NATHANIEL B. PALMER

NATHANIEL B. PALMER is a 1992 research vessel. The Coast Guard has recorded 68 inspections since 1992, most recently in April 2025, along with 123 deficiencies and 1 casualty investigation in 2014.

Records from 1992 to 2025. Most recent: inspection, 17 April 2025.

Built
1992
Last inspected
17 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9007257 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBP3210
370420
Flag
UNITED STATES
366610000
Maury page id
psix-370420

Inspections, by type

…with no type recorded7
Years with a record 31 calendar years (1992–2025)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)281.3 ft × 60.0 ft × 31.0 ft
Registered tonnagegross 6,174 / net 1,852
ITC dimensions (L × B × D)281.3 ft × 60.0 ft × 31.0 ft
ITC tonnagegross 6,174 / net 1,852
BuilderNORTH AMERICAN SHIP BUILDING · LAROSE · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6174 - Convention (Subpart B), Gross Ton
1852 - Convention (Subpart B), Net Ton
6800 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBP3210MMSI 366610000 · active · compulsorily equipped · granted 15 December 2017, expires 14 January 2028 · licensed under a name not among this hull’s recorded names (not shown)
WCE9345MMSI not assigned · expired · compulsorily equipped · granted 31 March 1994, cancelled 6 June 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 68

17 April 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8115263
8 June 2024 Drydock Exam · MARPOL Annex VI Survey · MARPOL Annex V Examination · Polar Code Examination · MARPOL Annex IV Survey · Ballast Water Examination · MARPOL Annex I Examination · Internal Structural Exam · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7888123
18 September 2023 Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7763214
21 June 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7720041
16 August 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7538041
25 July 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7516225
26 March 2022 MTSA/ISPS Verification · Annual Inspection · Internal Structural Exam · Drydock Exam · MARPOL Annex IV Survey · MARPOL Annex I Examination · MARPOL Annex V Examination · Polar Code Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7406038
27 April 2021 COI Inspection · MARPOL Annex V Examination · Polar Code Examination · MARPOL Annex IV Survey · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7137439
15 January 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7125154
8 December 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7108097
3 June 2020 Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6967507
26 May 2020 Polar Code Examination · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 6961781
15 April 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6939401
16 July 2019 MTSA/ISPS Verification · Annual Inspection · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · Polar Code Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6678014
18 June 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6677969
23 May 2018 Ballast Water Examination · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex IV Survey · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6404089
9 March 2017 Annual Inspection · Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6101541
16 November 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6042532
21 May 2016 Hull Examination · COI Inspection · MARPOL Annex I Examination · Ballast Water Examination · MTSA/ISPS Verification · MARPOL Annex VI Survey · MARPOL Annex IV Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5854192
18 August 2015 Plan Review (Other than "T")
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5219954
6 August 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5207686
20 July 2015 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5167911
29 May 2014 Drydock Exam · Internal Structural Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4856475
15 May 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4862348
17 May 2012 MARPOL Annex I Examination · Annual Inspection · Internal Structural Exam · Hull Examination · MARPOL Annex IV Survey · MARPOL Annex VI Survey · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4299819
19 November 2010 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3895076
29 September 2010 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3859565
7 October 2008 Annual Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3348594
11 July 2007 Annual Inspection · Hull Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3020407
14 September 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2778260
17 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2751377
30 May 2006 Administrative Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2664508
12 April 2006 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2623226
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502135
23 September 2005 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2513162
17 August 2005 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2465577
21 February 2005 In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2301074
7 September 2004 Annual Inspection · MARPOL Annex V Examination · Hull Examination · Inclining Experiment · Examination of Repairs · MARPOL Annex I Examination · Liferaft Servicing · Internal Structural Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2181744
28 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2064802
9 September 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1900904
17 June 2003 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1805784
9 November 2002 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1702900
28 October 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1697781
24 October 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1695414
23 October 2002 Internal Structural Exam · Drydock Extension
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1694753
19 October 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1694253
18 October 2002 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1692265
15 July 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395780
25 September 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361724
21 December 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811694
15 August 1999 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402929
20 August 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 119148
