Records from 2008 to 2021. Most recent: inspection, 6 December 2021.
Inspection history · 20
6 December 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7364939
23 September 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7319139
15 July 2020
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7008132
15 July 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7077165
4 February 2020
Hull Examination · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6902358
31 July 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6768469
15 May 2018
DAPI Audit · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6414288
15 January 2018
Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6331087
8 August 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6234054
26 May 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5887344
14 January 2016
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5797814
7 August 2015
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5208749
5 August 2014
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4944565
20 May 2014
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4862305
13 June 2012
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4318716
15 May 2012
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4312460
17 August 2011
Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4116703
29 July 2009
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3535469
28 April 2008
Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3202841
3 March 2008
Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3163271
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2020
No resolution recorded
Make vessel and all damaged rigging available for inspection.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020
No resolution recorded
Provide a repair plan for the mast and all damaged rigging.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2019
Resolved
Prove proper operation of high bilge alarms.
Action required: 10 - Deficiency Rectified
Due 31 July 2019
Resolved 31 July 2019
Resolution: Returned to vessel, alarms tested properly.
Engineering › Fuel Oil Service System › Hose
Issued 5 August 2014
Resolved
Provide proper fuel piping between fuel tank and engine IAW 46CFR182.455. If using entire lengths of flex hose, install IAW 46CFR182.720
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 September 2014
Resolution: Owner installed annealed tubing within 30" of engine.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 5 August 2014
Resolved
Provide conductor between flexible section of fuel fill pipe
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 September 2014
Resolution: A conductor was placed between flexible section of pipe to prevent static charge.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 5 August 2014
Resolved
Properly bond fuel tank to common ground
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 September 2014
Resolution: The fuel tank is properly bonded.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 August 2014
Resolved
Prove proper operation of forepeak high level alarm or remove
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 September 2014
Resolution: Witnessed proper operation of fore peak high level alarm
Stability › Incline Test › General
Issued 13 June 2012
Resolved
Current Stability Letter was issued by MSC and was conducted based on an AAWPP of 165 pounds. Reduced passengers from 25 to 21 and total persons from 30 to 26 using the weight ratio method (165 X 30 = 4950 lbs 4950/185 = 26.7 rounded down to 26 total persons)
Action required: 705 - Other - as specified
Due 21 July 2012
Resolved 13 September 2012
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 August 2011
Resolved
Prior to carrying passengers, make vessel available for Annual Exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2011
Resolved 18 August 2011
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 July 2009
Resolved
Label adult and child life jackets stowage and quantity IAW 46 CFR 180.78
Action required: 705 - Other - as specified
Resolved 9 September 2009
Resolution: O/O labeled adult and child life jacket stowage location IAW 46CFR180.78
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 July 2009
Resolved
Install divider for child and adult life jackets.
Action required: 705 - Other - as specified
Resolved 9 September 2009
Resolution: O/O installed divider for child and adult life jackets.
Lifesaving › Lifebuoys › Size
Issued 29 July 2009
Resolved
Replace 3 ring buoys with 24" CG approved ring buoys IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Resolved 9 September 2009
Resolution: O/O replaced 3 ring buoys with 24" CG approved buoys IAW 46CFR180.70
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 29 July 2009
Resolved
Label fuel shutoff handle.
Action required: 705 - Other - as specified
Resolved 9 September 2009
Resolution: O/O labeled fuel shutoff handle IAW 46CFR185.608