Records from 1992 to 2012. Most recent: inspection, 27 February 2012.
Inspection history · 28
27 February 2012
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 4250409
26 February 2012
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4252015
12 July 2011
PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4077787
11 July 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4073764
11 July 2011
ISPS I Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4079017
22 February 2010
PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3679285
14 July 2009
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3519281
23 October 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2516813
5 July 2005
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2411175
18 April 2005
Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2336220
1 September 2004
PII Safety Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2183502
1 July 2004
ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2117386
6 January 2004
Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1983512
13 May 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1793325
9 May 2003
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1790038
18 April 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1605703
23 April 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 289059
10 April 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 276576
29 August 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 419796
10 February 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412873
31 March 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 402010
28 March 1996
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 390027
17 October 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 383750
28 February 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 493019
3 August 1993
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 360025
28 January 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 355846
11 June 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 351400
8 March 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 349559
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Vent
Issued 27 February 2012
No resolution recorded
SHIP'S BOILER IS NOT ADEQUATE TO SUPPLY ALL ITS INTENDED FUNCTIONS ABOARD THE SHIP. THE BOILER SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH IT IS INTENDED.
SOLAS 97 CONS. ED. CH. II-1/26.1
Action required: 705 - Other - as specified
Engineering › Steam Boiler (auxiliary/waste heat) › Firebox Brick
Issued 12 July 2011
Resolved
0999, The machinery, and boilers shall be so installed and protected as to reduce to a minimum any danger to persons onboard, due regard being paid to hot surfaces and other hazards. Boiler fire brick is failing in way of boiler exhaust piping, exhaust discharge pipe is glowing red. SOLAS 74(04) CHII-1 Reg. 26.1 17a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2011
Resolved 15 July 2011
Resolution: Removed and repaired fire brick
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 July 2011
Resolved
1020, Suitable instructions and components spares for testing and maintenance shall be provided, for fixed fire detection and fire alarm systems. 01 Smoke detector is missing above the #2 main air compressor, no spares are onboard. Eng. Dept uses a coffee can with holes punched in it and a smoldering rag to test the system. SOLAS 74(97) CHII-2 Reg 13.1.12 17a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2011
Resolved 15 July 2011
Resolution: Crew now has canned smoke onboard to use for testing. 01 Smoke detector fitted above #2 main air compressor, and vessel now has spares onboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 July 2011
Resolved
1730, Any ship of 400GT and above but less than 10,000GT shall be fitted with oil filtering equipment complying with paragraph 6 of this regulation. OWS discharge piping has hole in it and could not be properly tested. MARPOL Annex I CH3 Reg 14.1 17a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2011
Resolved 15 July 2011
Resolution: OWS pipe with hole replaced
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 July 2011
Resolved
0715, (Heat) Detectors shall be located for optimum performance. Forward portside work shop in the engine room, heat detector has a storage shelf built under it. SOLAS 74(97) CHII-2 Reg13.2.4 70c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 July 2011
Resolved 15 July 2011
Resolution: Heat detector moved approx 9 inches, so that it is not obstructed by shelf
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 12 July 2011
Resolved
2120, Vessel shall carry a Garbage Management plan which the crew shall follow. Vessel is not logging the use of the incinerator. MARPOL Annex V Reg 9(2). 70c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 July 2011
Resolved 15 July 2011
Resolution: Verified latest entries in garbage record book. Vessel offloaded multiple garbage bags while in port. Spoke with Captain about requirement to use book anytime that incenerator is used.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 July 2011
Resolved
0950, All Electrical apparatus shall be so constructed and so installed as to not cause injury when handled or touched in the normal manner. There are 04 lighting fixtures without bulb covers behind the main switchboard in the engine control room. SOLAS 74(04) CHII-1 Reg 45.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 July 2011
Resolved 15 July 2011
Resolution: Bulbs are now shielded
Navigation › Piloting/Steering › Marine Charts
Issued 18 April 2002
Resolved
Missing Nautical chart 12312
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Mso Philadelphia verfied chart was onboard.
Navigation
Issued 8 March 1992
Resolved
U.S. CHART 12313 USED BY THE VESSEL WAS NOT CORRECTED TO THE LATEST NOTICE TO MARINERS. THERE WAS NO FOREIGN EQUIVALENT ON BOARD.
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992