25 April 1998 COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 792301
19 July 1997 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402525
4 March 1997 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 774599
12 April 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459985
6 November 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430103
22 July 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358857
15 June 1994 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398083
1 March 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1166458
23 December 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1159309
5 November 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 844090
14 October 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 833645
12 October 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1137777
6 August 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1391884
17 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1149102
12 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 833006
1 March 1992 Initial Certification · Deadweight Survey · Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947646

Deficiency record · 123

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 18 September 2023 Resolved
Design verification testing (a) Tests must verify that automated vital systems are designed, constructed, and operate in accordance with all applicable requirements of part 62 of this sub chapter. The tests must be based upon the failure analysis, if required by §62.20-3(b) of this sub chapter, functional performance requirements, and the Periodic Safety tests of §61.40-6. (b) Tests must be performed immediately after the installation of the automated equipment or before the issuance of the initial Certificate of Inspection.Chief Engineer shall provide objective evidence that all automation test procedures are completed prior to movement for all Main Diesel Engines. 46CFR61.40-3 60c
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 November 2023
Resolution: Vessel conducted Safety test procedures. all alarms were tested with satisfactory results.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 March 2022 Resolved
Before a ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. STBD lifeboat bilge system inop. 74SOLAS2020 III/20.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2022
Resolution: Received confirmation from Port Eng that bilge pump was repaired and tested.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 March 2022 Resolved
At each inspection for certification and periodic inspection the MI shall conduct such tests and inspections of the main propulsion and auxiliary machinery. Port outboard MDE low lube oil shutdown not working as intended. 46CFR61.20-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2022
Resolution: Received confirmation from Port Eng that Cat techs repaired low lube oil shutdown and tested.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the sip in all respect will remain fit to proceed to sea without danger to the ship or persons on board. Observed steering HYD oil leak on port pump number one and steering ram hoses. 74SOLAS2020 I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2022
Resolution: Received confirmation from CE that port/port steering HPU and all 4 HYD hoses were changed out.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 March 2022 Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. The drills of the crew shall take place within 24 hours of the ship leaving port if more than 25% of the crew have not participated in abandon ship and fire drills onboard the particular ship in the previous month. Vessel fail to perform fire drills in accordance with regulation. Master shall create a non conformity and corrective action plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 March 2022
Resolution: Received non conformity and CAP from master.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 May 2020 Resolved
Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear. The port rudder angle indicator located at the main steering station on the bridge was not functioning. Repair or replace the port rudder angle indicator and prove operation in the presence of a Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 26 May 2020
Resolved 3 June 2020
Resolution: The port rudder angle indicator located at the main steering station on the bridge was repaired and tested in the presense of a Coast Guard Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 August 2019 Resolved
Annual maintenance on galley rolling A0 fire doors has not been conducted since delivery of vessel. Create maintenance task in your preventive maintenance system to prevent future occurrences.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2019
Resolution: Received 3rd party certificate attesting to annual maintenance.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 25 June 2019 Resolved
Maintenance, testing and inspections shall be carried out based on the guidlines developed by the orgaization and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. Annual drop test/maintence on galley serving line fire door has not been conducted since delivery of vessel. Creat maintenance task in preventive maintance system to prevent future occurrences. 74 SOLAS II-2 Reg 14.2.2.1 , NFPA 80
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2019
Resolved 8 July 2019
Resolution: Fire door tested.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 9 April 2017 Resolved
Repair/Replace damaged SFP insulation on bulkhead aft of CO2 room IWO fan space.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 May 2018
Resolution: Witnessed satisfactory repair of SFP of CO2 room IWO fan space.
Lifesaving › Launching Appliances › Winch Brake
Issued 9 April 2017 Resolved
Emergency use ONLY allowed for port L/B until winch brake is inspected and tested by competent authority. Ammend SMS to reflect additional safety measures necessary in the event of needing to use the L/B for emergency.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 May 2018
Resolution: Lifeboat break was replaced and tested and found to be working order.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 9 April 2017 Resolved
Replace 7 unapproved portable fire extinguishers with CG Approved ones.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 May 2018
Resolution: Observed receipt for new fire extinguishers. All fire extinguishers according to the FCP were of the CG approved type.
