← All vessels
NORTHUMBERLAND
NORTHUMBERLAND is a 1990 tank ship. The Coast Guard has recorded 30 inspections since 1992, most recently in February 2004, along with 5 deficiencies and 4 operational controls.
Records from 1992 to 2004. Most recent: inspection, 10 February 2004.
- Built
- 1990
- Last inspected
- 10 February 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8813075 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
MAYM9
370166
Flag
UNITED KINGDOM
—
Maury page id
psix-370166
Inspections, by type
…with no type recorded22
Years with a record
11 calendar years (1992–2004)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it16137 - Dead Weight, Ton
22842 - Displacement, Ton
11822 - Convention (Subpart B), Gross Ton
3751 - Convention (Subpart B), Net Ton
22842 - Displacement, Ton
11822 - Convention (Subpart B), Gross Ton
3751 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
10 February 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2004087
30 August 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1894336
25 August 2003
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1887989
1 August 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1655198
2 April 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1600490
1 March 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1490504
15 October 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 295151
15 October 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 772312
16 July 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 487547
14 October 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 283146
14 October 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 823322
3 March 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 465410
3 March 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 511357
28 February 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275280
4 November 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 434463
12 October 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433787
20 February 1999
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 425637
11 October 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 421332
11 October 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 801114
17 July 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 405773
10 April 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 402270
10 April 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1110167
18 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392423
4 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 381362
16 May 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 378420
16 May 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1235392
22 June 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 514916
19 May 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 350838
5 March 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 492591
8 January 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1266541
Deficiency record · 5
Deck/Cargo
Issued 12 October 1999
Resolved
Eliminate minor leakage in way of gas tight seals at Motor and Compressor Room bulkhead to the satisfaction of the Classification Society. Provide cognizant OCMI with satisfactory surveyor's report.
Electrical
Issued 12 October 1999
Resolved
Replace intrinsically safe lighting in way of #1 Starboard Cargo Tank with explosion proof fixtures to the satisfaction of the Classification Society.Provide cognizant OCMI with satisfactory surveyor's report.
Accommodation/Occupational Safety
Issued 12 October 1999
Resolved
Properly mark MSD piping, eliminate all inaccurate labeling (directions andarrows).
Electrical
Issued 12 October 1999
Resolved
Renew electrical ground strap on Electrical Motor Room ventilation blower to the satisfaction of the Classification Society. Provide cognizant OCMI with satisfactory surveyor's report.
Deck/Cargo
Issued 11 October 1998
Resolved
Gas detection cabinet sampling point sensor for gas detection is inoperable. Accomodation space vent sampling point is not readily accessible. Prove proper operation of these sampling points (#1 gas cabinet and #6 air conditioner)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.