MAURY USCG vessel records
← All vessels

MARGARITAVILLE AT SEA PARADISE

Built
1991
Last inspected
25 July 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 July 2026
…with no type recorded6
Operational controls 1 with no removal date recorded
Years with a record 9 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8716502
370316
Flag
BAHAMAS, THE
Maury page id
psix-370316

Documentation record

Tonnage as PSIX records it53015 - Convention (Subpart B), Gross Ton
53015 - Regulatory (Subpart C or D), Gross Ton
26445 - Convention (Subpart B), Net Ton
29741 - Displacement, Ton
26445 - Regulatory (Subpart C or D), Net Ton
8032 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 44 inspections, each with its date, unit and type; 86 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 44

25 July 2026 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8449374
10 July 2026 PSC A · Administrative Inspection · COC-CVE Annual
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8434382
23 February 2026 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8314313
9 February 2026 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8307907
9 July 2025 COC-CVE Annual · PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8179415
15 January 2025 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8063247
5 November 2024 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8030004
7 October 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8031365
10 July 2024 COC-CVE Annual · PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7953987
16 January 2024 PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7847659
9 August 2023 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7764288
9 July 2023 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7739183
19 April 2023 PSC A · COC-CVE Quarterly
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7671445
6 April 2023 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7663801
17 March 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7652521
19 January 2023 PSC A · COC-CVE Quarterly
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7624039
15 December 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7609556
25 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7583291
25 October 2022 PSC A · COC-CVE Quarterly
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7583295
18 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579699
12 September 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7557015
8 September 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7554173
13 July 2022 Deficiency Check · COC-CVE Annual
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7503351
15 June 2022 In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7478490
18 January 2022 COC-CVE Quarterly · PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7381740
4 October 2021 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7326112
8 September 2021 Deficiency Check · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7306644
25 August 2021 ISPS Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7296361
12 July 2021 Deficiency Check · PSC A · Administrative Inspection · COC-CVE Annual
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7221453
7 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6936530
13 February 2020 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6908783
13 February 2020 In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6912482
5 February 2020 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6903477
16 October 2019 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6834603
16 July 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6762784
15 May 2019 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6685064
17 April 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6664683
17 April 2019 In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6664992
15 April 2019 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6660293
9 April 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6659790
19 October 2018 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6564847
15 October 2018 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6561215
23 April 2018 Security Breach
Type not classified · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6397795
10 April 2018 ISPS II Exam · COC-CVE Initial · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6390883

Deficiency record · 86

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 July 2026 Resolved
Where the contents and use of a space are such that there is a doubt to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Combustible materials were stored in a Category 10 A/C room on starboard side, deck 7, MVZ 5. 74SOLAS 81 Ammed. II-2/26.2.2 15c
Action required: 15 - Rectify deficiencies by next port
Resolved 10 July 2026
Resolution: A/C room was cleared before examination team departed the vessel.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 10 July 2026 Resolved
The public address system shall be clearly audible above the ambient noise in all spaces, and shall be provided with an override function controlled from one location on the navigation bridge. The public address system was not audible above the ambient noise in the arcade, deck 8, MVZ 5. 74SOLAS(20) III/6.5.2 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2026
Resolved 25 July 2026
Resolution: RINA submitted a report stating that the vessel has installed an electrical interruption device which shuts down the power to the arcade when the PA is in use.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2026 Resolved
All waste-receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Waste-receptacles located on the open deck are made of combustible materials.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2026
Resolved 23 February 2026
Resolution: Vessel provided Class attestation to the waste receptacles being replased with non-combustible materials.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 15 January 2025 Resolved
