Records from 1991 to 2002. Most recent: inspection, 8 June 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
8 June 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1636067
18 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 428736
4 November 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 409715
17 June 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753781
16 June 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 195225
2 June 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404059
30 May 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404407
6 April 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 401899
29 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1191857
8 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 381434
19 February 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 349188
28 November 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1258939
Deck/Cargo
Issued 18 May 1999
Resolved
MAKE PERMANENT REPAIRS TO IGS GENERATOR FEED WATERLINE, TO SATISFACTION OF CLASS (LR).
Condition: Unknown
Due 15 July 1999
Resolved 8 June 2002
Deck/Cargo
Issued 6 April 1997
Resolved
RENEW VIEWING COVERS (FACES) FOR CARGO PIPELINE PRESSURE GAUGES WITHIN THE CARGO PUMP ROOM.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Deck/Cargo
Issued 6 April 1997
Resolved
RENEW FLAME SCREENS ON FUEL OIL VENTS. FLAMES SCREENS INSPECTED WERE CONTAMINATED WITH OIL.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Documentation
Issued 6 April 1997
Resolved
PROVIDE MEDICAL/HEALTH CERTIFICATES FOR "ALL" CREW MEMBERS.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Documentation
Issued 6 April 1997
Resolved
UPDATE OIL TRANSFER PROCEDURES; ESPECAILLY INFORMATION ON MAINTAINING VESSEL MOORINGS, EMERGENCY SHUTDOWN, TOPPING OFF TANKS, AND ENSURING VALVESARE CLOSED AT COMPLETION OF TRANSFER.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Navigation
Issued 6 April 1997
Resolved
ENSURE AUTO-PILOT ALARMS ARE INSTALLED, APPROVED, AND MEET THE REQUIREMENTSOF 33 C.F.R. 157.440.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Lifesaving
Issued 6 April 1997
Resolved
ENSURE PORT & STARBOARD LIFEBOATS ARE CAPABLE OF BEING RELEASED/LOWERED USING PRIMARY RELEASE MECHANISM WITHIN LIFE BOAT.
Condition: Unknown
Due 8 April 1997
Resolved 12 April 1997
Electrical
Issued 6 April 1997
Resolved
REMOVE DEAD END WIRING IN CARGO PUMP ROOM OR END IN EXPLOSION PROOF JUNCTION BOX.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Accommodation/Occupational Safety
Issued 6 April 1997
Resolved
RENEW CLOSURES TO ACCOMMODATION SPACES; NOT ALL DOORS CLOSE PROPERLY.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Documentation
Issued 28 November 1991
Resolved
PROVIDE MANEUVERING INFORMATION STATEMENT, AS PER 33 CFR 164.35 (g)(6) BY NEXT US PORT.
Condition: Unknown
Due 28 November 1991
Resolved 28 November 1991
Documentation
Issued 28 November 1991
Resolved
PROVIDE FOR REVIEW OIL TRANSFER PROCEDURE THAT MEETS THE REQUIREMENTS OF 33CFR 155.750.
Condition: Unknown
Due 28 November 1991
Resolved 28 November 1991
Navigation
Issued 28 November 1991
Resolved
REPAIR AND PROVE OPERATION OF LORAN C PRIOR TO ENTRY INTO NEXT US PORT.
Condition: Unknown
Due 28 November 1991
Resolved 28 November 1991
Deck/Cargo
Issued 28 November 1991
Resolved
REPAIR AND PROVE OPERATION OF THE #2 IGS BLOWERS PRIOR TO TRANSFER OF CARGOIN NEXT US PORT.
Condition: Unknown
Due 28 November 1991
Resolved 28 November 1991