Records from 1992 to 2018. Most recent: inspection, 29 January 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
29 January 2018
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6345122
24 May 2012
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4319456
15 December 2009
Deficiency Check · DAPI Audit
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3653016
24 March 2009
Drydock Exam · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3438803
22 June 2007
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2969893
22 March 2007
COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2892498
10 May 2006
Periodic Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2645290
3 March 2006
Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2596376
10 May 2005
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2353506
1 April 2004
Periodic Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2034974
1 September 2003
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1957112
11 March 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1492620
26 February 2002
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1487624
8 June 2001
Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1366407
22 March 2001
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1373398
20 March 2001
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1382163
16 March 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1048183
10 March 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365623
31 August 1999
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 781452
23 July 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1103739
7 July 1999
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1375821
15 June 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 809945
12 May 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1131695
9 May 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 795103
3 May 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 801909
12 March 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365102
28 January 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1124086
14 July 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 794598
7 May 1998
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1124999
8 August 1997
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1117764
23 May 1997
Hull Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1109080
22 November 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1179610
12 March 1996
Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 876745
8 May 1995
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1357146
25 July 1994
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1176514
22 March 1994
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 857756
5 November 1993
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 838344
24 September 1993
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1147985
21 December 1992
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1136328
16 July 1992
Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1270212
Engineering › Steering Gear System › Rudder Stock
Issued 24 May 2012
Resolved
Install bolt to secure emergency tiller coupling to rudder stock.
Due 24 June 2012
Resolved 25 May 2012
Resolution: New bolt installed.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 24 May 2012
Resolved
Repair cross threaded elbow on dripless packing cooling line.
Due 24 June 2012
Resolved 24 May 2012
Resolution: New elbow installed.
Documentation › Certificates/Documents › FCC SSL
Issued 22 March 2007
Resolved
Provide valid FCC Safety certificate.
Due 6 April 2007
Resolved 16 April 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 March 2007
Resolved
Replace stern light.
Due 6 April 2007
Resolved 5 April 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 May 2005
Resolved
Provide logbook with drills and EPIRB test.
Due 24 May 2005
Resolved 25 May 2005
Lifesaving › Lifefloat › Lifeline
Issued 10 May 2005
Resolved
Install detachable clip on life ring.
Due 24 May 2005
Resolved 25 May 2005
Documentation › Logs/Records › Drug Test Records
Issued 10 May 2005
Resolved
Provide proof of enrollment in drug testing program.
Due 24 May 2005
Resolved 10 May 2005
Accommodation/Occupational Safety › Medical/First Aid
Issued 1 April 2004
Resolved
Place an approved first aid kit on board the vessel. LEGACY COMPONENT DESC: Medicine Chest
Due 8 April 2004
Resolved 9 April 2004
Fire Fighting
Issued 1 April 2004
Resolved
Place a sufficient length of line on fire buckets.
Due 8 April 2004
Resolved 9 April 2004
Stability
Issued 1 April 2004
Resolved
Prove proper operation of automatic bilge pump indicator light for aft bilge pump.
Due 8 April 2004
Resolved 9 April 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 1 April 2004
Resolved
Have fixed firefighting system annually serviced.
Due 8 April 2004
Resolved 8 April 2004
Lifesaving › Lifebuoys
Issued 26 February 2002
Resolved
Attach retro reflective tape to vessel ring buoy. Tape to be positioned at 90-degree quadrants.
Due 10 March 2002
Resolved 11 March 2002
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System
Issued 26 February 2002
Resolved
Replace plastic plug on the bottom of RACOR filter flame impingement bowl with metallic plug. LEGACY COMPONENT DESC: Filter/Strainer
Due 10 March 2002
Resolved 11 March 2002
Resolution: Metallic plug in place.
Fire Fighting
Issued 9 May 1999
Resolved
Provide proof of purchase of a manual & automatic actuated fixed fire extinguishing system meeting the full requirements of 46 CFR 181.400. Vessel COI will be revoked, and vessel limited to not more than 6 passengers, without proof of purchase by 28MAY99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Lifesaving
Issued 12 March 1999
Resolved
Replace/repair reflective marking and re-mark vessel's name on life jackets._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Engineering
Issued 12 March 1999
Resolved
Install a shut-off valve on the fuel line as close to the engine as possible.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Construction/Loadline
Issued 12 March 1999
Resolved
Install a positive shut-off valve on all bilge discharge lines. Valve to be located as close to the hull as possible._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Construction/Loadline
Issued 12 March 1999
Resolved
Install an automatic bilge pump indicator at/near the vessel control station. The indicator must provide a visual indication of bilge pump operation.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Fire Fighting
Issued 12 March 1999
Resolved
Install a fixed firefighting system in accordance with 46 CFR 181.420 System to have have both automatic and manual pull operation._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Fire Fighting
Issued 12 March 1999
Resolved
Place on board one (1) B-I type portable fire extiguisher.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Lifesaving
Issued 12 March 1999
Resolved
Repair/replace lifefloat due to weathering. Stencil/mark lifefloat with vessel's name._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Lifesaving
Issued 7 May 1998
Resolved
Update and post the vessel's Emergency Instructions to reflect the current changes as iterated in 46 CFR 185.510.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 7 May 1998
Resolved
Replace the existing life float weak link with a 11-20 capacity weak link approved by the Coast Guard.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Engineering
Issued 7 May 1998
Resolved
Prove the proper operation of the existing remote fuel shut-off system.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 7 May 1998
Resolved
Provide a lanyard/chain or equivalent mechanism to prevent the cockpit and stern hatch from being removed from the vessel.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 7 May 1998
Resolved
Install a valve handle for the engine compartment bilge suction valve on the bilge piping manifold.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Fire Fighting
Issued 7 May 1998
Resolved
Provide a means for manual actuation of the installed pre-engineered fixed fire fighting system in the engine space as required in 46 CFR 181.420.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Navigation
Issued 7 May 1998
Resolved
Prove the operation of the starboard running light as required in the COLREGS.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 23 May 1997
Resolved
Remove "old" Guam registration numbers from vessel bow.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Lifesaving
Issued 23 May 1997
Resolved
Post lifejacket donning placard per 46 CFR 184.516.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Lifesaving
Issued 23 May 1997
Resolved
Install paddles and waterlight on life float.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Navigation
Issued 23 May 1997
Resolved
Post Emergency Broadcast Instructions (46CFR 184.510) near radio.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Construction/Loadline
Issued 8 May 1995
Resolved
GRIND OFF ALL JEL-COAT BELOW THE WATER LINE AND THE FIRST LAYER OF MATT TO THE 1ST LAYER OF ROVING TO REMOVE THE BLISTERS AND ALL OF THE DELAMINATED GLASS, ALLOW TIME FOR THE MOISTURE TO SURFACE AND BLOOM ON THE GLASS, AND THEN GRIND BACK ANY BLOOMED AREAS TO GOOD LAMINATES. ANY AREAS THAT HAVE _x001C_
Condition: Unknown
Due 8 May 1995
Resolved 8 May 1995