STEEL TITAN

STEEL TITAN is a 1991 freight ship. The Coast Guard has recorded 46 inspections since 1993, most recently in June 2014, along with 20 deficiencies and 8 operational controls.

Records from 1993 to 2014. Most recent: inspection, 19 June 2014.

Built
1991
Last inspected
19 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8905828 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
371157
Flag
LIBERIA
—
Maury page id
psix-371157

Inspections, by type

…with no type recorded23
Years with a record 19 calendar years (1993–2014)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it22519 - Convention (Subpart B), Net Ton
77209 - Displacement, Ton
65433 - Dead Weight, Ton
36448 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 46

19 June 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4893105
13 May 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4857150
13 May 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4858673
13 May 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4859489
5 May 2014 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4844147
5 August 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4106223
28 July 2011 Ballast Water Examination · Deficiency Check · ISPS III Exam · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4088390
27 July 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4096232
10 December 2010 Ballast Water Examination · ISPS III Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3903737
9 December 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3907653
15 March 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3689397
12 December 2009 ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3649071
6 July 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3526310
14 October 2008 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3333686
29 September 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3334612
19 September 2008 ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3328018
17 September 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3327159
27 November 2007 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3102972
15 November 2007 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3099284
28 February 2007 MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2872027
22 February 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2876115
15 March 2006 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2603097
14 March 2006 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2602550
7 March 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2598725
13 June 2005 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2388783
1 July 2004 ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2117429
1 July 2004 MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2117482
29 June 2004 ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2114873
29 June 2004 Ballast Water Examination · PII Safety Exam · ILO-147 Exam · MARPOL Annex II Examination · MARPOL Annex V Examination · STCW 95 Exam · Loadline Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2114935
27 June 2004 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2113423
4 February 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1739964
27 January 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1736993
21 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1733483
15 February 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486817
12 December 2001 Passenger/Freight Vessel Examination
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1474879
23 September 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 282305
20 January 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 273628
30 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 414347
18 December 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 410716
3 April 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 402432
19 January 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 399817
3 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 386462
3 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 716306
11 January 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 374186
16 July 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 368540
17 January 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 355676