An International Load Line Certificate shall be isued to every ship which has been surveyed and marked in accordance with the present Convention. PSCO observed ILLC issued by RINA did not match Plimsoll markings currently showing BV.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2025
Resolution: MSU Lake Worth recieved Class survey report recifying deficiency to show Load Lines have been updated to RINA classification society.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 July 2024 Resolved
74 SOLAS 01 II-2/41-2.4.7 The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not mor than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Section of Low Location Lighting was not working on Deck 10 in way of cabins near the aft stairway stbd side.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 July 2024
Resolved 10 July 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 July 2024 Resolved
74 SOLAS 20 II-2/14.1.1 Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Section Valve 6-8 leaking from one of the cut off valves to the system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2024
Resolved 10 July 2024
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 July 2024 Resolved
74 SOLAS 81 Amend II-2/26.1 The minimum for integrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. Combustible materials were found stored in a Category 10 electrical locker, changing the space categorization and use.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2024
Resolved 10 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 July 2024 Resolved
74 SOLAS 01 II-2/41-2.4.1 Hinged fire doors in stairway enclosures, main vertical zone bulkheads and galley boundaries which are normally kept open shall be self-closing and be capable of release from a central control station and form a position at the door. Fire doors 1-154 and dirty linen stores did not fully close after being opened from the fully open position.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 July 2024
Resolved 10 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 January 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Deck 03, category 3 space is being used to sort and store garbage in combustible containers outside of the category 12 garbage room. 74 SOLAS 81 Amend II-2/26.2.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2024
Resolution: All items removed from space.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 January 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat #6 has a hole in the starboard side hull near the entrance. 74 SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2024
Resolution: Repaired while CG onboard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 January 2024 Resolved
The speed of door closure shall, if necessary, be controlled so as to prevent undo danger to personnel. Fire doors 6-007 and 3-014 are closing so fast (02 seconds) that could cause injury to anyone using the door.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 January 2024
Resolution: Doors adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 July 2023 Resolved
74 SOLAS (81 amend) II-2/ 23.1 The hull, superstructures, structural bulkheads, decks, and deckhouses shall be constructed of steel or other equivalent material. For the purposes of applying the definition of steel or other equivalent material as given in regulation 3.7 the "applicable fire exposure" shall be according to the integrity and insulation standards given in the tables of regulations 26 and 27. Penetrations of the A0 boundaries were found in the radar mast and on the fire screen doorframes exiting the aft crew stairway on deck 10.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2023
Resolved 9 August 2023
Resolution: Class report recieved attesting to the repair of the penetrations.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 July 2023 Resolved
74 SOLAS (81 amend) II-2/ 36.1.1 An automatic sprinkler... of an approved type, complying with the provisions of regulation 12 and so installed and arranged as to protect such spaces. PSCO observed deck 7 port side arcade room had gaming equipment blocking sprinkler heads from full coverage in the areas being protected.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 July 2023
Resolved 10 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 July 2023 Resolved
74 SOLAS (81 amend) II-2/ 30.2 The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke anf flame, as fas as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and doorframes shall be constructed of steel or other equivalent material. Fire screen door 1152 and multiple fire doors located on deck 3 did not close.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2023
Resolved 10 July 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 July 2023 Resolved
74 SOLAS (2001 amend) II-2/ 41-2.4.7 The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators places not more than 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. Means of escape signage posted in passenger corridor (deck 7, starboard side) did not match the emergency escape plan and did not properly enable passengers to identify the best escape route.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 July 2023
Resolved 10 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 April 2023 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire doors 09034, 05001, and 07002 are not in proper working order - 74 SOLAS 2020 II-2/14.2.1.2 - 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 April 2023
Resolution: Cleared by USCG COC / PSCO Team
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2023 Resolved
All electrical apparatuses shall be so constructed and so installed as not to cause injury in the normal manner. PSCO observed an unauthorized electrical outlet installed in aft port casino storage closet; outlet was installed in such a manner that did not prevent electrical shock - 74 SOLAS 04 II-1/45 - 10c
Action required: 10 - Deficiency Rectified
Resolved 19 April 2023
Resolution: Cleared by USCG COC / PSCO Team
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 January 2023 Resolved