Lifesaving › Immersion Suits › Serviceable
Issued 9 April 2017 Resolved
Replace all "Baleysuit" brand Immersion Suits upon return to Valparaiso, Chile. Manufacturer calls for replacement after 10 yrs of age.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 May 2018
Resolution: CG inspected required immersion suits and no "Baleysuit's" were observed. All other immersion were found satisfactory.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 9 March 2017 Resolved
Provide proper closure to penetration duct between Baltic Room and Wet lab.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 May 2018
Resolution: Penetration between Baltic room and Wet lab has been fixed. Rockblock type fire protection was installed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Governor
Issued 16 November 2016 Resolved
[name withheld] reported stbd outbd main engine governor had been iscovered to be inoperable and in need of repair. Make proper repairs to the satisfaction of the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 20 December 2016
Resolution: Received email with report attached and a statement from master stating repairs have been made.
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 14 June 2014 Resolved
USCG Inspectors found water intrusion into foam filled inner hull and subsequent water logging of foam. In consult with vessel operator, condemned rescue boat. Vessel allowed temporary use of Zodiac inflatable boat while awaiting delivery of new fast rescue boat. Vessel to provide documentation to USCG MI demonstrating installation of approved rescue boat.
Due 22 September 2014
Resolved 25 August 2014
Resolution: New rescue boat installed. Documentation sent showing installation of approved rescue boat.
Lifesaving › Launching Appliances › Winch Brake
Issued 14 June 2014 Resolved
Third party inspectors found cracks in the carry areas of the winch brakes on both lifeboat winches. Due to non-availability of replacements, authorized temporary repairs after consult with manufacturer while awaiting replacement part manufacture. Vessel to provide USCG MI with documentation showing replacement of brake carry on both winches and completion of successful davit weight test.
Due 17 October 2014
Resolved 25 September 2014
Resolution: Received servicing reports and ABS statement of fact attesting to repair and testing of winch brakes.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 11 July 2007 Resolved
Prove 1.5 MAWP of foam piping system.
Due 17 August 2007
Resolved 21 July 2007
Deck/Cargo › Cargo Stowage › General
Issued 11 July 2007 Resolved
Prove 1.25 load test on stern "A" frame crane.
Due 17 August 2007
Resolved 21 July 2007
Personnel › Certificates/Documents/Licenses › MMD, Able Seaman
Issued 30 May 2006 Resolved
Vessel employs non US citizens in unlicensed deck and engineering positions. Current crew list attached in MISLE. As required by 46 USC 8103 vessel must insure all unlicensed crewmembers are citizens on the United States of America.
Due 21 July 2006
Resolved 22 September 2006
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 23 September 2005 Resolved
Prove propeller/shaft alignment problem has been diagnosed and repaired by an approved life boat facility on life boat #1. Vessel is restricted to the dock in a "no sail" status after the due date assigned.
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 12 April 2006
Lifesaving › Visual Distress Signals (General) › Expired
Issued 23 September 2005 Resolved
Provide documentation showing two (2) operational SART's on the vessel.
Due 23 October 2005
Resolved 18 November 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 February 2005 Resolved
Test newly installed bulkhead between fuel oil tank 4A and 4B in the presence and to the satisfaction of the attending CG Marine Inspector. This item to be cleared prior to the vessel departing port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2005
Resolution: Witnessed testing - all sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 February 2005 Resolved
Provide USCG MSC approved plans of the newly installed bulkhead separating fuel oil tanks 4A and 4B. This item is to be cleared no later than 24MAR05.
Due 24 March 2005
Resolved 17 August 2005
Resolution: Received MSC approval letters.
Engineering › Fuel Oil Service System › Piping
Issued 21 February 2005 Resolved
Properly test fuel oil piping installed in conjunction with alterations made to #4 fuel oil tank to the satisfaction of attending USCG Marine Inspector. This item to be cleared prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2005
Resolution: Witnessed testing - all sat.
Construction/Loadline › Structures › Deck Plating
Issued 21 February 2005 Resolved
Provide ABS approved drawings for deck strengtheners IWO deck where temporary derrick will be installed. This item to be cleared no later than 24MAR05 or at the time when the derrick is actually installed. The derrick is not to be installed until this item is cleared.
Due 24 March 2005
Resolved 17 August 2005
Resolution: Received MSC approval letters.
Stability › Incline Test › General
Issued 21 February 2005 Resolved
Provide necessary stability information and calculations to USCG MSC for determining if an inclining will be required after the derrick is installed. Copy to be sent to USCG Far East Activities. This item is to be cleared no later than 24 March 2005.
Due 24 March 2005
Resolved 17 August 2005
Resolution: Received MSC approval letters.
