MAURY USCG vessel records Sign in
← All vessels

SILVER HORN

SILVER HORN is a 1990 freight ship. The Coast Guard has recorded 31 inspections since 1992, most recently in July 2008, along with 13 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 1992 to 2008. Most recent: inspection, 14 July 2008.

Built
1990
Last inspected
14 July 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8907204 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
370433
Flag
LIBERIA
—
Maury page id
psix-370433

Inspections, by type

…with no type recorded25
Years with a record 13 calendar years (1992–2008)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3588 - Regulatory (Subpart C or D), Net Ton
6807 - Dead Weight, Ton
6419 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

14 July 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3256623
16 November 2004 Random ISPS/MTSA/PSC
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2241838
19 July 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2137881
1 June 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2084573
10 November 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1945428
20 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1760057
11 December 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1717386
3 January 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1481319
4 October 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 294192
10 November 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 434480
9 June 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 416599
2 March 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 468921
9 December 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 525907
14 October 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 525678
10 June 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 404501
23 January 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 399943
30 May 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 391718
20 February 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 200733
20 February 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753914
26 January 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 374664
11 January 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 374167
29 April 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 366598
3 May 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 682856
9 April 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 168605
8 April 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 357495
20 November 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 354547
10 August 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 352443
29 July 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 682854
28 July 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 352177
11 June 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 698264
20 January 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 348246

Deficiency record · 13

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 July 2008 No resolution recorded
Vessel has not prepared or submitted a Non-Tank Vessel Response plan to the United States Coast Guard IAW the United States Federal Water Pollution Control Act as amended by section 701 & The Coast Guard Maritime Transporttation Act of 2004.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation
Issued 4 October 2001 Resolved
Observed plastics mixed with food waste in galley containers and in final separation containers on deck. Noted plastics in container labeled "food waste". Also not in compliance with garbage management plan. 33CFR 151.67 &57/ MARPOL annex V.
Condition: Unknown
Due 4 October 2001
Resolved 29 November 2001
Engineering
Issued 4 October 2001 Resolved
Noted #8 condenser in engine room to be in poor & wasted condition and readily releasing steam into engine space. Hazard to personnel. Class to inspect and provide report of survey attesting to condition and correction.SOLAS 74/78 II/1/26
Condition: Unknown
Due 19 October 2001
Resolved 3 January 2002
Resolution: CLASS REPORT WAS RECIEVED CLEARING DEFICIENCY.
Engineering
Issued 4 October 2001 Resolved
Oil record book entries and on site inspection indicate incinerator non- operative. Repair to the satisfaction of class, or class to ammend IOPP Supplement. MARPOL Annex I/REG 8.
Condition: Unknown
Due 19 October 2001
Resolved 3 January 2002
Resolution: CLASS REPORT WAS RECIVED CLEARING DEFICIENCY.
Fire Fighting
Issued 4 October 2001 Resolved
Repair fire door to engine room control room, also noted that main accomodation fire doors are poorly fitted and have visible gaps around 3/4 of door edge. Class to provide report of survey and attest to correction NLT 19OCY01. SOLAS 74/78 II/2/30.
Condition: Unknown
Due 19 October 2001
Resolved 3 January 2002
Resolution: CLASS REPORT WAS RECIVED CLEARING DEFICIENCY.
Documentation
Issued 4 October 2001 Resolved
SOPEP to be updated with current list of emergency contact numbers. MARPOL Annex I/ 33CFR 151.26
Condition: Unknown
Due 4 October 2001
Resolved 5 October 2001
Electrical
Issued 4 October 2001 Resolved
Repair exhaust ventilation curtain for emergency generator. Noted to be separated allowing excessive exhaust to dump into emergency generator_x001C_ space. Class to provide report of survey attesting to correciton. SOLAS 74/78 II/1/35
Condition: Unknown
Due 19 October 2001
Resolved 3 January 2002
Resolution: CLASS REPORT WAS RECIEVED CLEARING DEFICEINCY
Lifesaving
Issued 10 November 1999 Resolved
IN THAT THE VESSEL'S RADAR TRANSPONDER'S BATTERIES HAD EXPIRED. _x001C_ SOLAS 74/78 CHAP III REG 19.2
Condition: Unknown
Due 11 November 1999
Resolved 11 November 1999
Lifesaving
Issued 10 November 1999 Resolved
IN THAT THE VESSEL'S PORTSIDE LIGHT AND SMOKE FLOAT WAS EXPIRED. _x001C_ SOLAS 74/78 CHAP III REG 19.2
Condition: Unknown
Due 11 November 1999
Resolved 11 November 1999
Navigation
Issued 30 May 1996 Resolved
PRIOR TO NEXT U.S. PORT, MAKE REPAIRS TO GMDSS, SOLAS APPROVED, VHF HANDHELD RADIO, AS REQUIRED BY VSL'S SOLAS SAFETY CERTIFICATE.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Navigation
Issued 11 January 1995 Resolved
MAGNETIC COMPASS NOT PROPERLY ILLUMINATED.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Navigation
Issued 11 January 1995 Resolved
TIDAL CURRENT TABLES MISSING
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 28 July 1992 Resolved
THE VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.