Fire Fighting systems and appliances shall be kept in good working order and readily available for immediate use. Doors 6/188, 3/210, and 3/214 do not properly seal not maintaining the fire division - 74 SOLAS 2020 II-2/14.2.1.2 - 10c
Action required: 10 - Deficiency Rectified
Resolved 19 January 2023
Resolution: Cleared by COC / PSCO Team
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 19 January 2023 Resolved
Every ship of 12 meters or more shall display placards which notify the crew of the discharge requirements. Garbage placard was not present in vessels garbage room - MARPOL 2017 Annex 5 Reg 10.1.1 - 10c
Action required: 10 - Deficiency Rectified
Resolved 19 January 2023
Resolution: Cleared by COC / PSCO Team
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 October 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During the abandon ship drill Lifeboat #4 engine was unable to start as per the requirements - 74 SOLAS 97 III/20 - 10c / 11101
Action required: 10 - Deficiency Rectified
Due 25 October 2022
Resolved 25 October 2022
Resolution: Lifeboat #4 was successfully ran and completed operational test observed by PSCO.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 October 2022 Resolved
Emergency lighting required by regulations II-1/42 and III/11.5, the means of escape including stairways and exits shall be marked, at all points of the escape route including angles and intersections, by lighting or photoluminescent strip indicators. Aft deck crew category 2 stairs on deck 8 leading from the galley did not have low location lighting on the landing with the doors either opened or closed - 74 SOLAS 01 II-2/41-2 - 10c - 07120
Action required: 10 - Deficiency Rectified
Due 15 November 2022
Resolved 25 October 2022
Resolution: Vessels crew installed low location strips in aft deck crew category 2 stairs on deck 8 leading from the galley.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 13 July 2022 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the company. In meeting these requirements the company should ensure that: procedures are established and maintained for identifying any training which may be required and conducted for all personnel concerned; inspections are held at appropriate intervals, any non-conformity is reported with its possible cause, if known, and appropriate corrective action is taken; procedures are established for the implementation of corrective action, including measures intended to prevent reoccurrence. Due to the objective evidence in the below deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. PSCOs collected objective evidence that the vessel was not identifying non-conformities following the inspection and reporting requirements of its SMS, the vessel was not taking steps to prevent the reoccurrence of non-conformities, and that the vessel was not properly maintaining the procedures for properly conducting crew training. An external audit conducted by the Flag is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port - 74 SOLAS (2014 Cons) Ch IX/3.1 ISM Code Part A Reg 6.5, 10.1, 9.2 - 30abc
Action required: 30 - Ship detained
Resolved 14 July 2022
Resolution: MSD Lake Worth received ISM audit from the recognized organization Bureau Veritas and has accepted the Audit to clear the above deficiency. See attached audit in documents tab.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 July 2022 Resolved
Every crewmember with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCOs did not witness sufficient action by the crew to extinguish/ prevent the growth of a fire during the fire drill and did not satisfactorily witness the simulated abandonment of the vessel. Crew did not adequately perform the positions to which they were assigned to abandon the vessel - 74 SOLAS (2020 Cons.)III/19.2.1 - 30abc
Action required: 30 - Ship detained
Resolved 14 July 2022
Resolution: MSD Lake Worth received ISM audit from Bureau Veritas and successfully witnessed a satisfactory fire/abandon/passenger evacuation drill. Verification training of personnel with emergency duties was verified with emergency duties was verified. Def Cleared
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 July 2022 Resolved
Every crewmember with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCOs were unable to adequately ascertain the proper answers from crew when conducting questioning regarding the stairway guides roles/ required knowledge per ships procedures and the crew roles during abandon ship. This, along with being unable to properly conduct fire and abandon ship drills, points to a breakdown in the vessels training and following ships procedures surrounding them 74 SOLAS (2020 Cons.)III/19.2.1 - 30abc
Action required: 30 - Ship detained
Resolved 14 July 2022
Resolution: MSD Lake Worth received ISM audit from Bureau Veritas and successfully witnessed a satisfactory fire/abandon/passenger evacuation drill. Verification training of personnel with emergency duties was verified with emergency duties was verified. Def Cleared
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 July 2022 Resolved
The angular position of the rudder shall, if the main steering gear is power-operated be indicated on the navigation bridge. The bridge rudder angle indicator showed a difference of five degrees from the rudder angle indicator on the steering gear - 74 SOLAS (2004 Cons.)II-1/29.11.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2022
Resolved 25 October 2022
Resolution: Gyro unit was replaced. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2022 Resolved
Hoses specified in this chapter as “fire hoses” shall, together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections. Additionally, in interior locations in passenger ships carrying more than 36 passengers, fire hoses shall be connected to the hydrants at all times. 03 fire hoses were found disconnected from their associated hydrants - 74 SOLAS (1997 Cons.)II-2/4.7.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: 03 fire hoses were found disconnected from their associated hydrant were corrected on the spot. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 July 2022 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Galley located on deck 7 deep fat fryer suppression system had installed caps rendering the system ineffective - 74 SOLAS (2020 Cons.)II-2/14.2.1.2 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: PSCO observed Deck 7 deep fat fryer suppression system installed caps rendering the system ineffective were removed. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 July 2022 Resolved
