
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 23 May 2008
Resolution: Raw water hose on stbd main engine replaced.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 16 April 2008 Resolved
Renew raw water hose clamp on gen #1 IAW 46 CFR 119.410.
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 23 May 2008
Resolution: Raw water hose clamp on gen #1 renewed.
Engineering › Bilge Water Management System › Hose
Issued 16 April 2008 Resolved
Renew raw water hose clamp on bilge suction in engine space IAW 46 CFR 119.410.
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 23 May 2008
Resolution: Raw water hose clamp on bilge suction in engine space renewed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2008 Resolved
Secure loose wires on stbd engine IAW 46 CFR 120.200.
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 23 May 2008
Resolution: Loose wires on stbd engine secured.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 16 April 2008 Resolved
Ensure proper labeling on breaker box in engine space IAW 46 CFR 120
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 16 April 2008
Resolution: Properly labeled breaker box.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 April 2008 Resolved
Renew outlet in pilot house, port side.
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 23 May 2008
Resolution: Outlet in pilot house, port side renewed.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 April 2008 Resolved
Provide bilge alarm in #2 space IAW 46 CFR 119
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2008
Resolved 16 April 2008
Resolution: Audible alarm for #2 space was not in operation, audible and visual alarms were repaired.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 March 2007 Resolved
Provide 3 Child size PFD's IAW 46 CFR 117.70 & 71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 30 March 2007
Engineering › Bilge Water Management System › Not Operational
Issued 28 March 2007 Resolved
Power driven bilge pump will not suck from forepeak.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2007
Resolution: Pipe was fractured due to freezing water. Welded new pipe section.
Engineering › Bilge Water Management System › Pump
Issued 28 March 2007 Resolved
Wiring to electric bilge in machinery room pump chaffed where they pass through the deck plates.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 30 March 2007
Electrical › Electric Generation Source (service) › Generator
Issued 28 March 2007 Resolved
Find and repair source of water leaking onto the #1SSG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 30 March 2007
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 March 2007 Resolved
Reinstall missing E-60 structural fire protection insulation over the #1SSG.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 23 April 2007
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 28 March 2007 Resolved
Remove or reconnect disconnected sensor wires on the #2SSG
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 30 March 2007
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 28 March 2006 Resolved
Replace or remove heat detectors that do not work and are not required by the regs.
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 3 December 2007
Resolution: 5-02-06 detectors removed from space
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 28 March 2006 Resolved
Provide approved plans from MSC for New Generator and provide documentation on gen specs. 46 CFR 115..700
Action required: 705 - Other - as specified
Due 1 March 2007
Resolved 3 December 2007
Resolution: Received approval letter from MSC for the generator install.
Construction/Loadline › Structures › Superstructure
Issued 28 March 2006 Resolved
Repair or replace broken windows in pilot house and cabin.
Action required: 705 - Other - as specified
Due 31 January 2007
Resolved 28 March 2007
Resolution: Corrected IAW Regulation.
Engineering › Pressure Vessel › Relief Valve
Issued 19 May 2005 Resolved
Replace or renew air receiver safety valve located port side next to the wheelhouse.
Action required: 705 - Other - as specified
Due 18 June 2005
Resolved 14 July 2005
Resolution: Received purchase order of newly installed safety relief valve, all sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 March 2005 Resolved
Ensure all lifejacket containers are properly labeled with correct number of lifejackets.
Action required: 705 - Other - as specified
Due 25 April 2005
Resolved 19 May 2005
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 25 March 2005 Resolved
Prove proper operation of new Rudder Angle Indicator.
Action required: 705 - Other - as specified
Due 25 April 2005
Resolved 19 May 2005
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 25 March 2005 Resolved
Prove proper operation of port and stbd jacket water temp gauges in pilothouse.
Action required: 705 - Other - as specified
Due 25 April 2005
Resolved 19 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 March 2005 Resolved
Properly secure all wire runs on overhead w/ metal runners.
Action required: 705 - Other - as specified
Due 25 April 2005
Resolved 19 May 2005
Engineering › Bilge Water Management System › Piping
Issued 25 March 2005 Resolved
Remove PVC elbow, ivo of port engine, for aux pump going into the bilge manifold.
Action required: 705 - Other - as specified
Due 25 April 2005
Resolved 19 May 2005
Lifesaving
Issued 8 April 1998 Resolved
PROVIDE 02 ADDITIONAL LIFE JACKETS (EXTENDED SIZE) TO BRING VESSEL'S COMPLIMENT TO FULL CAPACETY OF 222.
Condition: Unknown
Due 22 April 1998
Resolved 20 May 1998
Navigation
Issued 8 April 1998 Resolved
REPAIR CONNECTOR ARM FROM RUDDER TO REPEATBACK TRANSMITTER IN STEERING SPACE.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Lifesaving
Issued 8 April 1998 Resolved
RENEW 02 RING BUOYS.
Condition: Unknown
Due 22 April 1998
Resolved 20 May 1998
Electrical
Issued 11 April 1997 Resolved
Repair and properly install, or remove from vessel, all wiring and sensors for inoperative installed security system.
Condition: Unknown
Due 30 April 1997
Resolved 23 July 1997
Engineering
Issued 11 April 1997 Resolved
Prove proper operation of starboard main engine lube oil pressure gauge in pilothouse.
Condition: Unknown
Due 30 April 1997
Resolved 23 July 1997
Lifesaving
Issued 11 April 1997 Resolved
Provide five (5) additional adult-size life preservers to attain the required amount of 224. Until this requirement is met, the vessel's maximum allowable passenger capacity is reduced to 219.
Condition: Unknown
Due 30 April 1997
Resolved 17 July 1997
Electrical
Issued 11 April 1997 Resolved
Properly block and brace all battery installations on the vessel.
Condition: Unknown
Due 30 April 1997
Resolved 23 July 1997
Lifesaving
Issued 7 April 1995 Resolved
Mark bow, life preserver stowage locker with the number and size of the life preservers stowed therein.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Navigation
Issued 7 April 1995 Resolved
Provide a current magnetic compass deviation correction table for the vessel.
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Electrical
Issued 7 April 1995 Resolved
Install junction boxes for deck hatch alarm connections. Installation, materiel and workmanship are to be to the satisfaction of [name withheld], IL.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Lifesaving
Issued 7 April 1995 Resolved
Conduct manoverboard, abandon ship, fire and anchor drills to the satisfaction of [name withheld], IL prior to carrying passengers for the season, and in no case later than 21APR95.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Navigation
Issued 7 April 1995 Resolved
Provide current navigation chart/s for area of operation.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Electrical
Issued 13 April 1994 Resolved
REPLACE PLASTIC TIE WRAPS IN ENGINE ROOMM WITH METAL CLAMPS.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Electrical
Issued 13 April 1994 Resolved
PROPERLY CLEAN ALL BATTERY TERMINALS OF CORROSION.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Documentation
Issued 21 April 1992 Resolved
PROVIDE ON BOARD VALID FCC RADIOTELEPHONEY SAFETY CERTIFICATE.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992

Casualty record · 2

16 June 2011Routine · role: Involved in a Marine Casualty · activity 4089242
5 September 2013Routine · role: Involved in a Marine Casualty · activity 4796144
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.