MAURY USCG vessel records Sign in
← All vessels

APPLEDORE V

APPLEDORE V is a 1992 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1992, most recently in October 2021, along with 85 deficiencies — 2 with no resolution recorded —.

Records from 1992 to 2021. Most recent: inspection, 6 October 2021.

Built
1992
Last inspected
6 October 2021
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB2886
370516
Flag
UNITED STATES
366881060 (licence lapsed)
Maury page id
psix-370516

Inspections, by type

…with no type recorded2
…past their stated due date2
Years with a record 27 calendar years (1992–2021)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.0 ft × 14.0 ft × 8.6 ft
Registered tonnagegross 34 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTREWORGY YACHTS INC · PALM COAST, FL, UNITED STATES · built 1992
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portBAY CITY, MI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH4606MMSI 366881060 · expired · compulsorily equipped · granted 7 May 2014, cancelled 13 July 2024
WDB2886MMSI 366881060 · expired · compulsorily equipped · granted 7 February 2003, cancelled 13 April 2013
WCZ6607MMSI not assigned · expired · compulsorily equipped · granted 8 February 2000, cancelled 10 April 2010 · licensed under a name not among this hull’s recorded names (not shown)
WCJ8310MMSI not assigned · expired · voluntarily equipped · granted 18 July 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 71

6 October 2021 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7327625
5 February 2020 Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6904925
26 September 2019 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6822570
10 August 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6783148
12 July 2019 Attraction Vessel Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6747189
27 June 2019 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6727730
23 May 2019 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6690455
19 September 2018 In-Service Inspection · Hull Examination · Deficiency Check · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6545464
30 March 2018 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6384055
21 February 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6361191
1 February 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6558699
26 January 2018 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6345949
4 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6317841
1 December 2017 Hull Examination · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6316474
10 November 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6307244
22 August 2017 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6248553
16 August 2017 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6244581
25 June 2017 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6187157
21 June 2017 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6182118
23 May 2017 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6155023
23 February 2017 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6093919
8 November 2016 Drydock Exam · In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6038757
25 July 2016 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5952120
6 July 2016 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5931770
13 June 2016 COI Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5902975
24 June 2014 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4898316
14 May 2014 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4886638
13 June 2012 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4343441
6 June 2012 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4342151
11 January 2012 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4223215
12 December 2011 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4206718
27 September 2011 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4161023
9 September 2011 Attraction Vessel Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4150967
29 November 2010 In-Service Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3893305
29 September 2010 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3859402
25 June 2008 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3214273
17 June 2008 Attraction Vessel Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3291579
15 May 2008 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3308681
5 June 2007 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2952210
8 August 2006 Attraction Vessel Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2740535
7 August 2006 Attraction Vessel Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2738912
6 June 2006 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2594611
3 May 2005 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2344386
9 September 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2190993
25 August 2004 Type not recorded
No type recorded · Station South Portland · USCG Northeast District (CGD-NE) · Activity 2176643
14 July 2004 Administrative Inspection
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2132660
21 May 2004 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2203941
19 August 2003 In-Service Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1881013
5 June 2003 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1827436
25 April 2003 Administrative Inspection
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1780583
20 June 2002 Annual Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1633671
4 June 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1461410
1 May 2000 COI Inspection · Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1369700
29 October 1999 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1448037
15 October 1999 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1122428
7 June 1999 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1378710
6 April 1998 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1436063
30 October 1997 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 782712
30 October 1997 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 782713
27 May 1997 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1107552
14 May 1997 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1448909
4 October 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1142133
3 July 1996 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1084537
14 November 1995 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 873495
23 October 1995 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1192330
19 May 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1198732
22 April 1994 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 858395
17 May 1993 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 827424
3 June 1992 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1256121
21 May 1992 Inclining Experiment · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 952468
16 April 1992 Hull Examination · Initial Certification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1258671

