BAREFOOT IV is a 1992 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1992, most recently in March 2026, along with 148 deficiencies, 2 operational controls and 1 casualty investigation in 2012.

Records from 1992 to 2026. Most recent: inspection, 11 March 2026.

Built
1992
Last inspected
11 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW7500
370993
Flag
UNITED STATES
367113010
Maury page id
psix-370993

Inspections, by type

…with no type recorded2
Years with a record 32 calendar years (1992–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 26.0 ft × 4.0 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS INC · ST CROIX USVI · built 1992
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Faired Keel)
Hull configurationTwin Hull
Hailing portSAN JUAN, PR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCW7500MMSI 367113010 · active · compulsorily equipped · granted 6 August 2026, expires 23 July 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

11 March 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8323641
1 October 2025 Drydock Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8247178
13 July 2025 Type not recorded
No type recorded · Station San Juan · USCG Southeast District (CGD-SE) · Activity 8185035
1 April 2025 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8102441
6 March 2024 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7874220
19 October 2023 Deficiency Check · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7811005
16 March 2023 Annual Inspection · Plan Review "T" Boat · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7650854
7 February 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7633403
31 January 2022 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7388283
27 January 2022 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7386550
5 November 2021 Examination of Repairs · Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7344620
29 April 2021 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7185325
27 February 2020 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6907192
6 November 2019 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6849488
28 March 2019 Annual Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6648449
12 March 2018 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6370073
25 October 2017 Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6294233
7 February 2017 COI Inspection · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6077869
29 July 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5956460
2 March 2016 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5825079
21 October 2015 Drydock Exam · Hull Examination · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5748793
19 August 2015 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5220613
3 June 2014 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4878557
5 May 2014 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4850860
28 February 2012 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4252839
6 February 2012 COI Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4239188
17 November 2010 Deficiency Check · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3886878
24 March 2010 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3702134
11 March 2010 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3696512
14 November 2008 Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3362928
5 February 2008 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3142388
7 February 2007 COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2868237
31 January 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2576526
16 November 2005 Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2536011
12 November 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2536896
3 June 2005 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2376604
23 December 2004 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2263925
24 May 2004 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2076332
4 February 2003 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1739413
23 October 2002 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1694026
26 February 2002 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1487108
25 April 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436551
23 February 2000 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1384381
3 March 1999 Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1458634
18 November 1998 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1383973
16 October 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1437475
22 July 1998 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1130573
15 April 1998 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 791205
26 February 1997 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1435896
14 November 1996 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1437173
24 April 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355797
4 March 1996 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1455336
9 January 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 880859
7 December 1995 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405819
11 April 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 844832
10 April 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1157457
6 March 1995 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355120
12 December 1994 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1396213
7 March 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1463074
13 December 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1425377
28 October 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1140865
23 August 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 846112
24 March 1993 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1359528
22 March 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1370562
27 January 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1356205
8 January 1993 Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1133025
10 April 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1260387
21 March 1992 Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 947948
19 March 1992 Initial Construction-Excluding Oversight
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1262997

Deficiency record · 148

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2026 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(2) General description of the drill scenario and training topics. The drill entries were missing descriptions of the scenario and training topics. Add the missing information to the entries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 25 March 2026
Resolution: New drill log with proper formatting was placed on board.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 11 March 2026 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The VHF-DSC radio should be properly connected to a GPS Receiver (electronic position fixing device) or have a VHF-DSC marine radio with integral GPS. The VHF-DSC radio did not display the GPS coordinates. Display the coordinates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 25 March 2026
Resolution: A new FCC radio with integrated GPS was installed and found properly working.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 18 November 2025 Resolved
The forward wooden passenger access ladder was found with multiple fractures and areas of wood rot, including exposed screws. Properly repair to the satisfaction of an attending USCG Marine Inspector. 46 CFR 177.100. Code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2025
Resolution: Corrected and repaired.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 18 November 2025 Resolved
A forward portside hatch cover, right forward from the existing window, that covers the flotation devices storage was found with wood root. Crop and renew, or replace. 46 CFR 177.100 Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 25 November 2025
Resolution: A new hatch was manufactured and installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 November 2025 Resolved
An area of wood rot was found to be starting in the forward upper cross beam bar, close to the access hatch portside side. Repair the area to stop the wood rot. 46 CFR 177.100 Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 25 November 2025
Resolution: Grinded and filled with West System.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 1 October 2025 Resolved
A wooden backing plate with 3 screws, located under deck, forward of the upper cross beam bar was found with wood rot. Crop and renew the backing plate and assess wood above this backing plate and notify the USCG Marine Inspector of findings. 46 CFR 177.100 Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 25 November 2025
Resolution: Screwed removed and wood plate was not holding anything, so it was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 March 2023 Resolved
Each ring life buoy must be marked with Type II retroreflective material. No retroreflective material was attached to the ring life buoy onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2023
Resolved 17 March 2023
Resolution: Received picture of retroreflective tape attached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 March 2023 Resolved
Each floating waterlight must be approved in accordance with 46 CFR 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. The installed battery inside the waterlight did not meet manufacturer's instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2023
Resolved 7 April 2023
Resolution: spring terminal battery was replaced with a post terminal battery
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 2 February 2022 Resolved
Supervisor did not have EAP Training Program documentation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 February 2022 Resolved
Vessel did not have first aid kit on board that met requirements.