Deficiency record · 20

Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 13 May 2014 Resolved
The vessel experienced a failure of the digital governor system console.
Action required: 705 - Other - as specified
Due 13 May 2014
Resolved 13 May 2014
Resolution: Received, reviewed and accepted class report satifying the requirements
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 28 July 2011 Resolved
2100 - THE CONDITION OF THE SHIP AND EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTION. THE INCINERATOR WAS FOUND TO BE INOPERABLE. - MARPOL ANNEX I REG. 6.4.1 - 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2011
Fire Fighting › Portable Foam Applicators › General
Issued 28 July 2011 Resolved
0730 - THERE SHALL BE IN EACH BOILER ROOM AT LEAST ONE SET OF PORTABLE FOAM APPLICATOR UNITS. THE VESSEL DOES NOT HAVE A PORTABLE FOAM APPLICATOR ON BOARD. - 74 SOLAS (97 CON) II-2 / 7.1.2 - 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2011
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 July 2011 Resolved
0700 THE FIRE CONTROL PLAN SHALL SHOW THE LOCATION OF FIRE EXTINGUISHING APPLIANCES. THE FIRE CONTROL PLAN DOES NOT SHOW THE LOCATION OF THE PORTABLE FOAM APPLICATOR. - 74 SOLAS (97 CON) II-2 / 20.1 - 70AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 July 2011
Engineering › Steering Gear System › Pump
Issued 28 July 2011 Resolved
1510 - THE MAIN STEERING GEAR SHALL BE CAPABLE OF PUTTING THE RUDDER OVER FROM 35DEG ON ONE SIDE TO 35DEG ON THE OTHER SIDE. WHEN THE #1 PUMP IS OPERATED THE RUDDER WILL ONLY GO OVER TO 33DEG STBD. - 74 SOLAS (97 CON) II-1 / 29.3.2 - 70AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 July 2011
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 December 2010 Resolved
1530 - Radar - Master notified Coast Guard that the X band radar was non-operational. Vessel is to submit a technician report or classification society report attesting to satisfactory operation of the radar. -SOLAS 2009 V/19.2.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. That a engineer form Electro-Tech, Inc installed and programmed. Engineer also tested the radar which was found to be properly working.
Engineering › Lubricating Oil Service System › Hose
Issued 15 March 2010 Resolved
Found numerous hydraulic leaks on the system that operates vessels hatches. Most notable is the forward starboard corner of cargo hold #1. SOLAS 2009 Ch. 1 Regulation 11
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2010
Resolution: Cargo hatch covers and hydraulic systems were found to be satisfactory to attending U.S Coast Guard Inspectors
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 12 December 2009 Resolved
The smoke extraction line for cargo hold #1 is leaking next to cargo hold #4 STBD side. This leak contaminates the cargo hold sample. Correct to the satisfaction of class. SOLAS 81 II/2/54.2.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2010
Resolution: Received class report attesting to removal of these line because the vessel is no longer authorized to carry dangerous goods, and is no longer required to have smoke extraction system.
Fire Fighting › Fire Main › Condition
Issued 12 December 2009 Resolved
The fire main expansion joint next to #3 cargo hold is leaking. Further deterioration at this joint could cause failure of fire line forward of cargo hold #3. Correct to the satisfaction of class. SOLAS 04 I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2010
Resolution: Received class report attesting to proper repair of fire main expansion joint.
Engineering › Fuel Oil Service System › Piping
Issued 12 December 2009 Resolved
The M/E #5 cylinder F/O distributor is leaking into a crew constructed drain pail. This poses a fire hazard. Correct to the satisfaction of class. SOLAS 81 II-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2010
Resolution: Received class report attesting to proper repair of F/O distributor.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 12 December 2009 Resolved
The M/E #3 cylinder is leaking cooling water at the O-ring liner at a rate of approx. 1 gal. per hour. Correct to the satisfaction of class. SOLAS 04 I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2010
Resolution: Recieved class report attesting to proper repair of cylinder.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 12 December 2009 Resolved
The vessel has not lowered the port side lifeboat in the water and maneuvered since 26 May 09. The vessel is required to do this every 03 months as required by SOLAS III. Correct prior to next port. SOLAS 04 III/19.3.3.3
Action required: 705 - Other - as specified
Resolved 18 May 2010
Resolution: Recieved class report attesting to satisfactory drills have been run.
Engineering › Steering Gear System › Starter
Issued 14 October 2008 Resolved
System 1 was tested in all modes of operation and it was also found that the NFU mode only worked when the system failure alarm was silenced. When the system was switched to System 1 from System 2 the rudder would swing to hard port or hard starboard with no helm input. Rectify prior to movement.
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 12 December 2009
Resolution: Steering gear was tested and found satisfactory on PII/ISPSII exam.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 27 November 2007 Resolved
Vessel master or Chief Engineer could not provide hydrostatic test for fuel and lube oil piping within the last 12 months. Vessel must conduct hydrostatic test prior to bunkering operations within US waters.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 November 2007
Resolved 28 November 2007
Resolution: Rcvd report from ARGO Marine Fire and Safety satisfying requirement.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 14 March 2006 Resolved
Vsl's AIS is not equipped with a pilot plug. 33 CFR 164.46d 70c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 March 2006
Resolved 28 February 2007
Resolution: Vessel''s AIS Pilot Plug was found to be operable.
Fire Fighting › Firemans Outfit
Issued 12 December 2001 Resolved
Firemans outfits are worn and need to be replaced. LEGACY COMPONENT DESC: Protective Clothing
Condition: Unknown
Due 12 January 2002
Resolved 15 February 2002
Resolution: RCVD RECEIPTS FOR THE FIREMANS OUTFITS, FROM BLUEWATER SHIPPING, AND CLEARED DEF''S.
Navigation › Piloting/Steering
Issued 12 December 2001 Resolved
Tidal Current Tables missing.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2001
Construction/Loadline
Issued 19 January 1997 Resolved
PROVIDE PROOF THAT CLASS SOCIETY (GL) WAS NOTIFIED OF THE REPAIRED FRACTURE THROUGH THE COMPRESSION BAR (4") ON THE NUMBER 5 HATCH COAMING (STBD SIDE). ILLC 66 ANNEX I.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Navigation
Issued 3 January 1996 Resolved
THE MAIN MARINE RADAR AND SECONDARY MARINE RADAR INOPERABLE._x001C_ (33 CFR 164.11(r)_x001C_
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Navigation
Issued 3 January 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.