Inspection history · 25
6 October 2021
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7327625
5 February 2020
Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6904925
26 September 2019
In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6822570
10 August 2019
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6783148
12 July 2019
Attraction Vessel Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6747189
27 June 2019
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6727730
23 May 2019
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6690455
19 September 2018
In-Service Inspection · Hull Examination · Deficiency Check · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6545464
30 March 2018
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6384055
21 February 2018
Deficiency Check · In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6361191
1 February 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6558699
26 January 2018
In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6345949
4 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6317841
1 December 2017
Hull Examination · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6316474
10 November 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6307244
22 August 2017
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6248553
16 August 2017
In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6244581
25 June 2017
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6187157
21 June 2017
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6182118
23 May 2017
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6155023
23 February 2017
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6093919
8 November 2016
Drydock Exam · In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6038757
25 July 2016
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5952120
6 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5931770
13 June 2016
COI Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5902975
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 26 September 2019
Resolved
Vessel stability authorizes daylight only. The COI authorizes day and night. We have put in an inquire to MSC, waiting on information to come back. Vessel is limited to daylight only IAW the Stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 30 September 2019
Resolution: Ammended COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 June 2019
Resolved
Make all gauges at op staion operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2019
Resolved 17 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 June 2019
Resolved
Vessel is missing lifejacket placard. Renew/replace placard prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 17 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 14 June 2019
Resolved
Remove all dead end wiring
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 27 June 2019
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 June 2019
Resolved
Replace 01 fire buckets
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 17 June 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 June 2019
Resolved
Remove all plastic zip ties from engine space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 27 June 2019
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2018
Resolved
All noted areas for repair are to be cut out to good metal and all steel repairs are to be completed using guidance found in NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2019
Resolved 12 March 2019
Resolution: All Steel repairs were completed.
Construction/Loadline › Hull › Bottom Plating
Issued 1 December 2017
Resolved
Crop and renew a minimum of 18" x 18" on the port side below the first scupper, approx. 17.5' from the bobstay and approximately 1' below the weld transition to .250 lower hull plating. Area is marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 March 2019
Resolution: Crop and renew complete.
Construction/Loadline › Hull › Bottom Plating
Issued 1 December 2017
Resolved
Crop and renew minimum of 18" x 18" the area on the port side below the thrid scupper approximately 30.5' aft of the bobstay shackle and approx. 2' below the weld seam transition to .250 lower hull plate. Area is marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 March 2019
Resolution: Crop and renew complete
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2017
Resolved
Crop and renew minimum of 18" x 18" the area on the stbd side below the first scupper approximately 17.5' from the bobstay shackle and approximately 2' below the weld seam transition to .250 lower hull plate. Area is marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 March 2019
Resolution: Crop and renew complete.
Sail Rigging › Running Rigging › Blocks
Issued 10 November 2017
No resolution recorded
Provide a Preventative Maintenance Plan and General Inventory for all Sails and Rigging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2018 — due date passed with no resolution recorded
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 10 November 2017
Resolved
Provide seizings on bowsprit shroud turnbuckles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 14 June 2019
Sail Rigging › Spars › Tangs
Issued 10 November 2017
Resolved
Remove all corrosion from port side of bowsprit at the deck edge transition to bare metal for further examination.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 14 June 2019
Sail Rigging › Mast Step › Mast Partners
Issued 10 November 2017
Resolved
Re-install all mast wedges at deck housing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 28 May 2019
Sail Rigging › Chainplates › Materials
Issued 10 November 2017
Resolved
Provide for adequate access to both mast steps for further examination.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 12 March 2019
Resolution: Several chain plates were exposed, previously covered in foam. All SAT.
Sail Rigging › Chainplates › Materials
Issued 10 November 2017
Resolved
Provide for access to chain plates for further examination.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 March 2019
Resolution: Several chain plates were exposed, previously covered in foam. All SAT.
Sail Rigging › Deck Hardware › Shackles
Issued 10 November 2017
Resolved
The forward leg of the port fore shroud is connected with an undersized turnbuckle. Renew with appropriate sized turnbuckle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 14 June 2019
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 November 2017
Resolved
Reattach ratboards to provide for even spacing while going aloft. (15" standard).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 14 June 2019
Sail Rigging › Stays/Shrouds › Wires
Issued 10 November 2017
Resolved
Renew fore peak halyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 23 May 2019
Sail Rigging › Spars › Gaffs/Jaws/Saddles/Fittings
Issued 10 November 2017
Resolved
Make permanent repair to checking in the main gaff topside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 21 February 2018
Resolution: Repairs completed satisfactorily
Sail Rigging › Stays/Shrouds › Wires
Issued 10 November 2017
Resolved
Make adjustment to masts/rig to ensure main topmast stay is not bearing the forward load of the lower main mast. (tune rig)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 14 June 2019
Sail Rigging › Stays/Shrouds › Wires
Issued 10 November 2017
Resolved
End for end or replace the throat halyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 14 June 2019
Sail Rigging › Spars › Gaffs/Jaws/Saddles/Fittings
Issued 10 November 2017
Resolved
Make permanent repairs to the check/glue joint at the main gaff jaw.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 21 February 2018
Resolution: Repairs completed satisfactorily.