Stability › Incline Test › General
Issued 21 February 2005 Resolved
Provide final report of permanent ballast installation to USCG Far East Activities. This report should be included in the submittal to clear item 5.
Due 24 March 2005
Resolved 10 March 2005
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 15 September 2004 Resolved
Hello deck safety nets wasted, broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New safety nets installed.
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 7 September 2004 Resolved
Attach IMO number to exterior of hull IAW SOLAS.
Condition: Improper/Lack of Maintenance
Due 30 September 2004
Resolved 30 September 2004
Resolution: item completed at drydock.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 September 2004 Resolved
Conduct hydrostatic testing of portable / fixed DOT cylinders at an approved facility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 June 2006
Engineering › Steering Gear System › Rudder
Issued 7 September 2004 Resolved
Rudders have severe pitting/wastage. Drain plugs completely disintegrated. Informed by operator that CAPAC system was not operating properly.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Port and stbd rudders repaired per ABS proposal. New drain plugs installed.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 7 September 2004 Resolved
Repair fore and aft stern tube bearings, seal boxes and seals to both shafts. Repair damaged fiberglass wrap on the stbd shaft and conduct spark testing both shafts. Conduct NDT at the flange end of both shafts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Above repairs carried out to ABS satisfaction.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 7 September 2004 Resolved
Gas free and ready the number 3P/S, 6P/S, 7, 8, skeg void and bow thruster compt. for inspection.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 14 September 2004
Resolution: Tanks gas freed and mucked out for inspection.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 7 September 2004 Resolved
Ready for inspection all starting and control air receivers.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 15 September 2004
Resolution: All air receivers opened for inspection.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 7 September 2004 Resolved
Repair damaged electrical calbe to the #1 SSDG. Cable must be approved marine grade, in kind.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 29 December 2004
Resolution: Rcvd ABS reply that new cable installed and performance test of the #1 SSDG all sat.
Accommodation/Occupational Safety › Potable Water System › General
Issued 7 September 2004 Resolved
Crop and renew the wasted H2O piping in the engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New piping installed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 September 2004 Resolved
General housekeeping. Remove rags from electrical appliances and engines, and cardboard boxes from behind the SSDG's. This is a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 9 September 2004
Resolution: Rags removed from operating equipment and electrical appliances. Cardboard boxes removed from E/R and space cleaned up.
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 September 2004 Resolved
Close the 2" penetration btwn the lower aft E/R bulkhead and shaft alley.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2004
Resolved 30 September 2004
Resolution: Penetration properly closed w/blank flange.
Stability › Watertight Integrity › General
Issued 7 September 2004 Resolved
Prove proper operation of E/R watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2004
Resolved 30 September 2004
Resolution: Watertight doors tested sat.
Engineering › Sea-water System (primary cooling) › Valve
Issued 7 September 2004 Resolved
Ready sea valves for inspection, prior to undocking.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 27 September 2004
Resolution: All sea vavles cleaned and/or repaired.
Fire Fighting › Fire Main › Material
Issued 7 September 2004 Resolved
Crop and renew watsted fire main piping in E/R. Conduct 1.5 MAWP hydro testing when repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Fire main piping renewed and tested. all sat.
Electrical › Electric Supply System (service) › Cable
Issued 7 September 2004 Resolved
Properly support all E/R electrical cable runs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Additional cable trays installed.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 7 September 2004 Resolved
Replace the non-operable power lamps on both boilers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New lamps installed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 September 2004 Resolved
Properly adjust door closures to the fire doors in the stairtower, passageways, and laundry room 103.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Door closures adjusted and/or replaced, all sat.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 7 September 2004 Resolved
Repair the worn/damaged external cathodic protection cells and prove proper operation of the system.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 28 September 2004
Resolution: New cells installed/repaired and system test all sat.
Fire Fighting › Means of Escape › Blocked
Issued 7 September 2004 Resolved
Prove proper operation of the Aquarium room escape hatch. Excessive paint is hindering operation of the counter balance spring for the hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Paint removed from counter balance spring, test all sat.