Deficiency record · 85

01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 26 September 2019 Resolved
Vessel stability authorizes daylight only. The COI authorizes day and night. We have put in an inquire to MSC, waiting on information to come back. Vessel is limited to daylight only IAW the Stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 30 September 2019
Resolution: Ammended COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 June 2019 Resolved
Make all gauges at op staion operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2019
Resolved 17 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 June 2019 Resolved
Vessel is missing lifejacket placard. Renew/replace placard prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 17 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 14 June 2019 Resolved
Remove all dead end wiring
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 27 June 2019
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 June 2019 Resolved
Replace 01 fire buckets
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 17 June 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 June 2019 Resolved
Remove all plastic zip ties from engine space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 27 June 2019
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2018 Resolved
All noted areas for repair are to be cut out to good metal and all steel repairs are to be completed using guidance found in NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2019
Resolved 12 March 2019
Resolution: All Steel repairs were completed.
Construction/Loadline › Hull › Bottom Plating
Issued 1 December 2017 Resolved
Crop and renew a minimum of 18" x 18" on the port side below the first scupper, approx. 17.5' from the bobstay and approximately 1' below the weld transition to .250 lower hull plating. Area is marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 March 2019
Resolution: Crop and renew complete.
Construction/Loadline › Hull › Bottom Plating
Issued 1 December 2017 Resolved
Crop and renew minimum of 18" x 18" the area on the port side below the thrid scupper approximately 30.5' aft of the bobstay shackle and approx. 2' below the weld seam transition to .250 lower hull plate. Area is marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 March 2019
Resolution: Crop and renew complete
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2017 Resolved
Crop and renew minimum of 18" x 18" the area on the stbd side below the first scupper approximately 17.5' from the bobstay shackle and approximately 2' below the weld seam transition to .250 lower hull plate. Area is marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 March 2019
Resolution: Crop and renew complete.
Sail Rigging › Running Rigging › Blocks
Issued 10 November 2017 No resolution recorded
Provide a Preventative Maintenance Plan and General Inventory for all Sails and Rigging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2018 — due date passed with no resolution recorded
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 10 November 2017 Resolved
Provide seizings on bowsprit shroud turnbuckles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 14 June 2019
Sail Rigging › Spars › Tangs
Issued 10 November 2017 Resolved
Remove all corrosion from port side of bowsprit at the deck edge transition to bare metal for further examination.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 14 June 2019
Sail Rigging › Mast Step › Mast Partners
Issued 10 November 2017 Resolved
Re-install all mast wedges at deck housing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 28 May 2019
Sail Rigging › Chainplates › Materials
Issued 10 November 2017 Resolved
Provide for adequate access to both mast steps for further examination.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 12 March 2019
Resolution: Several chain plates were exposed, previously covered in foam. All SAT.
Sail Rigging › Chainplates › Materials
Issued 10 November 2017 Resolved
Provide for access to chain plates for further examination.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 12 March 2019
Resolution: Several chain plates were exposed, previously covered in foam. All SAT.
Sail Rigging › Deck Hardware › Shackles
Issued 10 November 2017 Resolved
The forward leg of the port fore shroud is connected with an undersized turnbuckle. Renew with appropriate sized turnbuckle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 14 June 2019
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 November 2017 Resolved
Reattach ratboards to provide for even spacing while going aloft. (15" standard).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 14 June 2019
Sail Rigging › Stays/Shrouds › Wires
Issued 10 November 2017 Resolved
Renew fore peak halyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 23 May 2019
Sail Rigging › Spars › Gaffs/Jaws/Saddles/Fittings
Issued 10 November 2017 Resolved
Make permanent repair to checking in the main gaff topside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 21 February 2018
Resolution: Repairs completed satisfactorily
Sail Rigging › Stays/Shrouds › Wires
Issued 10 November 2017 Resolved
Make adjustment to masts/rig to ensure main topmast stay is not bearing the forward load of the lower main mast. (tune rig)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 14 June 2019
Sail Rigging › Stays/Shrouds › Wires
Issued 10 November 2017 Resolved
End for end or replace the throat halyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 14 June 2019
Sail Rigging › Spars › Gaffs/Jaws/Saddles/Fittings
Issued 10 November 2017 Resolved
Make permanent repairs to the check/glue joint at the main gaff jaw.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 21 February 2018
Resolution: Repairs completed satisfactorily.
Construction/Loadline › Hull › Hull Plating
Issued 16 August 2017 Resolved
Provide gauging report for those areas marked on the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 11 November 2017
Resolution: Gaugings of the hull completed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2017 Resolved
Provide current copy of Coast Pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 4 December 2017
