Records from 1992 to 1993. Most recent: inspection, 9 April 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE OPERABLE OXYGEN INDICATOR. DEMONSTRATE OPERATION TO ATTENDING USCG REPRESENTATIVE.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR REPAIRS TO CARGO HOSE SADDLES (CRADLES) WHERE WASTED AT PORT AND STBD SIDE OF THE VESSEL.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CALIBRATION GAS AND DEMONSTRATE CALIBRATION OF COMBUSTIBLE GAS INDICATOR IN THE PRESENCE OF A USCG REPRESENTATIVE.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE UPDATED CLASS SOCIETY REPORT ON THE STATUS OF THE FOLLOWING OUTSTANDING CLASS RECOMMENDATIONS FROM RPT DTD 06OCT92 ITEMS: CZ RPT 05521 OF 26APR92, SG RPT 72906 OF 10DEC91, SG RPT 72907 OF 10DEC91, BN 13479 OF 24SEP91 AND RO RPT 35974 DTD 28JAN91.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT OF PERMANENTREPAIRS TO WASTED BALLAST PIPING WHERE TEMPORARILY PATCHED ON STARBOARD MAIN DECK IN VICINITY OF PUMPROOM #4 AND #8 STBD CARGO TANK. RENEW BALLASTPIPING SUPPORT BRACKETS WHERE WASTED IN SAME LOCATION.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS AND USE OF #1 CARGO PUMPROOM VENTILATION FAN MOTOR REPAIR BROKEN ELECTRICAL CONDUIT FOR FAN MOTOR. PROVIDE CLASS SOCIETY REPORT OF REPAIRS.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT OF PERMANENTREPAIRS TO NUMEROUS LEAKS IN TANK WASH MAIN SUPPLY PIPING UNDER RAISED WALKWAY ON MAIN DECK CREATING A SAFETY HAZARD.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1993
Resolved
PRIOR TO CARRYING A FLAMMABLE/COMBUSTIBLE CARGO IN U.S. WATERS PROVIDE CLASS SOCIETY REPORT OF PERMANENT REPAIRS TO PUMPROOM VENTILATION HOUSINGS IN CARGO PUMPROOMS 1,2,4 AND 5.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1993
Resolved
PRIOR TO UTILIZING PORT SIDE BUNKER PIPING IN U.S. WATERS AND PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT OF PERMANENT REPAIR TO THE PORT FORWARD CARGO MANIFOLD/BUNKER PIPING CONTAINMENT.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS AND UTILIZING STEAM HEATING COILS IN U.S.WATERS PROVIDE CLASS SOCIETY REPORT OF PERMANENT REPAIRS TO THE MAIN DECK FORE AND AFT STEAM SUPPLY LINE LEAKS LOCATED UNDER THE RAISED WALKWAY CREATING A PERSONAL SAFETY HAZARD.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1993
Resolved
PRIOR TO CARRYING FLAMMABLE/COMBUSTIBLE CARGO IN U.S. WATERS PROVIDE CLASS SOCIETY REPORT OF REPAIR/RENEWAL OF FLAME SCREEN (30 X 30 MESH) FOR ALL PUMPROOM VENTILATORS.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR PERMANENT REPAIRS TO WASTED MAIN DECK CONTAINMENT ALONG PORT AND STBD SIDE OF VESSEL.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR PERMANENT REPAIRS TO WASTED AREA OF FOCSLE WATERTIGHT BULKHEAD IN WAY OF STEAM PIPING PENETRATIONS LOCATED PORT SIDE OF VESSEL'S CENTERLINE.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR PERMANENT REPAIR TO FORWARD WATERTIGHT BULKHEAD OF ACCOMMODATIONS HOUSE ON THE MAIN DECK AT VESSEL'S CENTERLINE WHERE WASTED IN WAY OF STEAM PIPING.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR PERMANENT REPAIRS TO FRACTURE OF CARGO TANK HATCH SUPPORT ARM WHERE ATTACHED TO THE TOP OF THE PIVOT ARM FOR THE FOLLOWING HATCHES: 6 STBD, _x001C_ 2 STBD AND #5 PUMPROOM PORT SIDE OUTER CARGO TANK.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR REPAIRS/CLOSURE OF TWO 3" PIPE OPENINGS AND ONE BULKHEAD PENETRATION IN WAY OF FOCSLE WATERTIGHT BULKHEAD LOCATED ON STBD SIDE OF VESSEL'S CENTERLINE.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR PERMANENT REPAIRS TO 12" WASTED SECTION OF THE FOCSLE WATERTIGHT BULKHEAD PORT SIDE AT THE MAIN DECK.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR RENEWAL OF MAIN DECK FORE AND AFT PIPING SUPPORT HANGERS WHERE WASTED UNDER RAISED WALKWAY CONTRIBUTING TO POSSIBLE PERSONAL HAZARD.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR REPAIRS TO RAISED MAIN DECK WALKWAY FRAMING WHERE WASTED CONTRIBUTING TO POSSIBLE PERSONAL SAFETY HAZARD. PROVIDE CLASS ACCEPTANCE OF THE WOODEN WALKWAY DECKING PRESENTLY USED ON THE RAISED MAIN DECK WALKWAY ON THIS TANK VESSEL.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S WATERS PROVIDE CLASS SOCIETY REPORT FOR PERMANENTREPAIRS TO BROKEN/WASTED DECK GRATING IN #2 PUMPROOM BEHIND THE LADDER ON THE LOWER LEVEL.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 9 April 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT FOR PERMANENT REPAIRS TO EMERGENCY FIRE PUMP EXHAUST PIPING AT FLEX COUPLING.
Condition: Unknown
Due 10 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 January 1992
Resolved
MAKE PERMANENT(WELDED) REPAIRS TO THE CRACK IN THE SIDE SHELL IN WAY OF THESTARBOARD FORWARD DEEP TANK (FUEL OIL) PRIOR TO DEPARTURE NEW ORLEANS, LOUISIANA. CRACK IS VERTICAL ALONG TRANSVERSE BULKHEAD WHICH FORMS THE AFTTANK BOUNDARY AND ABOUT 24 INCHES LONG. (TEMPORARY REPAIRS MADE IN LA/LB)
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Deck/Cargo
Issued 27 January 1992
Resolved
CONDUCT A PRESSURE TEST OF CARGO PIPING TO AT LEAST 15.3 KG/CM2 (225 PSI) BY COMPLETION OF NEXT SCHEDULED DRYDOCKING. (PIPING WAS TESTED TO 10 KG/CM2 ON 05DEC91. 15.3 KG/CM2 TEST IS TO BE COMPLETED AT LEAST TWICE IN EVERY FIVE YEARS, TYPICALLY DONE AT DRYDOCKING.)
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992