Any required fire detection system shall be capable of immediate operation at all times. 02 smoke detectors were discovered to be inoperable - 74 SOLAS (1997 Cons.) Ch. II-2/12.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: PSCO verified 02 smoke detectors that were discovered to be inoperable were in proper working order. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 July 2022 Resolved
“A” class divisions shall be so constructed as to be capable of preventing the passage of smoke and flame. Fire doors throughout the ship were unable to fully close - 74 SOLAS (1997 Cons.)II-2/3.3.3 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2022
Resolution: PSCO's conducted spot check on various fire doors through the vessels main vertical zones with satisfactory results. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 July 2022 Resolved
Fire doors shall have an approximately uniform rate of closure of no more than 40s and no less than 10s. Fire doors throughout the ship were witnessed to close between one and five seconds - 74 SOLAS (1997 Cons.)II-2/30.4.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2022
Resolution: PSCO's conducted spot check on various fire doors through the vessels main vertical zones with satisfactory results. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 July 2022 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside of the spaces being ventilated. Fire damper located next to the portable power pack on the uppermost deck was inoperable - 74 SOLAS (1997 Cons.)II-2/32.1.1 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 25 October 2022
Resolution: MSD LW accepted class report attesting to proper repair. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 18 January 2022 Resolved
Drills shall be conducted as realistically as possible. Drills were not conducted in a fashion to replicate a real scenario.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 25 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 January 2022 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. A crack in the hull was found on the starboard side of the #6 lifeboat.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 25 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 January 2022 Resolved
Lifesaving appliances shall be fitted with retroreflective material to assist with detection. All rescue boats were found to not have proper tape on the hulls.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 January 2022 Resolved
Means of escape shall be marked by lighting or photoluminescent strip indicators. The strips in the luggage handling room were blocked and not visible.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 January 2022 Resolved
Means of escape marking must enable passengers to identify all routes of escape and readily identify escape exits. The rock bar on deck 10 has no way to identify means of escape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 January 2022
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 January 2022 Resolved
Only lockers of non-combustible materials providing storage for safety equipment and open information counters may be located within the stairway enclosure boundries. Items of non-safety combustible materials were found to be stored under the crew stairway in zone 6 on deck 3.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 January 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 January 2022 Resolved
Means of escape from control stations, accomodation spaces and service spaces. A glass door was foundto be impeding egress on Deck 9.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2021 Resolved
The capacity of generating sets identified or described in Regulation 41.1.1 shall be such that in the event of any one generating set being stopped it will still be possible to supply those services necessary to provide normal operational conditions of propulsion and safety. Minimum comfortable conditions of habitability shall also be ensured which include at least adequate services for cooking, heating, domestic refrigeration, mechanical ventilation, sanitary and fresh water. Vessel is provided with 4 diesel generators, 1 of which is not operational due to mechanical issues. The Chief Engineer and crew stated the remaining 3 diesel generators can only be run at approximately 50% load without the risk of overheating due to the age of the engines. During mooring operations and prior to utilizing the bow thruster, the crew must shed numerous and essential services from the switchboard to include mechanical ventilation. This shedding of the load is required to prevent the remaining diesel generators from overheating due to overloaded conditions. 74 SOLAS (1997) II-1/41.1.2 - 60 a c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 18 January 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 September 2021 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard. PSCO observed significant fuel oil leaks on the Number 1 Diesel Generator, Number 2 Diesel Generator, and Number 4 Diesel Generator. The leaks were apparent at the fuel oil leak tanks and were dripping at a rate of several drips per second. 74 SOLAS (1997) II-2/15.2 - 60 a c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2021
Resolved 23 September 2021
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 8 September 2021 Resolved
All external high-pressure fuel delivery lines between the high- pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high- pressure line failure. A jacketed pipe incorporates an outer pipe into which the high-pressure fuel pipe is placed,forming a permanent assembly. The jacketed piping system shall include a means for collection of leakages and arrangements shall be provided for an alarm to be given of a fuel line failure. With the presence of significant leaks as described in deficiency number 01, there were no associated active alarms for Number 1, Number 2, or Number 4 Diesel Generator leak tanks. 74 SOLAS (1997) II-2-15.2.9 - 60 a c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2021
