MAURY USCG vessel records Sign in
← All vessels

ENTREPRENEUR

ENTREPRENEUR is a 1992 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 1994, most recently in December 2004, along with 32 deficiencies.

Records from 1994 to 2004. Most recent: inspection, 2 December 2004.

Built
1992
Last inspected
2 December 2004
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAY5169
370162
Flag
UNITED STATES
366728270 (licence lapsed)
Maury page id
psix-370162

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (1994–2004)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)101.7 ft × 24.2 ft × 10.5 ft
Registered tonnagegross 190 / net 57
ITC dimensions (L × B × D)101.7 ft × 24.2 ft × 10.5 ft
ITC tonnagegross 190 / net 57
BuilderCHRISTENSEN MOTOR YACHT · VANCOUVER, WA, UNITED STATES · built 1992
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 21 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it190 - Convention (Subpart B), Gross Ton
57 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX2034MMSI 366728270 · expired · compulsorily equipped · granted 9 January 1997, cancelled 17 March 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

2 December 2004 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2251885
26 August 2003 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1887323
12 February 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1743386
16 January 2003 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1731204
24 October 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1696940
10 July 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1644485
28 May 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1621585
31 May 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1445811
21 May 2001 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1068420
30 September 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1068419
1 August 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1053502
16 December 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 811806
8 November 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375970
2 September 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1388606
27 July 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375446
23 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777610
5 September 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1407779
1 June 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 701675
31 May 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 127329