Action required: 10 - Deficiency Rectified
Due 16 February 2022
Resolved 2 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 February 2022 Resolved
beckett lines deteriorating due to UV damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 February 2022 Resolved
Vessel did not have required clip on waterlights attached to ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 February 2022 Resolved
Port and starboard fresh water tank fills missing caps and open to elements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 February 2022 Resolved
Plug for deck penetration aft of the starboard fresh water tank fill was not secured tightly causing leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 February 2022 Resolved
starboard forward hatch cover had spacing between fram and deck. port forward hatch cover missing securing devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 February 2022 Resolved
Vessels side lights did not meet requirement of Rule 25.
Action required: 705 - Other - as specified
Due 16 February 2022
Resolved 17 March 2023
Resolution: Nav lights relocation approved by [name withheld], Walter at D7, supporting email uploaded into documents tab in vessel MISILE file.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 2 February 2022 Resolved
25% of port forward compartment dead light cover gasket detached from fram. Starboard center compartment dead light missing a securing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 2 February 2022 Resolved
Starboard side window on the the forward side of the cabin cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 February 2022 Resolved
Several cable and stanchio connection points along railing corroded. Reinstall cable railing on port and starboard sides above dagger boards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 February 2022 Resolved
Placard for lifejackets did not match model.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 2 February 2022 Resolved
Master needs FCC Marine Operators Permit as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 28 February 2022
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 2 February 2022 Resolved
Starboard side Type III holding tank missing screw top cover.
Action required: 10 - Deficiency Rectified
Due 16 February 2022
Resolved 2 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 2 February 2022 Resolved
Fire at Sea #3 change to jettision gasoline fuel tanks overboard, in the event of a fire in the vicinity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 2 March 2022
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 February 2022 Resolved
Starboard bilge system would not pump out compartments. Port and Starboard bilge connections overboard leaking.
Action required: 705 - Other - as specified
Due 16 February 2022
Resolved 28 February 2022
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 2 February 2022 Resolved
Starboard hull sink drain piping overbaord was not secured properly, leaking and easily removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 28 February 2022
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 27 January 2022 Resolved
The vessel has passed the extended deadline to conduct de-masting. Issuing 06 grace period until Feb 2 2022 for further action to be taken. The vessel is restricted from all use of sail. Vessel must be under power at all times.
Action required: 705 - Other - as specified
Due 2 February 2022
Resolved 2 March 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 December 2021 Resolved
The design, materials, and construction of masts, and standing rigging on a sailing vessel must be suitable for the intended service. Professional Rigging Report from Rigging Works dated 17DEC2021 indicates that the records indicates that rigging is at the end of its service life, and precautions should be taken when operating in strong winds (20knots or more) when deploying the main sail. Vessel is restricted from deploying the main sail while carrying passengers, when wind conditions are 20 knots or more. Vessel must be operated as a motor vessel (without sail) when winds are 20 knots or more. 46CFR177.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2022
Resolved 16 March 2023
Resolution: Mast was removed Feb 2022 and all standing rigging was replaced Feb 2022. New rigging survey completed March 15, 2023.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 December 2021 Resolved
The design, materials, and construction of masts, and standing rigging on a sailing vessel must be suitable for the intended service. Vessel owner/operator must submit to the USCG Sector San [name withheld] office an updated Rigging Preventive Maintenance Plan (PMP), in accordance with the recommendations contained in the NVIC 02-16, Enclosure (1), Section II, b. 46CFR177.330.