Resolved 23 September 2021
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 September 2021 Resolved
All lifeboats shall be properly constructed and shall be of such form and proportions that they have ample stability in a seaway and sufficient freeboard when loaded with their full complement of persons and equipment. PSCO observed delaminated/damaged gel coat resulting in visible fiberglass fibers in way of the hull and/or keel on lifeboats 03, 05, and 06. 74 SOLAS (1997) III/41.1.1 - 17 a c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 September 2021
Resolved 8 September 2021
Resolution: Exam team witnessed satisfactory repairs while onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 September 2021 Resolved
The lifeboat engine, transmission and engine accessories shall be enclosed in a fire-retardant casing or other suitable arrangements providing similar protection. Such arrangements shall also protect persons from coming into accidental contact with hot or moving parts and protect the engine from exposure to weather and sea. Adequate means shall be provided to reduce the engine noise. PSCO observed the insulation for the engine cover to be damaged and torn away from the cover on Number 2 Lifeboat. 74 SOLAS (1997) III/41.6.9 - 17 a c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 September 2021
Resolved 8 September 2021
Resolution: Exam team witnessed satisfactory repairs to engine compartment insulation while onboard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 September 2021 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following requirements: the doors shall be self-closing and shall have an approximate uniform rate of closure of no more than 40s and no less than 10s with the ship in upright position. Fire doors: 4/200, 3/208, access to waste treatment room, and door adjacent to sprinkler station 1/3 outside of the starboard steering gear room do not operate as intended. 74 SOLAS (1997) II-2/30.4.1 - 17 a c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2021
Resolved 23 September 2021
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 12 July 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat #12 port engine is inoperable - 74 SOLAS (2020) III/20.2 - 30ac
Action required: 30 - Ship detained
Resolved 21 July 2021
Resolution: MSD Lake Worth received and accepted the Report of Survey. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 July 2021 Resolved
Any required fire detection system shall be capable of immediate operation at all times. Smoke detector 403 ADD 41 on deck 10 and 306/114 on deck 9 are not operational - 74 SOLAS (1997) II-2/12.1.1 - 30ac
Action required: 30 - Ship detained
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted satisfactory operational test of 02 affected smoke detectors. Def Cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 12 July 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the company. In meeting these requirements, the company should ensure that: the inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken. due to the objective evidence in the reported operational deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. PSCOs collected objective evidence that the vessel was not identifying non-conformities and following the inspection and reporting requirements of its SMS. An external audit conducted by the Flag is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port - 74 SOLAS(2020) Ix/3.1 ISM Code Part A Reg 3.3, 7, 10.2.2, 9.1, 10.1, 6.3, and 6.4 - 30ac
Action required: 30 - Ship detained
Resolved 23 July 2021
Resolution: Received the administration(Bahamas) interim deficiency list and MSD has accepted report to clear the detainable item related to the ISM. The ships SMS to be implemented and evidence shown by 23SEP21. Def 4a imposed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 July 2021 Resolved
Each power-operated sliding water tight door shall have an approximately uniform rate of closure under power and in no case less than 20 s or more than 40 s with the ship in the upright position. Vessel’s crew were unable to meet closure timeframe requirements during the test on water tight doors #12 and #13 - 74 SOLAS(2004) II-1/15.7.3.2 - 30ac
Action required: 30 - Ship detained
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted satisfactory operational test of WTD #12 and #13. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 July 2021 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. No fuel oil leaks shall be situated where spillage or leakage therefore can constitute a hazard by falling on heated surfaces. Fuel oil leak found at storage tank from regulating valve soaking the lagging covering the valve, creating an extreme fire hazard - 74 SOLAS (1997) II-2/15.2.4 - 30ac
Action required: 30 - Ship detained
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted visual inspection and observed new lagging/valve has been installed/fitted. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 July 2021 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside of the spaces being ventilated. 09 fire dampers located on deck 9 and 01 located on deck 8 in the stack space are inoperable 74 SOLAS (1997) II-2/16.9 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 July 2021
Resolution: MSD Lake Worth received and accepted the Report of Survey from RO. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 July 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. -The topping off pump for the sprinkler system protecting accommodation and public areas, lobbies, stores, workshops, mooring decks and cold rooms is unable to fill the pressure vessel automatically as the system is designed. -The sprinkler system protecting accommodation and public areas, lobbies, stores, workshops, mooring decks and cold rooms has two soft patches on the main discharge pipe at the pressure vessel. -The sprinkler system pump protecting the accommodation and public areas, lobbies, stores, workshops, mooring decks and cold rooms is out of service. -The mist fire suppression system protecting the Main Engines, Diesel Generators and the Purifier room is off and not in the automatic position. The Ultrafog fire suppression system fresh water supply tanks are below half full and not ready to supply sufficient water to the protected spaces 74 SOLAS(2020) II-2/14.2.1.2 - 30ac