Communications › Internal Communications System › Sound-powered Telephone
Issued 7 September 2004 Resolved
Prove proper operation of the rotating light for the E/R and steering gear sound powered phone system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New electrical relay installed, test sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 September 2004 Resolved
Install additional lagging on turbochargers for all E/R SSDG's.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Additional lagging installed on E/R SSDG turbochargers.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 7 September 2004 Resolved
Conduct 1.5 MAWP hydro on the #3 E/R air rcvr. Internal exam indicates excessive wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Hydro test completed, all sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 7 September 2004 Resolved
Prove proper operation of the emergency air damper shut down in the E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Damper control switch repaired, all sat.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 September 2004 Resolved
Pump waste oil from E/R bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: E/R bilges pumped.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 September 2004 Resolved
Install additional lagging on the emergency generator turbocharger.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Additional lagging installed.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 7 September 2004 Resolved
Reroute electrical cable that is obstructing the fuel shutoff valve to the emergency generator.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 7 September 2004 Resolved
Properly close electrical cable penetrations in the emergency generator space; fwd inboard bulkhead, and the deck below the air receiver.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Penetrations properly filled.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 September 2004 Resolved
Properly dead end wiring in the emergency generator control box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Wiring properly dead ended.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 September 2004 Resolved
Remove oily residue from the #7 ballast tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Tank cleaned by crew and witnessed by ABS.
Construction/Loadline › Hull › Bottom Plating
Issued 7 September 2004 Resolved
Install the missing bolt on the transducer flange in the cofferdam.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Item completed.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 7 September 2004 Resolved
Reinstall A-60 insulation on the fwd bulkhead of the emergency generator space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Additional insulation installed.
Construction/Loadline › Structures › Trunk
Issued 7 September 2004 Resolved
Properly install penetration blocks for the Science mast outside of the emergency generator space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Penetration blocks properly installed.
Lifesaving › Immersion Suits › General
Issued 7 September 2004 Resolved
Provide protective bags for the two exposure suits indicated.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New bags ordered.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 7 September 2004 Resolved
Provide/prove proper operation of PFD water lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New lights installed/tested.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 September 2004 Resolved
Prove proper operation of all NAV lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New lights installed/tested.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 7 September 2004 Resolved
Provide approved first aid kits for lifeboats, rescue boat and other stations throughout the vsl.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: First aid kits on order.
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 September 2004 Resolved
Prove proper operation of the bridge MAG compass light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New MAG compass installed.
Accommodation/Occupational Safety › Ventilation › General
Issued 7 September 2004 Resolved
Install vent head diffuser in room 210.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Diffuser installed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 September 2004 Resolved
Install closure device for the fire door located on the 01 level, port fwd.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New door closure installed and tested.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2004 Resolved
Remove the spliced 110v electrical wiring located in the walk in freezer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Wiring removed.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 7 September 2004 Resolved
Clean the walk-in freezer fans shrouds of dirt and grime.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Fan shrouds cleaned.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 7 September 2004 Resolved
Install wood float on the port lifeboat lifeline.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: New float fastened to lifeline.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2004 Resolved
Prove proper operation of all deck lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Bulbs replaced.
Fire Fighting › Fire Hoses › Condition
Issued 7 September 2004 Resolved
Fire hose fittings leak when tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Hose fittings tightened or replaced.
Lifesaving › Lifeboat Equipment › Batteries (electric torch spares)
Issued 7 September 2004 Resolved
Expired spare batteries, bulbs, first aid kit meds; missing hatchet lanyard & flat tip screwdriver; test proper ops of bilge pump. Rescue boat compass in-op.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: All equipment properly restored.
Construction/Loadline › Structures › Door
Issued 7 September 2004 Resolved
Wx deck hospital door/escape frozen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Hinges and dogs freed and lubricated.
Engineering › Pressure Vessel › Marking and Stamping
Issued 7 September 2004 Resolved
Found numerous non-DOT cylinders on board vsl, i.e. acetylene, oxygen, nitrogen, argon, etc.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 30 September 2004
Resolution: Master stated the non-DOT cylinders will be removed at next port. Took his word for it and cleared this item.
Lifesaving › Inflatable Liferafts › Servicing
Issued 7 September 2004 Resolved
Operator failed to conduct annual servicing on life rafts. No request to extend servicing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2004
Resolved 30 September 2004
Resolution: Witnessed annual servicing on all six (6) life rafts.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 7 September 2004 Resolved
Dry stores and engineroom adrift. General housekeeping.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2004
Resolved 30 September 2004
Resolution: Crew conducted general housekeeping.