Action required: 705 - Other - as specified
Due 28 January 2022
Resolved 19 October 2023
Resolution: Received from vessel owner via emial the Sail & Rigging Preventive Maintenance Plan, see MISLE documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 March 2019 Resolved
To maintain watertight integrity properly install missing window on starboard side hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2019
Resolved 28 March 2019
Resolution: Window was reinstalled.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 28 March 2019 Resolved
The design, materials and construction of standing rigging on a sailing vessel must be suitable for the intended service. Observed multiple areas of wear on the main halyard line requiring replacement and a crack on forward furler at connection point. Vessel will not use the jib until annual rigging survey is satisfactorily completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2019
Resolved 1 May 2019
Resolution: Rigging was inspected by local rigger and all areas of concern were addressed.
Sail Rigging › Running Rigging › Sheets
Issued 25 October 2017 Resolved
Provide a rigging survey prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2017
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 7 February 2017 Resolved
Prove the design, contruction, and stowage of portable tanks and related fuel lines & accessories meet the requirements of ABYC H-25. The current portable tanks are Australian Certified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 7 April 2017
Resolution: The portable fuel tanks have been replaced with ABYC H-25 compatible tanks.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 February 2017 Resolved
Emergency instructions are not posted
Due 21 February 2017
Resolved 17 February 2017
Resolution: Instructions have been printed, laminated, and posted onboard.
Engineering › Bilge Water Management System › Piping
Issued 7 February 2017 Resolved
Preform CG approved modifications to the bilge system to bring the current system into compliance with CFRs. See narrative.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 7 April 2017
Resolution: Repairs were made to the system and pictures have been uploaded to MISLE to record the approved repairs.
Construction/Loadline › Structures › Superstructure
Issued 19 August 2015 Resolved
Provide a repair proposal and drawings with all details (materials and process) to address repairs on engines mount platform underneath the vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 August 2015
Resolved 20 August 2015
Resolution: Received repair proposal from vessel 3rd party contractor and plan was reviewed and approved.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 May 2014 Resolved
Provide both batteries with an approved tray.
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 8 May 2014
Resolution: a new set of battery trays were installed.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 7 May 2014 Resolved
Properly repair both fractured port & Stbdside windows.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 3 June 2014
Resolution: New windows have been installed as in kind condition.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 May 2014 Resolved
Provide the following publications: a. Light List and b. Tide Tables.
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 8 May 2014
Resolution: Both publications were placed on board the vessel.
Documentation › Certificates/Documents › FCC SSL
Issued 7 February 2012 Resolved
Provide current FCC Safety Certificate and post it accordingly.
Action required: 705 - Other - as specified
Due 8 March 2012
Resolved 28 February 2012
Resolution: Vessel Rep provided copy of the most current certificate and was scanned into MISLE Documents for reference.
Stability › Incline Test › General
Issued 7 February 2012 Resolved
Submit all newly requested stability information to Marine Safety Center in order to complete the new AAWPP verification process.
Action required: 705 - Other - as specified
Resolved 29 March 2012
Resolution: Issued a new CG 835 requesting vessel owner/oper to submit new stability calculations and passengers were reduced due to weight ratio as recommended by MSC to become effective on 9 April 2012.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 March 2010 Resolved
Replace (4) lifejackets (type 1). Vessel is restricted to no more than 41 passengers and 3 crew until total lifejackets are provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 25 April 2010
Resolution: Life jackets inspected satisfactorily.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 March 2010 Resolved
Provide proof of drug and alcohol compliance for 2 deckhands.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 25 March 2010
Resolution: Vessel provided consortium letter.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 24 March 2010 Resolved
Replace fire extinquisher by operating station.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 25 March 2010
Resolution: Extinguisher replaced.
Documentation › Markings/Placards › Lifejacket Placard
Issued 24 March 2010 Resolved
Provide proper donning instructions for all types of lifejackets onboard.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 25 March 2010
Resolution: Proper placard provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 March 2010 Resolved
Replace batteries for self igniting light and log date of replacement in maintenence log.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 29 April 2010
Lifesaving › Launching Appliances › Release Mechanism
Issued 24 March 2010 Resolved
Replace hydrostatic release for EPIRB and log date of replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2010
Resolved 25 March 2010
Resolution: A new release was installed.