Action required: 30 - Ship detained
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey and conducted satisfactory visual/operational test of all affected water spraying extinguishing system components and reviewed technician reports. Def Cleared.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 12 July 2021 Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons onboard. A massive leak was observed on the hydraulic oil storage tanks for the power-operated sliding water tight doors in the engine room, hydraulic oil subsequently sprayed all over PSCOs and crew - 74 SOLAS(1997) II-2/15.3 - 30ac
Action required: 30 - Ship detained
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted satisfactory operational test of affected power-operated sliding water tight doors. Def Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There is a concrete patch located on the main cooling water line for the ship’s diesel generators - 74 SOLAS(2020) I/11(a) - 30ac
Action required: 30 - Ship detained
Resolved 23 July 2021
Resolution: MSD Lake Worth received the administration(Bahamas) interim deficiency list and MSD has accepted report to clear the detainable item for the cement box. However a new deficiency will be imposed to reflect the flag state due date of for permeant repairs.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 July 2021 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization* and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. The Ultrafog system is past its manufacture annual service requirement 74 SOLAS(2020) II-2/14.2.2.1 - 30ac
Action required: 30 - Ship detained
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, conducted visual inspection of the Ultra-fog system, and reviewed technician report. All was found in proper working order. Def Cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Gauges on the section valves of the fire suppression system for the ship’s diesel generators are inoperable - 74 SOLAS(2020) II-2/14.2.1.2 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted visual inspection and observed new gauges installed/fitted. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 July 2021 Resolved
Means of escape, including stairwells and exits shall be marked by lighting or photoluminescent strip indicators. Installed low location photo luminescent strip is damaged and sections are missing in the port side corridor on deck 3 MVZ 6 in way of the linen store. Additionally, a vertical low location lighting strip on door #04030 located on deck 4 was inoperable - 74 SOLAS(1997) II-2/28.1.10 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted visual inspection and observed new photo luminescent tape and low location strips were installed in proper working order in affected areas. Def Cleared
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 July 2021 Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type II or III device that has a label on it under §159.16 or that is certified under §159.12 or §159.12a. PSCO observed multiple sewage leaks coming from MSD Type II piping - 33 CFR 159.7(a)(1) - 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted visual inspection and observed new section of piping installed for MSD. Def Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 July 2021 Resolved
During preparation and launching, the survival craft, its launching appliance, and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power. 02 Lighting arrangements for survival craft launching/recovery located starboard side by lifeboat #3 and above the deck line are extinguished - 74 SOLAS(1997) III/15.7 - 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and observed 02 lighting arrangements being delivered to the vessel during re-examination. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 July 2021 Resolved
Power ventilation of machinery spaces shall be capable of being stopped from an easily accessible position outside the space being served. Ventilation duct serving damper #7/39/3 is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2021
Resolved 21 July 2021
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 July 2021 Resolved
Every crewmember with assigned emergency duties shall be familiar with these duties before the voyage begins. Fire team #3 responsible for conducting boundary cooling during COC Annual fire drill, were not familiar with assigned duties and locations onboard to conduct boundary cooling 74 SOLAS(2020) III/19.2.1 - 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received and accepted the Report of Survey from RO. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 July 2021 Resolved
Fire Doors in main vertical sound bulkheads and stairway enclosures shall satisfy the following requirements: The Doors shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. Fire doors 4/206, 3/216, 4/138, 5/162, 4/140, 5/121, 3/127, 2/176, 1/78 and 2/218 have a closer time of less than 10 seconds 74 SOLAS(1997) II-2/30.4.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received new PSSC identifying multiple fire doors incapable of meeting the 10s-40s time frame for closure. The RO has issued a requirement of 19AUG21. Def Cleared. Def 18a will be added.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 July 2021 Resolved
Stairways and exits giving access to the muster and embarkation stations shall be lighted. Such lighting shall be capable of being supplied from the emergency source of electrical power. Multiple exit lighting arrangements are extinguished; Locations include: 01 light on Deck 3 above door #03063, 02 lights on deck 8 in forward Yellow Elder Restaurant, 01 light on deck 8 MVZ 1 in galley forward starboard escape route, 01 light located on deck 9 Par-A-Dice Casino starboard side and 01 on deck 8 located aft port side escape from the Encore Lounge - 74 SOLAS(1997) III/11.5 - 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted visual inspection of all affected lighting with satisfactory results. Def Cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 July 2021 Resolved