Construction/Loadline › Structures › Machinery Space Opening
Issued 7 September 2004 Resolved
The Aquarium room escape hatch not marked "Emergency Exit Do Not Block".
Condition: Placed in Improper Service
Due 30 September 2004
Resolved 30 September 2004
Resolution: "Emergency Exit Do Not Block" stenciled IWO the Aquarium room escape hatch.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 7 September 2004 Resolved
The knife edges of the Baltic Room door are intermittently welded. Found during hose testing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 12 October 2004
Resolution: Rcvd report from shipbuilder that the design of the Baltic Room door knife edges was approved by ABS/ CG at certification. The reason for the intermittent welding was to reduce excessive heat, which would have damage the knife edge. Item rescinded.
Engineering › Sea-water System (primary cooling)
Issued 19 June 2003 Resolved
Replace the water regulating valve in the seismic compressor cooling system LEGACY COMPONENT DESC: Compressor Water Regulating Valve
Due 15 September 2003
Resolved 9 September 2003
Engineering › Shafting/Propeller Arrangements
Issued 18 October 2002 Resolved
Port propulsion shaft main seal lieaking. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2002
Resolved 23 October 2002
Engineering › Pressure Vessel
Issued 18 October 2002 Resolved
Prove proper operation of the siesmic air system main pressure relief valve. Valve is located in the steering compartment, on the compressor discharge piping. LEGACY COMPONENT DESC: Relief Valve
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2002
Resolved 23 October 2002
Resolution: PRVs were removed and bench tested at local facility. Both valves were adjusted to relieve @ 2200psi.
Engineering › Diesel Engine (auxiliary)
Issued 18 October 2002 Resolved
Repair or replace control module for #2 ships service generator prime mover. Control module operates engine emergency shut down system and is working intermittently. LEGACY COMPONENT DESC: Overspeed Device
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2002
Resolved 23 October 2002
Resolution: New speed control module was installed
Stability › Watertight Integrity
Issued 18 October 2002 Resolved
Repair and prove proper operation of the #4 watertight door between the lower engine room and shaft alley. There is a four minute delay, after door operates in either direction, before the door can be moved in the opposite direction. LEGACY COMPONENT DESC: Powered Watertight Doors
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2002
Resolved 23 October 2002
Resolution: Door repaired and proved operable.
Engineering › Freshwater System (jacketwater cooling)
Issued 18 October 2002 Resolved
Repair or replace jacket water piping in way of #2 main propulsion diesel engine, jacket water piping, pipe between pump and engine. Pipe has a "pinhole leak". LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2002
Resolved 23 October 2002
Resolution: Vessel''s crew installed new jacket water piping.
Fire Fighting › Structural - A Class Divisions
Issued 18 October 2002 Resolved
Prior to getting underway, prove proper operation of all fire doors. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2002
Resolved 29 October 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 18 October 2002 Resolved
Prior to getting underway prove proper operation of fixed fire fighting time delays.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2002
Resolved 23 October 2002
Resolution: Port engineer provided documentation showing ABS witnessed under authorization of MSO New Orleans during drydock. Confirmed with NOLMS.
Construction/Loadline › Markings
Issued 18 October 2002 Resolved
Paint draft marks contrasting color to the hull. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 19 November 2002
Resolved 23 October 2002
Personnel › Manning/Qualifications
Issued 18 October 2002 Resolved
Prior to getting underway properly man vessel in accordance with COI safe manning requirements. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2002
Resolved 29 October 2002
Construction/Loadline › Structures
Issued 18 October 2002 Resolved
Prior to use, provide Coast Guard approved plans for crane installation.
Action required: 705 - Other - as specified
Due 19 November 2002
Resolved 23 October 2002
Resolution: Port Engineer provided plans showing ABS only approval, not 10-82l. CG MSC stated nothing further was required and sited 46CFR190.01-10
Construction/Loadline › Structures
Issued 18 October 2002 Resolved
Provide Coast Guard approved plans for moon pool modifications.