Engineering › Gasoline Engine (propulsion) › Crankcase (2 stroke)
Issued 24 March 2010 Resolved
Provide two bolts for stbd side outboard engine mount.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 29 April 2010
Construction/Loadline › Structures › Superstructure
Issued 24 March 2010 Resolved
Replace one starboard side and two port side gaskets for portlights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 25 March 2010
Resolution: All portlight gaskets replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 24 March 2010 Resolved
Address drilled drain holes through transverse frames aft of heads.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 29 April 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 March 2010 Resolved
Replace/repair top step on stbd side passenger embarkation ladder.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2010
Resolution: Top step replaced satisfactorily.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 March 2010 Resolved
Vessel must ensure that all deck rails are in compliance with 46 CFR 177.900.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 7 March 2012
Resolution: Rail height was corrected to 39.5 inches as per specified in the regulation.
Construction/Loadline › Structures › Superstructure
Issued 14 November 2008 Resolved
Replace both windows on front of deck house.
Condition: Improper/Lack of Maintenance
Due 19 November 2008
Resolved 19 November 2008
Resolution: Replaced both windows on front of deck house.
Construction/Loadline › Structures › Superstructure
Issued 14 November 2008 Resolved
Mouse all sail rigging shackles.
Condition: Improper Installation
Due 19 November 2008
Resolved 19 November 2008
Resolution: Moused all sail rigging shackles.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 November 2008 Resolved
Repair/replace ladder rungs for ladder between the hulls, rungs are separating from side rail.
Condition: Improper/Lack of Maintenance
Due 19 November 2008
Resolved 19 November 2008
Resolution: Repaired ladder rungs for ladder between the hulls.
Construction/Loadline › Penetrations › Gasket
Issued 14 November 2008 Resolved
Replace the 5-inch plastic inspection ports (in both hulls) in the collision bulkheads with a bronze inspection port (plate and screw cap).
Condition: Improper Installation
Due 19 November 2008
Resolved 19 November 2008
Resolution: Replaced the 5-inch plastic inspection ports in the collision bulkheads with a bronze inspection port.
Construction/Loadline › Penetrations › Gasket
Issued 14 November 2008 Resolved
Install gaskets in both the port and starboard port lights (in way of the heads).
Condition: Improper/Lack of Maintenance
Due 19 November 2008
Resolved 19 November 2008
Resolution: Installed gaskets in both port and starboard port lights.
Construction/Loadline › Structures › Superstructure
Issued 14 November 2008 Resolved
Re-bed the following rail stanchions (counting from the bow) #5 port and #4&5 starboard.
Condition: Improper/Lack of Maintenance
Due 19 November 2008
Resolved 19 November 2008
Resolution: Re-beded rail stanchions #5 port and starboard and #4 starboard.
Construction/Loadline › Structures › Superstructure
Issued 14 November 2008 Resolved
In the passenger area, starboard side, renew top ladder rung. Re-bed the ladder connections to the main deck.
Condition: Improper/Lack of Maintenance
Due 19 November 2008
Resolved 19 November 2008
Resolution: Renewed top ladder rung and re-beded the ladder connections to the main deck.
Construction/Loadline › Structures › Superstructure
Issued 14 November 2008 Resolved
In the passenger area, portside, re-bed the ladder connection to the main deck.
Condition: Improper/Lack of Maintenance
Due 19 November 2008
Resolved 19 November 2008
Resolution: Re-beded the ladder connection to the main deck.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 14 November 2008 Resolved
Prove proper operation of all bilge alarms.
Due 19 November 2008
Resolved 19 November 2008
Resolution: Proved proper operation of all bilge alarms.
Construction/Loadline › Structures › Superstructure
Issued 14 November 2008 Resolved
Re-bed the bemine hallear clip starboard side of mast.
Condition: Improper/Lack of Maintenance
Due 19 November 2008
Resolved 19 November 2008
Resolution: Re-beded the bemine hallear clip starboard side of mast.
Engineering › Steering Gear System › Rudder
Issued 14 November 2008 Resolved
Port rudder, outboard side, grind and renew the fiber glass. The FRP has delaminated.
Condition: Unknown
Due 19 November 2008
Resolved 19 November 2008
Resolution: Repaired delaminated fiber glass areas.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 5 February 2008 Resolved
Provide three B2 Fire extinguishers onboard vessel. Vessel currently has one B1 and one B2.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2008
Resolution: Corrected.