Construction/Loadline › Hull › Hull Plating
Issued 16 August 2017
Resolved
Provide gauging report for those areas marked on the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 11 November 2017
Resolution: Gaugings of the hull completed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2017
Resolved
Provide current copy of Coast Pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 4 December 2017
Resolution: Received receipt for Coast Pilot.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2017
Resolved
Provide current copy of the CG Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 4 December 2017
Resolution: Received receipt for light list.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2017
Resolved
Provide current copy of COLREGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 4 December 2017
Resolution: Received receipt for navigation rules.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2017
Resolved
Provide current/updated charts for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Engineering › Bilge Water Management System › Pump
Issued 16 August 2017
Resolved
Prove proper operation of all bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Engineering › Bilge Water Management System › Not Operational
Issued 16 August 2017
Resolved
Prove proper operation of high water bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 18 August 2017
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 16 August 2017
No resolution recorded
Provide check valves for overboard discharges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 16 August 2017
Resolved
Provide positive means to prevent overboard discharge while operating in Designated No Discharge Zones in the Great Lakes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Stability › Watertight Integrity › General
Issued 16 August 2017
Resolved
Make proper repairs to aft hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 16 August 2017
Resolved
Provide Third Party Sail Rigging Inspection and Maintenance Plan.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 30 November 2017
Resolution: Third party rigging survey completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2017
Resolved
Remove or properly end all dead end wiring.
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 23 May 2019
Electrical › Electric Supply System (service) › Battery Charger
Issued 16 August 2017
Resolved
Prove preoper operation of battery charging system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 23 May 2019
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 August 2017
Resolved
Provide proper maintenance of batteries in accordance with the manufacturer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2017
Resolved
Provide report addressing stray current issue.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 23 May 2019
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 16 August 2017
Resolved
Prove proper operation of the emergency steering system.
Condition: Improper Installation
Due 16 February 2018
Resolved 14 June 2019
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2017
Resolved
Secure excess wiring in a suitable manner.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 4 December 2017
Resolution: Redundant requirement; already addressed in another deficiency.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 August 2017
Resolved
Provide storage of life jackets to make them readily available.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Engineering › Fuel Oil Service System › Pump
Issued 25 June 2017
Resolved
Fuel pump is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2017
Resolved 1 July 2017
Resolution: Satisfactory test of MDE, deficiency was cleared.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 June 2016
Resolved
Make permanent repairs to overboard raw water discharge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2016
Resolved 20 June 2016
Resolution: O/O replaced leaking exhaust hose.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 June 2016
Resolved
Stern navigational light extinguished.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 14 June 2016
Resolution: On the spot replacement/correction.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 13 June 2016
Resolved
Post emergency instructions at the operation station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 25 July 2016
Resolution: Emergency Instructions Posted.
Operations/Management › Passenger Operations › Safety Orientation
Issued 13 June 2016
Resolved
Properly mark emergency exits on main deck side with "emergency exit, keep clear"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 25 July 2016
Resolution: Emergency Exits marked.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 13 June 2016
Resolved
Provide marking at stove fuel shutoff location to include direction of valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 25 July 2016
Resolution: Fuel Shutoff direction of shutoff marked.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2016
Resolved
Provide visual indication at operation station for high bilge level alarms.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 25 July 2016
Resolution: High bilge level alarms operating properly at ops station.
Accommodation/Occupational Safety › Messroom › Location
Issued 13 June 2016
Resolved
Provide exhaust with lagging in galley area for diesel stove prior to operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 25 July 2016
Resolution: Lagging and piping re-installed.
Navigation › Piloting/Steering › Marine Charts
Issued 13 June 2016
Resolved
Provide current and corrected charts for area of operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 20 June 2016
Resolution: O/O purchased new charts for the area of operations.
Sail Rigging › Mast Step › Base
Issued 13 June 2016
Resolved
Provide shroud/cover at main deck interface to ensure coverage over wedge end grain on forward mast.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 25 July 2016
Resolution: Shroud cover installed over fore mast base.