Action required: 705 - Other - as specified
Due 19 November 2002
Resolved 23 October 2002
Resolution: Port Engineer provided plans showing ABS only approval, not 10-82l. CG MSC stated nothing further was required and sited 46CFR190.01-10
Lifesaving › Lifebuoys
Issued 18 October 2002 Resolved
Provide SOLAS approved 4kg weighted ring buoys on bridge wings for use with smoke activation. LEGACY COMPONENT DESC: Self-Activitating Smoke Signals
Action required: 705 - Other - as specified
Due 19 November 2002
Resolved 29 October 2002
Electrical
Issued 18 October 2002 Resolved
prove proper operation of all gauge lighting on watertight door panel on the bridge.
Due 19 November 2002
Resolved 23 October 2002
Resolution: Replaced all faulty lights.
Lifesaving › Launching Appliances
Issued 18 October 2002 Resolved
Prior to getting underway, conduct weight test of all lifeboats. LEGACY COMPONENT DESC: Falls
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2002
Resolved 23 October 2002
Resolution: Port engineer provided documentation showing ABS witnessed under authorization of MSO New Orleans during drydock. Confirmed with NOLMS.
Lifesaving › Buoyant Smoke Signals
Issued 18 October 2002 Resolved
Replace expired smokes on port/stbd bridge wing.
Due 23 November 2002
Resolved 29 October 2002
Lifesaving › Liferaft Equipment
Issued 18 October 2002 Resolved
Prior to getting underway, properly install liferafts utilizing weak link off of hydrostatic release for all liferafts.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2002
Resolved 29 October 2002
Lifesaving › Lifeboat
Issued 18 October 2002 Resolved
Place call sign and # of boat on port/stbd lifeboats. LEGACY COMPONENT DESC: Markings
Due 23 November 2002
Resolved 23 October 2002
Navigation
Issued 18 October 2002 Resolved
Prove proper operation of all navigation lights.
Due 30 October 2002
Resolved 29 October 2002
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers
Issued 18 October 2002 Resolved
Provide service report for semi-portable extinguishers attesting to correct agent and replaced service hoses. LEGACY COMPONENT DESC: Condition
Due 23 November 2002
Resolved 29 October 2002
Fire Fighting › Automatic Sprinkler System
Issued 18 October 2002 Resolved
Prove proper operation of helo deck and pump room sprinkler pump. LEGACY COMPONENT DESC: Pump
Due 23 November 2002
Resolved 29 October 2002
Fire Fighting › Automatic Sprinkler System
Issued 18 October 2002 Resolved
Prove proper operation of sprinkler pump local control. LEGACY COMPONENT DESC: Pump
Due 23 November 2002
Resolved 29 October 2002
Fire Fighting › Structural - A Class Divisions
Issued 18 October 2002 Resolved
Remove holdback on fire door leading to bridge LEGACY COMPONENT DESC: Openings - Fire Doors
Due 30 October 2002
Resolved 29 October 2002
Fire Fighting › Automatic Sprinkler System
Issued 18 October 2002 Resolved
Test sprinkler hose.
Due 30 November 2002
Resolved 29 October 2002
Lifesaving › Launching Appliances
Issued 18 October 2002 Resolved
Prove proper operation of forward limit switch on port lifeboat.
Due 29 November 2002
Resolved 9 November 2002
Resolution: Switch renewed. Witnessed proper operation.
Lifesaving › Launching Appliances
Issued 18 October 2002 Resolved
Demonstrate proper automatic feed of lifeboat release system. LEGACY COMPONENT DESC: Release Mechanism
Due 29 November 2002
Resolved 9 November 2002
Resolution: Vessel crew serviced cable pulleys. No additional weight needed. Witnessed proper operation.
Lifesaving › Embarkation Appliances/Stations
Issued 18 October 2002 Resolved
Provide embarkation ladders that comply with 46 CFR Subchapter W reqmt for length of ladder to accomodate 15 degree list.
Due 29 November 2002
Resolved 9 November 2002
Resolution: New ladders on board.
Communications › Internal Communications System
Issued 18 October 2002 Resolved
Provide adequate public address system that complies with 46CFR113.50. Should be heard throughout vessel especially in accommodation spaces.
Due 29 December 2002
Resolved 9 November 2002
Resolution: Public Address system to supplement General Alarm working as designed, no modifications since installation/acceptance. Meets the requirements of 46CFR sub chapters U, W, J.
Lifesaving
Issued 15 August 1999 Resolved
PRIOR TO DEPARTING SHIPYARD TALCAHUANO, CHILE CONDUCT 1.1 MAX CAPACITY LIFEBOAT RELEASING GEAR/WEIGHT TEST ON PORT AND STBD LIFEBOAT AND RESCUE BOAT. FAX SHIPS LOG ENTRY W/CAPTAINS SIGNATURE TO [phone withheld].