Each passenger state room and crew cabin shall be equipped with entry doors that include peep holes or other means of visual identification. As per vessels approved plans, cabins number 03062, 03064, 6039, and 03060 are not outfitted with peep holes or other means of visual identification 46 USC 3507(a)(1)(b) - 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD MSD Lake Worth received RO survey, and conducted satisfactory visual inspection of newly installed peep hole on affected doors. Def Cleared
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Diesel generator #1 has constant high fuel oil temperature alarms and the maintenance of the generator is not up to date - 74 SOLAS(2020) I/11(a) - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2021
Resolution: Received the administration(Bahamas) interim deficiency list and MSD has accepted report to clear the detainable item DG#1 high temp alarm. Bahamas(BMA) has imposed a 2 month time requirment for all maintenance to be up to date. Def 20a Imposed.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 12 July 2021 Resolved
Any Certificate required by the Convention must be kept available in its original form on board the ship on which the holder is serving. The officers onboard the vessel do not have their original Bahamian flag state endorsements STCW 78/95 Annex I/I/2.11 - 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth was provided Flag State(Bahamas) correspondence by ship management onboard attesting that electronic copies of officer endorsements were acceptable. MSD LW accepted this correspondence. Def Cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 July 2021 Resolved
The owner of a vessel to which this section applies shall maintain on the vessel adequate, in-date supplies of anti-retroviral medications and other medication’s design to prevent sexually transmitted diseases after a sexual assault. Vessel is required to be outfitted with three sexual assault kits as per company procedures. No sexual assault kits are onboard - 46 USC 3507(d)(1) - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD lake Worth conducted visual verification of 03 sexual assault kits onboard in medical facility. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 July 2021 Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14). A flammable locker located in the plumber’s workshop on deck 3 exceeded flammable liquid quantities necessary for practical/daily use of the space 74 SOLAS(1997) II-2/26.2.2 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received and accepted the Report of Survey from RO. Def Cleared
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2021 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. The microverter located in the electrical substation #03109 on deck 3 has exposed wires creating an electrical hazard. Additionally in the machinery space, 440v cables from the electro-chlorination panel found hanging with conductors visible; panel power light was illuminated - 74 SOLAS(2004) II-1/45.1.3 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, conducted satisfactory visual inspection of affected areas for electrical hazards. All found in proper order/secured. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 July 2021 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them closed, shall provide resistance to fire as well as the passage of smoke and flame. “A” Class fire doors #04001, #08083, #4036, and #04029 were incapable of latching 74 SOLAS(1997) II-2/30.2 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted satisfactory operational test of affected fire doors. Def Cleared.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 July 2021 Resolved
"A" Class divisions are those divisions formed by bulkheads and decks which shall be so constructed as to be capable of preventing the passage of smoke and flame to the end of the one hour standard fire test. Multiple penetrations were discovered in the crew gym located on deck 4, penetrating through the deck of “A” Class divisions - 74 SOLAS(1997) II-2/3.3 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, conducted visual inspection, and accepted the Report of Survey from RO. Def Cleared
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 July 2021 Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the life boat and life raft embarkation deck from all passengers and crew spaces and from spaces in which the crew is normally employed. A Room-in-room configuration was identified in the pharmacy located in the hospital on deck 3. The primary escape route from the pharmacy lead to another accommodation space. No Audible alarm is installed to notify crew - 74 SOLAS(1997) II-2.28.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 4 October 2021
Resolution: PSCO attended vessel and observed an audible room-in-room alarm installed in the pharmacy to alert ship's personnel. PSCO conducted satisfactory operational test of smoke detector that raised audible alarm. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 12 July 2021 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. PSCO identified multiple locations along the starboard wide where emergency lighting at embarkation stations are non-operational - 74 SOLAS(1997)III/11.4 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted satisfactory visual inspection renewed starboard side lighting. Def Cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 12 July 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Hot water pipes in the engine room are leaking and missing lagging - 74 SOLAS(2020) I/11(a) - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 21 July 2021
