SANDRA TAPIAS is a 1991 tank ship. The Coast Guard has recorded 12 inspections since 1991, most recently in June 2002, along with 13 deficiencies.

Records from 1991 to 2002. Most recent: inspection, 8 June 2002.

Built
1991
Last inspected
8 June 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8910110 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
369928
Flag
LIBERIA
—
Maury page id
psix-369928

Inspections, by type

…with no type recorded9
Years with a record 6 calendar years (1991–2002)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it147253 - Dead Weight, Ton
45309 - Convention (Subpart B), Net Ton
77387 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 12

8 June 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1636067
18 May 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 428736
4 November 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 409715
17 June 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753781
16 June 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 195225
2 June 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404059
30 May 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404407
6 April 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 401899
29 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1191857
8 August 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 381434
19 February 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 349188
28 November 1991 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1258939

Deficiency record · 13

Deck/Cargo
Issued 18 May 1999 Resolved
MAKE PERMANENT REPAIRS TO IGS GENERATOR FEED WATERLINE, TO SATISFACTION OF CLASS (LR).
Condition: Unknown
Due 15 July 1999
Resolved 8 June 2002
Deck/Cargo
Issued 6 April 1997 Resolved
RENEW VIEWING COVERS (FACES) FOR CARGO PIPELINE PRESSURE GAUGES WITHIN THE CARGO PUMP ROOM.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Deck/Cargo
Issued 6 April 1997 Resolved
RENEW FLAME SCREENS ON FUEL OIL VENTS. FLAMES SCREENS INSPECTED WERE CONTAMINATED WITH OIL.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Documentation
Issued 6 April 1997 Resolved
PROVIDE MEDICAL/HEALTH CERTIFICATES FOR "ALL" CREW MEMBERS.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Documentation
Issued 6 April 1997 Resolved
UPDATE OIL TRANSFER PROCEDURES; ESPECAILLY INFORMATION ON MAINTAINING VESSEL MOORINGS, EMERGENCY SHUTDOWN, TOPPING OFF TANKS, AND ENSURING VALVESARE CLOSED AT COMPLETION OF TRANSFER.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Navigation
Issued 6 April 1997 Resolved
ENSURE AUTO-PILOT ALARMS ARE INSTALLED, APPROVED, AND MEET THE REQUIREMENTSOF 33 C.F.R. 157.440.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Lifesaving
Issued 6 April 1997 Resolved
ENSURE PORT & STARBOARD LIFEBOATS ARE CAPABLE OF BEING RELEASED/LOWERED USING PRIMARY RELEASE MECHANISM WITHIN LIFE BOAT.
Condition: Unknown
Due 8 April 1997
Resolved 12 April 1997
Electrical
Issued 6 April 1997 Resolved
REMOVE DEAD END WIRING IN CARGO PUMP ROOM OR END IN EXPLOSION PROOF JUNCTION BOX.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Accommodation/Occupational Safety
Issued 6 April 1997 Resolved
RENEW CLOSURES TO ACCOMMODATION SPACES; NOT ALL DOORS CLOSE PROPERLY.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Documentation
Issued 28 November 1991 Resolved
PROVIDE MANEUVERING INFORMATION STATEMENT, AS PER 33 CFR 164.35 (g)(6) BY NEXT US PORT.
Condition: Unknown
Due 28 November 1991
Resolved 28 November 1991
Documentation
Issued 28 November 1991 Resolved
PROVIDE FOR REVIEW OIL TRANSFER PROCEDURE THAT MEETS THE REQUIREMENTS OF 33CFR 155.750.
Condition: Unknown
Due 28 November 1991
Resolved 28 November 1991
Navigation
Issued 28 November 1991 Resolved
REPAIR AND PROVE OPERATION OF LORAN C PRIOR TO ENTRY INTO NEXT US PORT.
Condition: Unknown
Due 28 November 1991
Resolved 28 November 1991
Deck/Cargo
Issued 28 November 1991 Resolved
REPAIR AND PROVE OPERATION OF THE #2 IGS BLOWERS PRIOR TO TRANSFER OF CARGOIN NEXT US PORT.
Condition: Unknown
Due 28 November 1991
Resolved 28 November 1991