Lifesaving › Lifefloat › Serviceable
Issued 5 February 2008 Resolved
Replace or repair 02 lifefloats.
Action required: 705 - Other - as specified
Resolved 6 September 2010
Fire Fighting › Fire Bucket › Availability
Issued 5 February 2008 Resolved
Provide 1 missing fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2008
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 5 February 2008 Resolved
Renew hydrostatic release and battery on epirb. Vessel restricted to 3 miles from shore until item cleared.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2008
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 5 February 2008 Resolved
Repair or replace 11 adult and 3 child lifejacket. Passenger count reduced to 20 untill cleared.
Action required: 705 - Other - as specified
Resolved 7 February 2008
Resolution: Corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 February 2008 Resolved
Make proper repairs to inoperable lifefloat light. (restricted from night ops untill cleared)
Action required: 705 - Other - as specified
Due 17 February 2008
Resolved 7 February 2008
Resolution: Corrected.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 February 2008 Resolved
Repair or replace compass.
Action required: 705 - Other - as specified
Due 12 February 2008
Resolved 7 February 2008
Resolution: Corrected.
Construction/Loadline › Penetrations › Gasket
Issued 5 February 2008 Resolved
Make proper repairs to holes in bulkhead stbd side as discussed with vessel rep.
Action required: 705 - Other - as specified
Due 12 February 2008
Resolved 7 February 2008
Resolution: Repaired.
Engineering › Fuel Oil Service System › Filter
Issued 5 February 2008 Resolved
Provide 02 fuel filters onboard vessel.
Action required: 705 - Other - as specified
Due 12 February 2008
Resolved 7 February 2008
Resolution: Installed.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 5 February 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2008
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 February 2007 Resolved
Renew faded retroreflective tape on 10 adult lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2007
Navigation › Piloting/Steering › Marine Charts
Issued 7 February 2007 Resolved
Provide missing nav publication (US Coast Pilot, tidal tables, tidal current tables)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2007
Lifesaving › Buoyant Apparatus › Marking
Issued 7 February 2007 Resolved
Renew lifefloat vessel name, retrotape, and 1 light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2007
Fire Fighting › Fire Bucket › Availability
Issued 7 February 2007 Resolved
Provide 3 stenciled fire buckets with sufficient line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2007
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 7 February 2007 Resolved
Provide evidence of random drug testing program for all crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2007
Engineering › Bilge Water Management System › Pump
Issued 7 February 2007 Resolved
Repair stbd bilge pumps and alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 January 2006 Resolved
Ensure 1 Master and 2 Deck hands are properly enrolled in a chemical testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2006
Resolution: Corrected as per Maritime Consortium.
Construction/Loadline › Hull › Stiffener
Issued 16 November 2005 Resolved
Repair broke mast stringer to as original condition .
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2005
Resolved 23 November 2005
Construction/Loadline › Hull › Stringer
Issued 16 November 2005 Resolved
Provide medical report from injured crewmember stating if member fit for full duty.
Action required: 705 - Other - as specified
Resolved 23 November 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 November 2005 Resolved
Provide current rigging report attesting to good condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 June 2005 Resolved
Provide 2 new or serviced BII fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 December 2004 Resolved
CHANGE STENCILS ON ALL LIFEJACKET & LIFEFLOATS TO REFLECT VESSEL NAME CHANGE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2005
Resolved 21 December 2004
Engineering › Steering Gear System › Rudder Stock
Issued 8 December 2004 Resolved
REPAIR BOTH DELAMINATED RUDDERS TO AS NEW CONDITION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 December 2004
Resolved 21 December 2004
Engineering › Steering Gear System › Linkage
Issued 8 December 2004 Resolved
RENEW BROKEN PORT ENGINE CONTROL.
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 21 December 2004
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2004 Resolved
REPAIR 4 SMALL HOLES IN STBD INBOARD HULL & REMOVE SHEET METAL SCREWS
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 21 December 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 December 2004 Resolved
PROVIDE NAME CHANGE ON CERTIFICATE OF DOCUMENTATION.
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 21 December 2004
Lifesaving › Buoyant Apparatus
Issued 24 May 2004 Resolved
Provide one buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2004
Resolved 2 June 2004
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 24 May 2004 Resolved
Provide 10 adult size life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2004
Resolved 2 June 2004
Communications › Radio Communications
Issued 4 February 2003 Resolved
Replace battery in EPIRB or provide new EPIRB. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2003
Resolution: New EPIRB installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 4 February 2003 Resolved
Replace Type B-I fire extinguisher at helm station and Type B-II fire extinguisher in port side head compartment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2003
Resolution: New extinguishers installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 February 2003 Resolved
Replace line on ring buoy.
