Records from 1994 to 2004. Most recent: inspection, 2 December 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
2 December 2004
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2251885
26 August 2003
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1887323
12 February 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1743386
16 January 2003
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1731204
24 October 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1696940
10 July 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1644485
28 May 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1621585
31 May 2001
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1445811
21 May 2001
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1068420
30 September 2000
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1068419
1 August 2000
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1053502
16 December 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 811806
8 November 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375970
2 September 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1388606
27 July 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375446
23 October 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777610
5 September 1997
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1407779
1 June 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 701675
31 May 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 127329
Stability › Watertight Integrity
Issued 26 August 2003
Resolved
Make aft engine room bulkhead watertight (MTWTB). Correct stuffing/penetration for wire run IWO electrical panel.
Condition: Improper Installation
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Electrical › Electric Supply System (service)
Issued 26 August 2003
Resolved
Replace missing battery tray IWO port MDE. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Electrical › Lighting (service)
Issued 26 August 2003
Resolved
Renew missing light covers on engineroom fixtures. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 26 August 2003
Resolved
Renew the delay relay for the automatic fixed fire fighting system. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Documentation › Certificates/Documents
Issued 26 August 2003
Resolved
Provide a current Document fo the vessel. The one onboard is expired. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2003
Resolution: Done.
Lifesaving › Lifejacket/PFD (General)
Issued 26 August 2003
Resolved
Post instructions for child lifejackets. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Lifesaving › Inflatable Liferafts
Issued 26 August 2003
Resolved
Stow liferafts in a float free arrangement. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2003
Resolution: Done.
Documentation › Logs/Records
Issued 26 August 2003
Resolved
Conduct crew training and drills IAW 46 CFR 185.520 and 185.524 and make log entries recording same. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Operations/Management › Drug and Alcohol Testing
Issued 26 August 2003
Resolved
Provide evidence of current drug and alcohol program to include MIS report for this year. LEGACY COMPONENT DESC: MIS Submission
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Navigation › Piloting/Steering
Issued 26 August 2003
Resolved
Provide a current deviation table for the steering compass. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Communications › Internal Communications System
Issued 26 August 2003
Resolved
Make repairs to public address system. System was INOP on the upper deck.
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Construction/Loadline › Hull
Issued 16 January 2003
Resolved
Repair indicated at areas marked by CG inspector. LEGACY COMPONENT DESC: Bottom
Condition: Damaged By Earlier Event
Due 31 January 2003
Resolved 12 February 2003
Engineering › Feedwater/Condensate Water System
Issued 16 January 2003
Resolved
Remove white hose on port side sea chest for A/C raw water supply, and install hose that meets SAE J1942 standard. LEGACY COMPONENT DESC: Drain
Condition: Improper Installation
Due 31 January 2003
Resolved 12 February 2003
Electrical › Electrical Distribution System (service)
Issued 28 May 2002
Resolved
Install approved electrical mat on deck at main switch board. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Improper/Lack of Maintenance
Due 28 June 2002
Resolved 10 July 2002
Electrical › Electric Supply System (service)
Issued 28 May 2002
Resolved
Install generator interlock or prove installation is iaw 46CFR111.12(f). LEGACY COMPONENT DESC: Reverse Current Protection
Condition: Improper Installation
Due 28 June 2002
Resolved 10 July 2002
Operations/Management › Drills/Instruction
Issued 28 May 2002
Resolved
Provide instructions for proper operation of engine room fixed fire fighting system. LEGACY COMPONENT DESC: Fire
Condition: Unknown
Due 28 June 2002
Resolved 10 July 2002
Documentation › Manuals/Policy Documentation
Issued 28 May 2002
Resolved
Provide instruction for operation of emergency fire pump. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Due 28 June 2002
Resolved 24 October 2002
Construction/Loadline › Markings
Issued 28 May 2002
Resolved
On or before next hull examination, install/paint load line marks IAW 46CFR185.602. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Unknown
Due 28 June 2002
Resolved 21 February 2003
Construction/Loadline › Structures
Issued 28 May 2002
Resolved
Replace gasket on steering compartment Hatch. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Due 30 June 2002
Resolved 10 July 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 28 May 2002
Resolved
Demonstrate proper operation of the fixed halon system IAW 46CFR181-400(c). LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2002
Resolved 24 October 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 28 May 2002
Resolved
Demonstrate proper operation of main engine shut down upon activation of fixed halon system. LEGACY COMPONENT DESC: Operating Controls
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2002
Resolved 10 July 2002
Construction/Loadline › Structures
Issued 28 May 2002
Resolved
Repair scuttle on bow to ensure it secures properly. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 24 October 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 May 2002
Resolved
Elevate CO2 bottle in battery compartment, to no more than 80 degrees. LEGACY COMPONENT DESC: Tanks
Condition: Improper Installation
Due 1 June 2002
Resolved 24 October 2002
Lifesaving › Lifebuoys
Issued 28 May 2002
Resolved
Attach 60ft of floatable line that is UV resistant to the ring life buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper Installation
Due 1 June 2002
Resolved 10 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 28 May 2002
Resolved
Install new retroreflective tape on 15 adult and 1 child PFD's. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 10 July 2002
Fire Fighting
Issued 31 May 2001
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 June 2001
Resolved 20 June 2001
Fire Fighting
Issued 8 November 1999
Resolved
Prior to 16 Dec 99, comply with the Fixed Fire Extinguishing System requirements of 46CFR181.400 and demonstrate operation of same.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Navigation
Issued 2 September 1998
Resolved
PRIOR TO 09SEP98, PROVID "UP TO DATE" AREA CHARTS, CURRENT TABLES, LIGHT LIST AND COAST PILOT.
Condition: Unknown
Due 9 September 1998
Resolved 11 September 1998
Fire Fighting
Issued 2 September 1998
Resolved
PRIOR TO 09SEP98, PROVIDE FIRE EXTINGUISHER LOCATION LABELS FOR B-II EXTINGUISHER IN MAIN SALON AND B-II EXTINGUISHER IN PASSENGER ACCOMMODATIONSPACE FWD.
Condition: Unknown
Due 9 September 1998
Resolved 11 September 1998
Lifesaving
Issued 2 September 1998
Resolved
PRIOR TO 09SEP98, REMOVE COMBUSTABLE MATERIALS FROM LAZARETTE/ELECTRICAL PANEL ROOM.
Condition: Unknown
Due 9 September 1998
Resolved 11 September 1998
Accommodation/Occupational Safety
Issued 2 September 1998
Resolved
PRIOR TO 09SEP98, PROVIDE LABELS FOR UPPER DECK AND LADDERS TO READ "MAXIMUM CAPACITY 40 PASSENGERS", VISE 60 PASSENGERS, AS PER STABILITY LETTER.
Condition: Unknown
Due 9 September 1998
Resolved 11 September 1998
Documentation
Issued 5 September 1997
Resolved
COMPLY WITH AND POST STABILITY LETTER.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997