Resolution: Received receipt for Coast Pilot.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2017 Resolved
Provide current copy of the CG Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 4 December 2017
Resolution: Received receipt for light list.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2017 Resolved
Provide current copy of COLREGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 4 December 2017
Resolution: Received receipt for navigation rules.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2017 Resolved
Provide current/updated charts for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Engineering › Bilge Water Management System › Pump
Issued 16 August 2017 Resolved
Prove proper operation of all bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Engineering › Bilge Water Management System › Not Operational
Issued 16 August 2017 Resolved
Prove proper operation of high water bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 18 August 2017
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 16 August 2017 No resolution recorded
Provide check valves for overboard discharges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 16 August 2017 Resolved
Provide positive means to prevent overboard discharge while operating in Designated No Discharge Zones in the Great Lakes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Stability › Watertight Integrity › General
Issued 16 August 2017 Resolved
Make proper repairs to aft hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 16 August 2017 Resolved
Provide Third Party Sail Rigging Inspection and Maintenance Plan.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 30 November 2017
Resolution: Third party rigging survey completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2017 Resolved
Remove or properly end all dead end wiring.
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 23 May 2019
Electrical › Electric Supply System (service) › Battery Charger
Issued 16 August 2017 Resolved
Prove preoper operation of battery charging system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 23 May 2019
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 August 2017 Resolved
Provide proper maintenance of batteries in accordance with the manufacturer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2017 Resolved
Provide report addressing stray current issue.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 23 May 2019
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 16 August 2017 Resolved
Prove proper operation of the emergency steering system.
Condition: Improper Installation
Due 16 February 2018
Resolved 14 June 2019
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2017 Resolved
Secure excess wiring in a suitable manner.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 4 December 2017
Resolution: Redundant requirement; already addressed in another deficiency.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 August 2017 Resolved
Provide storage of life jackets to make them readily available.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 14 June 2019
Engineering › Fuel Oil Service System › Pump
Issued 25 June 2017 Resolved
Fuel pump is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2017
Resolved 1 July 2017
Resolution: Satisfactory test of MDE, deficiency was cleared.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 June 2016 Resolved
Make permanent repairs to overboard raw water discharge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2016
Resolved 20 June 2016
Resolution: O/O replaced leaking exhaust hose.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 June 2016 Resolved
Stern navigational light extinguished.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 14 June 2016
Resolution: On the spot replacement/correction.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 13 June 2016 Resolved
Post emergency instructions at the operation station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 25 July 2016
Resolution: Emergency Instructions Posted.
Operations/Management › Passenger Operations › Safety Orientation
Issued 13 June 2016 Resolved
Properly mark emergency exits on main deck side with "emergency exit, keep clear"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 25 July 2016
Resolution: Emergency Exits marked.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 13 June 2016 Resolved
Provide marking at stove fuel shutoff location to include direction of valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 25 July 2016
Resolution: Fuel Shutoff direction of shutoff marked.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2016 Resolved
Provide visual indication at operation station for high bilge level alarms.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 25 July 2016
Resolution: High bilge level alarms operating properly at ops station.
Accommodation/Occupational Safety › Messroom › Location
Issued 13 June 2016 Resolved
Provide exhaust with lagging in galley area for diesel stove prior to operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 25 July 2016
Resolution: Lagging and piping re-installed.
Navigation › Piloting/Steering › Marine Charts
Issued 13 June 2016 Resolved
Provide current and corrected charts for area of operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 20 June 2016
Resolution: O/O purchased new charts for the area of operations.
Sail Rigging › Mast Step › Base
Issued 13 June 2016 Resolved
Provide shroud/cover at main deck interface to ensure coverage over wedge end grain on forward mast.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 25 July 2016
Resolution: Shroud cover installed over fore mast base.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 May 2014 Resolved
Label alarm indicators at operating station.
Due 21 May 2014
Resolved 21 May 2014
Resolution: Inidcators are appropriately labeled.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 May 2014 Resolved
Conduct emergency steering drill with crew.
Due 21 May 2014
Resolved 21 May 2014
Resolution: Drills were conducted and logged.
Lifesaving › Hand Flares › Expired
Issued 14 May 2014 Resolved