Condition: Unknown
Due 3 March 2003
Resolved 6 February 2003
Resolution: Line replaced.
Lifesaving › Buoyant Apparatus
Issued 4 February 2003 Resolved
Replace water light and line on the #1 Life Float.
Condition: Unknown
Due 3 March 2003
Resolved 6 February 2003
Resolution: New light and line installed.
Documentation › Certificates/Documents
Issued 4 February 2003 Resolved
Proved onboard current Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Resolution: COD placed onboard.
Documentation › Certificates/Documents
Issued 4 February 2003 Resolved
Provide onboard current COI. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Resolution: Current COI placed onboard.
Navigation › Piloting/Steering
Issued 4 February 2003 Resolved
Provide onboard an up to date chart of area transited, tide tables, current tables, Coast Guard light list and coast pilot as required by 46 CFR 184.420 LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Due 3 March 2003
Resolved 28 February 2003
Resolution: Pubs and chart provided onboard.
Engineering › Bilge Water Management System
Issued 23 October 2002 Resolved
Replace high level sensor for bilge alarm in #1 starboard compartment and prove proper operation of alarm. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2002
Resolved 30 October 2002
Resolution: High level sensor replaced and tested.
Engineering › Bilge Water Management System
Issued 23 October 2002 Resolved
Replace high level sensor for bilge alarm in #2 port and starboard compartment (head compartment) and prove proper operation of alarm. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2002
Resolution: Float switches replaced and alarms tested.
Engineering › Bilge Water Management System
Issued 23 October 2002 Resolved
Secure bilge pumps in #2 port and starboard compartments (head compartment) and ensure discharge hoses are securely attached. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2002
Resolved 30 October 2002
Resolution: Bilge pump and hose secured and tested.
Engineering › Bilge Water Management System
Issued 23 October 2002 Resolved
Lower the high level bilge alarm sensors in both port and starboard rudder compartments to no more than 8 inches above bottom of bilge. (Currently mounted approx. 2 feet from bottom of bilge.) LEGACY COMPONENT DESC: Interface Detector
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2002
Resolution: Sensors lowered and tested.
Engineering › Steering Gear System
Issued 23 October 2002 Resolved
Replace/repair both rudders due to damage and water intrusion. LEGACY COMPONENT DESC: Rudder
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2002
Resolution: Both rudders repaired.
Engineering › Non-conventional Propulsion/Steering
Issued 23 October 2002 Resolved
Make repairs to fractures in way of the mounts/pivots for the engine sled. LEGACY COMPONENT DESC: Base (cycloidal)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2002
Resolution: Repairs made to fractures. Fractures were only surface cracks in fairing compund. No structural damage noted.
Communications › Radio Communications
Issued 26 February 2002 Resolved
SJ01: Replace expired hydrostatic release on EPIRB. LEGACY COMPONENT DESC: EPIRB Hydrostatic release
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2002
Resolution: New hydrostatic release installed in EPIRB holder.
Lifesaving › Buoyant Apparatus
Issued 26 February 2002 Resolved
SJ02: Renew or replace outboard life float that has torn/dry rotted lifeline supports. LEGACY COMPONENT DESC: Lifeline supports/straps
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2002
Resolution: Old life float repalced with new one of same capacity.
Lifesaving › Buoyant Apparatus
Issued 26 February 2002 Resolved
SJ03: Re-stencil inboard life float with vessels name and capacity. 46 CFR 185.604 LEGACY COMPONENT DESC: Markings on life floats
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2002
Resolved 27 February 2002
Resolution: Life float re-stenciled with vsl name and capacity.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 26 February 2002 Resolved
SJ04: Provide proof of annual servicing of all portable fire extinguishers onboard in accordance with Chapter 4 of NFPA 10. 46 CFR 176.810 . LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 2 April 2002
Resolved 19 April 2002
Resolution: Fire extiguishers serviced.