Condition: Unknown
Due 19 August 1999
Resolved 23 August 1999
Unknown
Issued 15 August 1999 Resolved
PRIOR TO DEPARTING NEW ZEALAND/INTO THE ICE, RENEW THREE (3) MAIN SEA STRAINERS. TEMP REPAIRS AUTHORIZED UNTIL REPLACEMENTS ARE INSTALLED.
Condition: Unknown
Due 15 August 1999
Resolved 15 August 1999
Documentation
Issued 22 July 1995 Resolved
At next U.S. port, provide FCC Safety Certificate.
Condition: Unknown
Due 22 July 1995
Resolved 22 July 1995
Lifesaving
Issued 22 July 1995 Resolved
Properly service vessels liferafts prior to 17 September 1995.
Condition: Unknown
Due 22 July 1995
Resolved 22 July 1995
Fire Fighting
Issued 22 July 1995 Resolved
Submit for approval plans to modify the incinerator room fixed fire ext. sys. to correct the problem of free communication between incinerator room and boiler room so that if CO2 is discharged it is contained in the incinerator room.
Condition: Unknown
Due 22 July 1995
Resolved 22 July 1995
Fire Fighting
Issued 22 July 1995 Resolved
Provide fire fighting foam test certificate.
Condition: Unknown
Due 22 July 1995
Resolved 22 July 1995
Engineering
Issued 22 July 1995 Resolved
Submit for CG approval plans detailing the installation of an automatic shutdown device for the emergency diesel generator upon release of the fixed CO2 extinguishing system. System shall be installed after CG approvalin accordance with approved plans.
Condition: Unknown
Due 22 July 1995
Resolved 22 July 1995
Fire Fighting
Issued 22 July 1995 Resolved
Retest CO2 cylinders listed on Gas Cylinder Test Report Job no. 6101 and 6102 from Wormald New Zealand Limited at an approved U.S. DOT test facilityin accordance with 46 CFR 147.65.
Condition: Unknown
Due 22 July 1995
Resolved 22 July 1995
Electrical
Issued 15 June 1994 Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAY ON #2 SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Engineering
Issued 6 August 1993 Resolved
RENEW BLANKETS ON EXHAUST FLANGES ABOVE MANIFOLD ON ALL MAIN ENGINES EXCEPTSTARBOARD INBOARD.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Electrical
Issued 6 August 1993 Resolved
REPAIR GROUND ON EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Engineering
Issued 17 May 1993 Resolved
PROVIDE EVIDENCE OF MSC APPROVAL OF THE AUTOMATION VITAL SYSTEMS TO THE COGNIZANT OCMI.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Engineering
Issued 17 May 1993 Resolved
COMPLETE SATISFACTORY DESIGN VERIFICATION TESTING AND SUBMIT PERIODIC TEST PROCEEDURES TO COGNIZANT OCMI.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Construction/Loadline
Issued 12 May 1993 Resolved
MODIFY BALLAST MANIFOLD AND PIPING SYSTEM TO BRING INTO COMPLIANCE WITH 46CFR 56.50-50(h). APPROVED PLANS MUST ALSO BE PROVIDED.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 1 March 1992 Resolved
PROVIDE COAST GUARD APPROVAL CERTIFICATE FOR RESCUE BOAT OR REMOVE AND INSTALL AN APPROVED UNIT.
Condition: Unknown
Due 1 March 1992
Resolved 1 March 1992
Lifesaving
Issued 1 March 1992 Resolved
PROVIDE COAST GUARD APPROVAL CERTIFICATE FOR RESCUE BOAT WINCH OR REMOVE AND INSTALL APPROVED UNIT.
Condition: Unknown
Due 1 March 1992
Resolved 1 March 1992
Lifesaving
Issued 1 March 1992 Resolved
PROVIDE COAST GUARD APPROVAL CERTIFICATE FOR RESCUE BOAT DAVIT OR REMOVE AND INSTALL APPROVED UNIT.
Condition: Unknown
Due 1 March 1992
Resolved 1 March 1992

Casualty record · 1

15 May 2014Routine · role: Involved in a Marine Casualty · activity 4862348
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.