Deficiency record · 32

Stability › Watertight Integrity
Issued 26 August 2003 Resolved
Make aft engine room bulkhead watertight (MTWTB). Correct stuffing/penetration for wire run IWO electrical panel.
Condition: Improper Installation
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Electrical › Electric Supply System (service)
Issued 26 August 2003 Resolved
Replace missing battery tray IWO port MDE. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Electrical › Lighting (service)
Issued 26 August 2003 Resolved
Renew missing light covers on engineroom fixtures. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 26 August 2003 Resolved
Renew the delay relay for the automatic fixed fire fighting system. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Documentation › Certificates/Documents
Issued 26 August 2003 Resolved
Provide a current Document fo the vessel. The one onboard is expired. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2003
Resolution: Done.
Lifesaving › Lifejacket/PFD (General)
Issued 26 August 2003 Resolved
Post instructions for child lifejackets. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Lifesaving › Inflatable Liferafts
Issued 26 August 2003 Resolved
Stow liferafts in a float free arrangement. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2003
Resolution: Done.
Documentation › Logs/Records
Issued 26 August 2003 Resolved
Conduct crew training and drills IAW 46 CFR 185.520 and 185.524 and make log entries recording same. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Operations/Management › Drug and Alcohol Testing
Issued 26 August 2003 Resolved
Provide evidence of current drug and alcohol program to include MIS report for this year. LEGACY COMPONENT DESC: MIS Submission
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Navigation › Piloting/Steering
Issued 26 August 2003 Resolved
Provide a current deviation table for the steering compass. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Communications › Internal Communications System
Issued 26 August 2003 Resolved
Make repairs to public address system. System was INOP on the upper deck.
Condition: Improper/Lack of Maintenance
Due 26 September 2003
Resolved 25 September 2003
Resolution: Done.
Construction/Loadline › Hull
Issued 16 January 2003 Resolved
Repair indicated at areas marked by CG inspector. LEGACY COMPONENT DESC: Bottom
Condition: Damaged By Earlier Event
Due 31 January 2003
Resolved 12 February 2003
Engineering › Feedwater/Condensate Water System
Issued 16 January 2003 Resolved
Remove white hose on port side sea chest for A/C raw water supply, and install hose that meets SAE J1942 standard. LEGACY COMPONENT DESC: Drain
Condition: Improper Installation
Due 31 January 2003
Resolved 12 February 2003
Electrical › Electrical Distribution System (service)
Issued 28 May 2002 Resolved
Install approved electrical mat on deck at main switch board. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Improper/Lack of Maintenance
Due 28 June 2002
Resolved 10 July 2002
Electrical › Electric Supply System (service)
Issued 28 May 2002 Resolved
Install generator interlock or prove installation is iaw 46CFR111.12(f). LEGACY COMPONENT DESC: Reverse Current Protection
Condition: Improper Installation
Due 28 June 2002
Resolved 10 July 2002
Operations/Management › Drills/Instruction
Issued 28 May 2002 Resolved
Provide instructions for proper operation of engine room fixed fire fighting system. LEGACY COMPONENT DESC: Fire
Condition: Unknown
Due 28 June 2002
Resolved 10 July 2002
Documentation › Manuals/Policy Documentation
Issued 28 May 2002 Resolved
Provide instruction for operation of emergency fire pump. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Due 28 June 2002
Resolved 24 October 2002
Construction/Loadline › Markings
Issued 28 May 2002 Resolved
On or before next hull examination, install/paint load line marks IAW 46CFR185.602. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Unknown
Due 28 June 2002
Resolved 21 February 2003
Construction/Loadline › Structures
Issued 28 May 2002 Resolved
Replace gasket on steering compartment Hatch. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Due 30 June 2002
Resolved 10 July 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 28 May 2002 Resolved
Demonstrate proper operation of the fixed halon system IAW 46CFR181-400(c). LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2002
Resolved 24 October 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 28 May 2002 Resolved
Demonstrate proper operation of main engine shut down upon activation of fixed halon system. LEGACY COMPONENT DESC: Operating Controls
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2002
Resolved 10 July 2002
Construction/Loadline › Structures
Issued 28 May 2002 Resolved
Repair scuttle on bow to ensure it secures properly. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 24 October 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 May 2002 Resolved
Elevate CO2 bottle in battery compartment, to no more than 80 degrees. LEGACY COMPONENT DESC: Tanks
Condition: Improper Installation
Due 1 June 2002
Resolved 24 October 2002
Lifesaving › Lifebuoys
Issued 28 May 2002 Resolved
Attach 60ft of floatable line that is UV resistant to the ring life buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper Installation
Due 1 June 2002
Resolved 10 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 28 May 2002 Resolved
Install new retroreflective tape on 15 adult and 1 child PFD's. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 10 July 2002
Fire Fighting
Issued 31 May 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 June 2001
Resolved 20 June 2001
Fire Fighting
Issued 8 November 1999 Resolved
Prior to 16 Dec 99, comply with the Fixed Fire Extinguishing System requirements of 46CFR181.400 and demonstrate operation of same.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Navigation
Issued 2 September 1998 Resolved
PRIOR TO 09SEP98, PROVID "UP TO DATE" AREA CHARTS, CURRENT TABLES, LIGHT LIST AND COAST PILOT.
Condition: Unknown
Due 9 September 1998
Resolved 11 September 1998
Fire Fighting
Issued 2 September 1998 Resolved
PRIOR TO 09SEP98, PROVIDE FIRE EXTINGUISHER LOCATION LABELS FOR B-II EXTINGUISHER IN MAIN SALON AND B-II EXTINGUISHER IN PASSENGER ACCOMMODATIONSPACE FWD.
Condition: Unknown
Due 9 September 1998
Resolved 11 September 1998
Lifesaving
Issued 2 September 1998 Resolved
PRIOR TO 09SEP98, REMOVE COMBUSTABLE MATERIALS FROM LAZARETTE/ELECTRICAL PANEL ROOM.
Condition: Unknown
Due 9 September 1998
Resolved 11 September 1998
Accommodation/Occupational Safety
Issued 2 September 1998 Resolved
PRIOR TO 09SEP98, PROVIDE LABELS FOR UPPER DECK AND LADDERS TO READ "MAXIMUM CAPACITY 40 PASSENGERS", VISE 60 PASSENGERS, AS PER STABILITY LETTER.
Condition: Unknown
Due 9 September 1998
Resolved 11 September 1998
Documentation
Issued 5 September 1997 Resolved
COMPLY WITH AND POST STABILITY LETTER.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997