Construction/Loadline › Structures
Issued 26 February 2002 Resolved
SJ05: Make permanent repairs to both port and starboard dagger board control mounting blocks. LEGACY COMPONENT DESC: Dagger board control mounting blocks
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2002
Resolved 14 March 2002
Resolution: Blocks repaired with epoxy and wood screws.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 February 2002 Resolved
SJ06: Make permanent repairs to the mounts of both the port and starboard #1 stanchions and the #5 port stanchion supporting the safety railing. These stanchions are pulling out of the deck and/or missing fasteners. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2002
Resolved 19 April 2002
Resolution: Backing block replaced on the #1 port stanchion and fasteners on the #1 stbd and #5 port replaced and tightened.
Navigation › Piloting/Steering
Issued 26 February 2002 Resolved
SJ07: Place onboard, the charts and nautical publications as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 2 April 2002
Resolved 19 April 2002
Resolution: 2002 publication (REEDS Almanac) placed on board.
Lifesaving
Issued 23 February 2000 Resolved
REPLACE WASTED PENDANTS ON LIFE FLOATS. 46 CFR 180.175
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 23 February 2000 Resolved
REPLACE DETEORATED 3 FT LANYARD ON RING LIFE BUOY. 46 CFR 181.70
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 23 February 2000 Resolved
PROVIDE 200 MM/8 INCH BELL. 33 CFR 86
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Navigation
Issued 23 February 2000 Resolved
PROVIDE CHART FOR THE AREA TRANSITTED. 46 CFR 184.420
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Documentation
Issued 23 February 2000 Resolved
PRODUCE SIMPLE WASTE MANAGEMENT PLAN. (EXAMPLE WMP'S PROVIDED TO OWN/OP) - 33 CFR 151.57
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 23 February 2000 Resolved
REPLACE WASTED RETRO-REFLECTIVE TAPE ON (8) ADULT LIFE JACKETS; CLEAN ALL CHILD LIFE JACKETS; CLEAN EXCESSIVE MILDEW ON (12) ADULT LIFE JACKETS; STENCIL VSL NAME ON (2) LIFE JACKETS. 46 CFR 185.604
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Documentation
Issued 23 February 2000 Resolved
PRODUCE BRIDGE LOG TO RECORD "ABANDON SHIP/FIRE/EMER STEERING/MAN OVERBOARDDRILLS". 46 CFR185.520/524._x001C_
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Documentation
Issued 23 February 2000 Resolved
PRODUCE TRAINING LOG TO RECORD INITIAL AND REQUIRED 3 MONTH TRAINING GIVEN TO CREWMEMBERS. 46 CFR 185.420
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 23 February 2000 Resolved
PROVIDE EVIDENCE OF DATE OF PURCHASE OF HYDROSTATIC RELEASE AND PUNCH MARK DATES ACCORDINGLY ON RELEASE. 46 CFR 180.64
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Electrical
Issued 3 March 1999 Resolved
PRIOR TO 30MAR99 PROVIDE PROPER WIRE CONNECTORS FOR LIGHT WIRING LOCATED UNDER PORT SIDE PANTOON ENTRANCE/LADDER.
Condition: Unknown
Due 5 March 1999
Resolved 17 May 1999
Documentation
Issued 3 March 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 18 November 1998 Resolved
RENEW BOARDING PLATFORM SUSPENSION LINE
Condition: Unknown
Due 18 November 1998
Resolved 19 November 1998
Construction/Loadline
Issued 18 November 1998 Resolved
PROVIDE REPAIR PROPOSAL FOR CRACKS IN PIVOT BLOCKS OF ENGINE SLED, STBD SIDE, BOTH BLOCKS. PROVIDE CONSTRUCTION DRAWINGS OF THIS ASSEMBLY TO CG INSPECTOR.
Condition: Unknown
Due 23 December 1998
Resolved 4 January 1999
Documentation
Issued 16 October 1998 Resolved
Prior to 01NOV98 properly post radio operator instructions as required.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 16 October 1998 Resolved
Prior to 01NOV98 post lifejacket donning instructions.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 16 October 1998 Resolved
Prior to 01NOV98 provide suitable lifesaving equipment (i/e proper lifejacket and rescue line) as per item #4 of emergency procedures to rescue a man overboard.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 16 October 1998 Resolved
Prior to 01NOV98 properly post emergency instructions for fire and man overboard evolutions.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 15 April 1998 Resolved
REDESIGN SUPPORT/HOLDING BRACKETS FOR TWO BUOYANT APPARATUS TO MAKE FLOAT FREE AND INSTALL SAME. (MUST CLEAR RUDDER TILLER ARM FOR PROPER FLOAT FREE ARRANGEMENT).