Resolution: MSD Lake Worth received RO survey, and conducted satisfactory visual inspection renewed lagging. Def Cleared.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 July 2021 Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14). The vessel has deviated from the approved space categorization plan in 02 locations; Hotel Office #03010 on deck 3, and Crew Office #03027 on deck 3. The approved vessel space categorization plan identifies both of these spaces as category 13 workshops however, they are being utilized as category 7 accommodation spaces of moderate risk - 74 SOLAS(1997) II-2/26.2.2 - 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 4 October 2021
Resolution: MSD Lake Worth received plans for the vessels space categorization updating the cat 13 workshops to accommodation spaces cat 7. Deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There is a concrete patch located on the main cooling water line for the ship’s diesel generators - 74 SOLAS(2020) I/11(a)
Action required: 705 - Other - as specified
Due 1 February 2022
Resolved 21 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 July 2021 Resolved
Fire Doors in main vertical sound bulkheads and stairway enclosures shall satisfy the following requirements: The Doors shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. Fire doors 3216, 1170, 2218, and 4206 have a closer time of less than 10 seconds 74 SOLAS(1997) II-2/30.4.1
Action required: 705 - Other - as specified
Due 19 August 2021
Resolved 4 October 2021
Resolution: PSCO attended vessel and conducted satisfactory visual tests of all affected self-closing fire doors. Deficiency cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 12 July 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the company. In meeting these requirements, the company should ensure that: the inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. PSCOs collected objective evidence that the vessel was not identifying non-conformities and following the inspection and reporting requirements of its SMS. An external audit conducted by the Flag is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port - 74 SOLAS(2020) Ix/3.1 ISM Code Part A Reg 3.3, 7, 10.2.2, 9.1, 10.1, 6.3, and 6.4
Action required: 705 - Other - as specified
Due 23 September 2021
Resolved 4 October 2021
Resolution: PSCO's conducted spot check of vessels SMS to include weekly / monthly checks for fire and lifesaving systems. Vessels AMOS system was operational. All was found in proper order. Deficiency Cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Diesel generator #1 has constant high fuel oil temperature alarms and the maintenance of the generator is not up to date - 74 SOLAS(2020) I/11(a) - 17ac
Action required: 705 - Other - as specified
Due 23 September 2021
Resolved 21 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 16 October 2019 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied by the emergency source of electrical power. PSC observed 15 nonfunctional lights at the embarkation stations supplied by the emergency source of electrical power
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Attended vessel to verify repairs and additionally recieved class report. All lights were replaced with new LED lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2019 Resolved
Under all sailing conditions including manouvering, the speed, direction of thrust, and if applicable, the pitch of the propeller shall be fully controllable from the navigation bridge. Upon shifting from main bridge control to starboard bridge wing contol, the port side reverse thrust/pitch was unresponsive and upon switching to emergency control, it remained unresponsive in reverse.
Action required: 705 - Other - as specified
Due 19 April 2019
Resolved 23 April 2019
Resolution: Company provided two technical reports attesting to the functionality of the system. 4 potentiometers, and 3 circuit boards were replaced. Additionally, received class report attesting to the repairs and the functionality of the system.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 April 2019 Resolved
Ventilation ducts...pass through "A" class decks exceeding .075m2 shall be fitted with fire damper. PSCO observed inverter room on deck 11 with ventilation fan missing and no fire damper in ventilation trunk.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 April 2019 Resolved
Damper operating position shall be readily accessible and be marked in red light reflecting colour. PSCO observed fire damper closure for gaylord in mini-galley deck 10 mislabeled and activation is in another space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 April 2019 Resolved
"A" class divisions are so constructed to be capable of preventing passage of smoke and flame. PSCO observed an open penetrationin the main vertical fire zone bulkhead between stairwell and casino cashier room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 15 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 April 2019 Resolved
Provision shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery. PSCO observed SSDG #4 overdue for general overhaul on prime mover. Fuel pumps on auxiliary engines for #1, #3, #4 generators are leaking diesel fuel internally.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 15 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 15 October 2018 Resolved
The launching mechanism shall be so arranged that it may be actuated by one person from a position on the ships deck and except for secondary launching appliances for free-fall lifeboat, from a position withing the survival craft or rescue boat. During lowering of rescue boat #2, eyebold on brake release sheared preventing the manual release from the vessel.74SOLAS(97 cons) CH III, LSA 6.12.2
Action required: 10 - Deficiency Rectified
Resolved 15 October 2018
Resolution: Vessel crew replaced mechanism with onboard spares.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 October 2018 Resolved
All openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Automatic latching mechanism on starboard side mini-galley found inoperable.
Action required: 10 - Deficiency Rectified
Resolved 15 October 2018
Resolution: Vessel crew replaced door handle.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.