Dispose of expired flares.
Due 21 May 2014
Resolved 21 May 2014
Resolution: Expired flares were exposed of.
Electrical › Electric Supply System (service) › Cable
Issued 14 May 2014 Resolved
Install proper wire bracketing in engine compartment
Due 21 May 2014
Resolved 21 May 2014
Resolution: Wiring has been properly bracketed.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 29 November 2010 Resolved
Provide proof of current contract with an approved drug consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2010
Resolution: Vessel has onboard current contract with drug consortium with crew listed.
Navigation › Piloting/Steering › Marine Charts
Issued 29 November 2010 Resolved
Provide up to date charts and nautical publications IAW 46 CFR 185.20-35 (NO CITE AVAILABLE)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2010
Resolution: Vessel has onboard current nautical charts and publications.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 29 November 2010 Resolved
Provide an FCC safety radiotelephony certificate.
Action required: 705 - Other - as specified
Resolved 6 December 2010
Resolution: Vessel has current FCC safety radiotelephony certificate.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 November 2010 Resolved
Provide an approved first aid kit.
Due 13 December 2010
Resolved 6 December 2010
Resolution: First aid kit is onboard, all SAT.
Engineering › Freshwater System (intermediary cooling) › Hose
Issued 29 November 2010 Resolved
Replace fleible hose on discharge side of red gear cooler IAW 46 CFR 182.40-1 (d). (NO CITE AVAILABLE)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2010
Resolved 6 December 2010
Resolution: Flexible hose has been replaced on discharge side of reduction gear cooler.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 29 November 2010 Resolved
Provide alcohol test kits onboard prior to operating beyond two hours from the pier.
Action required: 705 - Other - as specified
Due 24 January 2011
Resolved 24 January 2011
Resolution: Alcohol swabs onboard.
Lifesaving › Launching Appliances › Release Mechanism
Issued 20 June 2002 Resolved
Proivde a hydrostatic release unit for the life floats prior to operations.
Condition: Improper/Lack of Maintenance
Due 20 June 2002
Resolved 20 June 2002
Lifesaving
Issued 4 June 2001 Resolved
Provide two (2) paddles for each life-float prior to carrying passengers and prior to the compliance date.
Condition: Unknown
Due 15 June 2001
Resolved 12 June 2001
Lifesaving
Issued 1 May 2000 Resolved
Provide and install waterlights and paddles for three (3) life floats priorto carrying passengers and prior to the compliance date.
Condition: Unknown
Due 8 May 2000
Resolved 6 June 2000
Fire Fighting
Issued 1 May 2000 Resolved
Provide three (3) 2.5 gallon fire buckets prior to carrying passengers and prior to the compliance date.
Condition: Unknown
Due 8 May 2000
Resolved 6 June 2000
Lifesaving
Issued 1 May 2000 Resolved
Conduct a man overboard and fire fighting drill prior to the compliance date.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Lifesaving
Issued 1 May 2000 Resolved
Provide and post lifejacket donning placard prior to carrying passengers and prior to the compliance date.
Condition: Unknown
Due 8 May 2000
Resolved 6 June 2000
Unknown
Issued 7 June 1999 Resolved
VESSEL IS TO CONDUCT UNDERWAY DRILLS PRIOR TO CARRYING PASSENGERS. THIS REQUIREMENT IS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Lifesaving
Issued 14 May 1997 Resolved
Provide a USCG approved First Aid kit on board.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Documentation
Issued 14 May 1997 Resolved
Provide proper documentation of fully compliant chemical testing program; _x001C_a) Copy of contract, b) dates of employment, c) Employee Assistance Plan. _x001C_Marine Employer is not authorized to operate after 14JUN97 unless this requirement has been cleared to the satisfaction of an attending USCG (con)
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Documentation
Issued 14 May 1997 Resolved
(con't) Marine Inspector.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Lifesaving
Issued 3 July 1996 Resolved
CONDUCT MAN OVERBOARD DRILL
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Engineering
Issued 3 July 1996 Resolved
CLAMP FUEL RETURN LINE AND PROVIDE CHAFING GEAR TO SAME.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Fire Fighting
Issued 3 July 1996 Resolved
PROVIDE 2 ADDITIONAL BII FIRE EXTINGUISHERS PRIOR TO CARRYING PASSENGERS AND NOT LATER THAN 10 JULY 96
Condition: Unknown
Due 10 July 1996
Resolved 26 July 1996
Documentation
Issued 3 July 1996 Resolved
PROVIDE DOCUMENTATION VERIFYING COMPLIANCE WITH DRUG TESTING PROGRAM
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Lifesaving
Issued 3 July 1996 Resolved
PROVIDE BRIGHTLY COLORED DISTRESS FLARE BOX
Condition: Unknown
Due 3 August 1996
Resolved 26 July 1996
Documentation
Issued 3 July 1996 Resolved
PROVIDE FCC EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 3 August 1996
Resolved 26 July 1996
Documentation
Issued 3 July 1996 Resolved
PROVIDE GARBAGE DISCHARGE PLACARD
Condition: Unknown
Due 3 August 1996
Resolved 26 July 1996
Construction/Loadline
Issued 23 October 1995 Resolved
REPLACE ALL ZINC PLATES, EXCEPT RUDDER ZINCS._x001C_ _x001C_
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Navigation
Issued 23 October 1995 Resolved
REFASTEN LOOSE FORWARD MAST LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Lifesaving
Issued 19 May 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 21 May 1992 Resolved
INSTALL HORN PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Navigation
Issued 21 May 1992 Resolved
INSTALL NAVIGATION LIGHTS IAW COLREGS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Electrical
Issued 21 May 1992 Resolved
PROPERLY MOUNT WIRING IN AFT COMPARTMENT, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Documentation
Issued 16 April 1992 Resolved
PRIOR TO THE CARRIAGE OF MORE THAN SIX (6) PASSENGERS COMPLETE INSPECTION FOR CERTIFICATION TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION (OCMI) BUT IN NO CASE LATER THAN 16 OCTOBER 1992.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.