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Lifesaving
Issued 26 February 1997 Resolved
PROVIDE TWO (2) FOUR (4) FOOT LONG PADDLES FOR EACH LIFE FLOAT. EIGHT (8) TOTAL PADDLES.
Condition: Unknown
Due 26 March 1997
Resolved 17 April 1997
Lifesaving
Issued 26 February 1997 Resolved
PROVIDE BRIGHT COLOR PORTABLE WATERTIGHT CONTAINER FOR STORAGE OF DISTRESS SIGNALS STENCILED "DISTRESS SIGNALS".
Condition: Unknown
Due 26 March 1997
Resolved 17 April 1997
Lifesaving
Issued 26 February 1997 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 26 March 1997
Resolved 10 April 1997
Documentation
Issued 26 February 1997 Resolved
OBTAIN AND MAINTAIN VESSEL LOGBOOK AS PER 46 C.F.R 185.524.
Condition: Unknown
Due 26 March 1997
Resolved 10 April 1997
Lifesaving
Issued 26 February 1997 Resolved
RENEW PAINTER ON PORT SIDE LIFE FLOAT.
Condition: Unknown
Due 26 March 1997
Resolved 10 April 1997
Lifesaving
Issued 26 February 1997 Resolved
RENEW RETRO REFECTIVE TAPE ON FIVE(5) CHILDRENS AND FIVE(5) ADULT LIFE JACKETS.
Condition: Unknown
Due 26 March 1997
Resolved 10 April 1997
Deck/Cargo
Issued 26 February 1997 Resolved
RENEW LINE TO BOOM PEVENTER.
Condition: Unknown
Due 26 March 1997
Resolved 10 April 1997
Documentation
Issued 26 February 1997 Resolved
PROVIDE ORIGINAL DOCUMENTS AND CERTIFICATES AND MAINTAIN ONBOARD VESSEL. (STABILITY LETTER, FCC SAFETY, FCC STATION LICENSE, COI)
Condition: Unknown
Due 26 March 1997
Resolved 17 April 1997
Electrical
Issued 26 February 1997 Resolved
PROVIDE TWO (2) OPERABLE PORTABLE BATTERY LIGHTS.
Condition: Unknown
Due 26 March 1997
Resolved 10 April 1997
Lifesaving
Issued 26 February 1997 Resolved
NO LATER THAN 11MAR97, INSTALL ON BOARD IN A FLOAT FREE ARRANGEMENT, A FCC ACCEPTED, CATAGORY 1, 406 MHz EPIRB.
Condition: Unknown
Due 11 March 1997
Resolved 10 April 1997
Construction/Loadline
Issued 26 February 1997 Resolved
INVESTIGATE FRACTURE AT BASE OF OUTBOARD SLED.
Condition: Unknown
Due 26 March 1997
Resolved 17 April 1997
Documentation
Issued 14 November 1996 Resolved
OBTAIN VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 22 December 1996
Resolved 19 February 1997
Lifesaving
Issued 4 March 1996 Resolved
INSTALL WEAK LINK ON PORT SIDE LIFEFLOAT ARRANGEMENT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Documentation
Issued 4 March 1996 Resolved
Provide the Coast Guard with the companies written employee pre-employment and random drug testing program in accordance with Title 46 Code of FederalRegulations Part 16.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Construction/Loadline
Issued 7 December 1995 Resolved
PROPERLY REPAIR HAIR LINE STRESS FRACTURE IN THE PORT AFT COMPARTMENT; PORTSIDE DECK.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Lifesaving
Issued 6 March 1995 Resolved
PROCURE AND INSTALL A WATERLIGHT ON EACH OF THE AFT TWO BUOYANT APPARATUS.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Documentation
Issued 6 March 1995 Resolved
PROVIDE COPY OF FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Lifesaving
Issued 6 March 1995 Resolved
REPLACE BATTERIES ON LIFE JACKET LIGHTS AS NECESSARY.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Lifesaving
Issued 24 March 1993 Resolved
PLACE ON BOARD AN APPROVED 406 EPIRB AND UPDATE VESSEL'S RADIO STATION LICENSE TO REFLECT THE ADDED EQUIPMENT.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Lifesaving
Issued 24 March 1993 Resolved
PROVIDE APPROVED LIGHTS FOR ALL LIFE JACKETS.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993

Casualty record · 1

1 April 2012Routine · role: Involved in a Marine Casualty · activity 4282772
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.